P.7

Tips on replacing the filter

To review the usage status of the filters at any time, 
press and hold the Child Lock button when the child 
lock is turned on. The accumulated number of hours 
the filters have been in use will display for 10 seconds.

When filter usage reaches 2000, the replacement filter 
icon will illuminate. 

Check the High Efficiency Antiviral Air Filter. If it is 
white or light grey, you can reuse it for another 2000 
hours. If it is dark grey or black, you need to replace it.

Follow the guidelines for filter cleaning or filter 
replacement.

To reset the timer, press and hold the Timer button for 
3 seconds.

Filter installation order

1. Nanocrystalline Filter
2. High Efficiency   
    Antiviral Air Filter  
    with Pre-Filter

1

2

Steps to replace the filter

After replacing the filter, turn o

 the filter indicator.

1. Open the front panel and 

  remove the existing filters

2. Insert the Nanocrystalline 
    Filter

3. Insert the High    
    Efficiency Antiviral  
    Air Filter with Pre-Filter 

4. Insert the front 

  panel and the filter 

  is successfully 
 replaced

1. Pre-Filter: captures hair, fiber, large particles, dander, etc., can be vacuumed and reused.

2. High Efficiency Antiviral Air Filter: This filter is an H12 HEPA Grade filter, good at capturing small particles. 

It has low penetration, large capacity for holding dust, high clean air delivery rate can e

ectively filter 

smoke and dust, especially for PM2.5, e

ciently filtering particles as small as 0.01μm. The filter is coated 

with a proprietary patent-pending formula that can effectively kill human coronavirus, general virus, 
bacteria and mold.

3. Nanocrystalline Filter: Sepiolite, diatomaceous earth, and other natural rare non-metallic minerals are 

  used to make nanocrystalline materials which clear harmful gases, formaldehyde, benzene, VOC and 

  other smelly pollutants. The nanocrystalline materials have many pores, good at absorbing nanoparticles, 

  such as formaldehyde, ammonia, and benzene (between 0.4-0.62 nanometers). As these compounds 

  are nano-sized polar molecules, they can be quickly absorbed.

4

. UV light: UV lamp helps to destroy virus and bacteria inside the machine.

5

. Plasma purification: The positive and negative ions generated by the plasma generator neutralize in the 

  air and produce huge energy, which results in the change of the microorganism structure around or the 
  conversion of energy, thereby destroying the microorganisms. As the number of negative ions is greater 

  than that of positive ions, excess negative ions are still floating in the air, which can remove smoke, dust, 

  smell, and improve air quality and health.

AIR PURIFYING FUNCTIONS

Summary of Contents for APP60

Page 1: ...Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 2: ...er and Accessories Product Features QuickStart Guide Precautions Operating Instructions Air Purifying Functions Technical Specifications Cleaning and Maintenance Troubleshooting Warranty 02 03 04 05 06 07 08 08 09 10 P 1 ...

Page 3: ...nit User Manual P 2 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 4: ... FEATURES Air Quality Indicator Touch Button Controller Carry Handle Sensor Door Latch Power Cord Port Motor Mount Magnet Front Panel P 3 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter ...

Page 5: ...rical outlet 9 Press on off button to switch on the air purifier 1 Carefully unpack your air purifier 2 Remove the front panel 3 Remove filters from protective plastic wrap 6 Insert the front panel P 4 5 Insert the High Efficiency Antiviral Air Filter with Pre Filter 4 Insert the Nanocrystalline Filter ...

Page 6: ...Otherwise chemicals will accumulate inside the machine and affect your health Do not use in places with oily residues smoke or fumes such as the kitchen to prevent damage to the product The appliance shall not be used as an exhaust fan When used in the same space with combustion devices make sure the room is well ventilated to prevent carbon monoxide poisoning as the appliance does not remove carbo...

Page 7: ...V 1 Touch the UV button to turn on off the UV light Switch on plasma 1 Touch the Plasma button turn on off the plasma function Use sleep mode 1 Touch the Sleep button to enter sleep mode The air quality indicator will be dimmed All the light indicators will be off except the sleep indicator 2 The appliance operates under speed 1 in sleep mode Disable sleep mode and return to previous setting by touc...

Page 8: ...HEPA Grade filter good at capturing small particles It has low penetration large capacity for holding dust high clean air delivery rate can effectively filter smoke and dust especially for PM2 5 efficiently filtering particles as small as 0 01μm The filter is coated with a proprietary patent pending formula that can effectively kill human coronavirus general virus bacteria and mold 3 Nanocrystalline Fi...

Page 9: ...lluminate In extremely poor air quality it may be time to change the filters but often cleaning the air filters and machine will suffice Each layer of the filter can be used for about 6 8 months Clean the filters regularly to ensure best performance Pre Filter clean with vacuum cleaner Nanocrystalline Filter expose to sunlight for 1 3 hours every 2 months P 8 Product Name Model Voltage Frequency P...

Page 10: ...sor and clean the lens with a soft cloth 1 Check if the filter is expired or has adsorbed pollutants with bad smell 2 The Nanocrystalline filter can be reused after exposure to sunlight If the problem persists change the filter Use a vacuum cleaner to clean the pre filter If the problem persists change the filter The appliance may be placed in the wrong place that prevents pollutants from being absorbe...

Page 11: ...ods etc Damage or loss resulting from negligent or improper installation including installation of a unit in a harsh or excessively hazardous environment Damage or loss resulting from removal improper repair modification of the product or improper maintenance including damage caused by improper cleaning and exchanging of filters Damage or loss resulting from acts which are not the fault of BRONDEL...