Bronkhorst®
Instruction Manual mini CORI-FLOW ML120
9.17.097G
8
Accuracy
The accuracy of a
mini CORI-FLOW
is either 0.2% reading for liquids or 0.5% reading for gases.
This specification is based on mass flow (e.g. g/h, kg/h, etc.). Using the instrument for measuring volume flows (e.g. l/h,
ml/min) will introduce an additional inaccuracy, based on the actual density measured by the instrument. In all instruments
capable of density measurement there will be an automatic adjustment for change in density.
CORI-FILL™
mini CORI-FLOW
instruments with firmware version 1.05g and up are equipped with
CORI-FILL™
technology, designed for
fast and highly accurate mass or volume batch dosing of liquids or gases. The internal batch dosing controller is optimized
for controlling a valve or a (gear) pump, to deliver an exact batch dose, independent of fluid properties, ambient
temperature and back pressure.
1.4
Calibration
The mini CORI-FLOW is factory calibrated. Bronkhorst certifies that the instrument meets the rated accuracy. Calibration is
performed using measurement standards traceable to the Dutch Metrology Institute (VSL). Calibration certificates are
included in the scope of delivery.
Periodical inspection, recalibration or verification of the accuracy may be subject to individual requirements of the end user.
Unless specified otherwise,
mini CORI-FLOW ML120
instruments are H
2
0 calibrated.
1.5
Maintenance
No regular maintenance is required if the mini CORI-FLOW is operated properly, with clean media, compatible with the
wetted materials, avoiding pressure and thermal shocks and vibrations. Units may be purged with a clean, dry and inert gas
or a non-aggressive and non-corrosive solvent.
In case of severe contamination, cleaning of the inside of the instrument and of the valve orifice (if applicable) may be
required.
Inexpertly servicing instruments can lead to serious personal injury and/or damage to the instrument or the system it is
used in. Therefore, servicing must be performed by trained and qualified personnel. Contact Bronkhorst for information
about cleaning and calibration. Bronkhorst has a trained staff available.
1.6
Other documents
Basic instructions
Dimensional drawings
Document 9.17.093
Quick installation guide
mini CORI-FLOW ML120
Document 7.05.925
Dimensional drawing
mini CORI-FLOW ML120
Advanced instructions
Hook-up diagrams
Document 9.17.024
Instruction manual FLOW-BUS interface
Document 9.16.132
Hook-up diagram ML Series instruments RS232 and Analog
Document 9.17.025
Instruction manual PROFIBUS DP interface
Document 9.16.133
Hook-up diagram ML Series instruments FLOW-BUS
Document 9.17.026
Instruction manual DeviceNet™ interface
Document 9.16.134
Hook-up diagram ML Series instruments PROFIBUS DP
Document 9.17.027
Instruction manual RS232 interface
Document 9.16.135
Hook-up diagram ML Series instruments DeviceNet™
Document 9.17.035
Instruction manual Modbus interface
Document 9.16.136
Hook-up diagram ML Series instruments Modbus
Document 9.17.063
Instruction manual EtherCAT® interface
Document 9.16.137
Hook-up diagram ML Series instruments EtherCAT®