background image

TECHNICAL SPECIFICATIONS

CLEANING AND MAINTENANCE

Unit: Please regularly wipe the surface of 

the machine with a soft cloth moistened 
with clean water and detergent and clean 
the air inlet and outlet with a brush.

Sensor Cleaning: Regularly clean the lens of the sensor 
and the surface of the sensor with a moist cotton swab, 
and then use a dry cotton swab to remove any moisture 
left on the sensor.

Filter Replacement: A built-in program notifies when the filter needs replacement. When usage reaches 
2000 hours, the filter replacement indicator icon will illuminate.
In extremely poor air quality, it may be time to change the filters, but often cleaning the air filters and 
machine will suffice. Each layer of the filter can be used for about 6-8 months. Clean the filters regularly 
to ensure best performance. 
Pre-Filter: clean with vacuum cleaner
Nanocrystalline Filter: expose to sunlight for 1-3 hours every 2 months

P.8

Product Name

Model

Voltage

Frequency

Power

CADR

Filtration grade

Room Coverage

Casing Material

Airflow

Dimension

Weight

Sensor Type

Max. Noise

Type

Brondell Pro Sanitizing Air Purifier with AG+ Technology by Aurabeat

P700BB, P7004C, APP60

110-120V

50Hz/60Hz

95W

221 

H12 HEPA Grade

538 Sq Ft

High Quality ABS

247.2 ft

3

/min (CFM)

24.7 in x 15.4 in x 8.3 in 

19.2 lbs.

PM2.5 Sensor

≤62dB

Specifications

Summary of Contents for APP60

Page 1: ...Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 2: ...er and Accessories Product Features QuickStart Guide Precautions Operating Instructions Air Purifying Functions Technical Specifications Cleaning and Maintenance Troubleshooting Warranty 02 03 04 05 06 07 08 08 09 10 P 1 ...

Page 3: ...nit User Manual P 2 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 4: ... FEATURES Air Quality Indicator Touch Button Controller Carry Handle Sensor Door Latch Power Cord Port Motor Mount Magnet Front Panel P 3 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter ...

Page 5: ...rical outlet 9 Press on off button to switch on the air purifier 1 Carefully unpack your air purifier 2 Remove the front panel 3 Remove filters from protective plastic wrap 6 Insert the front panel P 4 5 Insert the High Efficiency Antiviral Air Filter with Pre Filter 4 Insert the Nanocrystalline Filter ...

Page 6: ...Otherwise chemicals will accumulate inside the machine and affect your health Do not use in places with oily residues smoke or fumes such as the kitchen to prevent damage to the product The appliance shall not be used as an exhaust fan When used in the same space with combustion devices make sure the room is well ventilated to prevent carbon monoxide poisoning as the appliance does not remove carbo...

Page 7: ...V 1 Touch the UV button to turn on off the UV light Switch on plasma 1 Touch the Plasma button turn on off the plasma function Use sleep mode 1 Touch the Sleep button to enter sleep mode The air quality indicator will be dimmed All the light indicators will be off except the sleep indicator 2 The appliance operates under speed 1 in sleep mode Disable sleep mode and return to previous setting by touc...

Page 8: ...HEPA Grade filter good at capturing small particles It has low penetration large capacity for holding dust high clean air delivery rate can effectively filter smoke and dust especially for PM2 5 efficiently filtering particles as small as 0 01μm The filter is coated with a proprietary patent pending formula that can effectively kill human coronavirus general virus bacteria and mold 3 Nanocrystalline Fi...

Page 9: ...lluminate In extremely poor air quality it may be time to change the filters but often cleaning the air filters and machine will suffice Each layer of the filter can be used for about 6 8 months Clean the filters regularly to ensure best performance Pre Filter clean with vacuum cleaner Nanocrystalline Filter expose to sunlight for 1 3 hours every 2 months P 8 Product Name Model Voltage Frequency P...

Page 10: ...sor and clean the lens with a soft cloth 1 Check if the filter is expired or has adsorbed pollutants with bad smell 2 The Nanocrystalline filter can be reused after exposure to sunlight If the problem persists change the filter Use a vacuum cleaner to clean the pre filter If the problem persists change the filter The appliance may be placed in the wrong place that prevents pollutants from being absorbe...

Page 11: ...ods etc Damage or loss resulting from negligent or improper installation including installation of a unit in a harsh or excessively hazardous environment Damage or loss resulting from removal improper repair modification of the product or improper maintenance including damage caused by improper cleaning and exchanging of filters Damage or loss resulting from acts which are not the fault of BRONDEL...

Reviews: