background image

OPERATING INSTRUCTIONS

SPEED

SPEED

TIMER

PM2.5

TIMER

SLEEP

CHILD

 LOCK

     UV

PLASMA

Switch on

Touch the power button to switch on the appliance.

After switching on, the light indicator is always on. When a corresponding function is used, the light indicator under 
the icon is always turned on. The area displaying “ — — —” 10s after switching on will show the PM2.5 value.

The appliance operates under the auto mode by default.

The airflow is adjusted according to PM2.5. Auto mode is set as follows:

PM2.5 Value

Air Quality Level

Air Quality Light Color

Airflow Level

10-79

Good

Green

1

80-199

Fair

Blue

2

Bad

Red

200-500

3

Set the timer

1. Touch the “Timer Button” repeatedly to choose the number of hours you want the appliance to operate 
  (1-12 hours) and the switch-o

 time. When the timer is on, the light indicator is on.

Use UV

1. Touch the "UV" button to turn on/off the UV light.

Switch on plasma

1. Touch the "Plasma" button turn on/o

 the plasma function.

Use sleep mode

1. Touch the "Sleep" button to enter sleep mode. The air quality indicator will be dimmed. All the light 
  indicators will be o

 except the sleep indicator. 

2. The appliance operates under speed 1 in sleep mode. Disable sleep mode and return to previous 
  setting by touching any button.

Set the child lock

1. Touch the "Child Lock" button to activate the lock function and all the other buttons will not be 
  responsive. Press and hold for 3 seconds to close.

2. When the child lock is not on, press and hold this button for 3 seconds to view the accumulated 

  usage time of the filter, displayed in the PM2.5 area. The filter indicator is on and the four-digit 

  number is displayed.

Changing fan speed

Touch the “Fan Speed" button repeatedly to disable auto mode and manually change the speed among 
three settings (speeds 1-3). You can reselect auto mode by touching the button after speed 3.

P.6

Summary of Contents for APP60

Page 1: ...Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 2: ...er and Accessories Product Features QuickStart Guide Precautions Operating Instructions Air Purifying Functions Technical Specifications Cleaning and Maintenance Troubleshooting Warranty 02 03 04 05 06 07 08 08 09 10 P 1 ...

Page 3: ...nit User Manual P 2 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter Pro Sanitizing Air Purifier with AG Technology by Aurabeat User Manual Please read this instruction manual carefully Please remove all the packaging material from the filters ...

Page 4: ... FEATURES Air Quality Indicator Touch Button Controller Carry Handle Sensor Door Latch Power Cord Port Motor Mount Magnet Front Panel P 3 Pre Filter High Efficiency Antiviral Air Filter Nanocrystalline Filter ...

Page 5: ...rical outlet 9 Press on off button to switch on the air purifier 1 Carefully unpack your air purifier 2 Remove the front panel 3 Remove filters from protective plastic wrap 6 Insert the front panel P 4 5 Insert the High Efficiency Antiviral Air Filter with Pre Filter 4 Insert the Nanocrystalline Filter ...

Page 6: ...Otherwise chemicals will accumulate inside the machine and affect your health Do not use in places with oily residues smoke or fumes such as the kitchen to prevent damage to the product The appliance shall not be used as an exhaust fan When used in the same space with combustion devices make sure the room is well ventilated to prevent carbon monoxide poisoning as the appliance does not remove carbo...

Page 7: ...V 1 Touch the UV button to turn on off the UV light Switch on plasma 1 Touch the Plasma button turn on off the plasma function Use sleep mode 1 Touch the Sleep button to enter sleep mode The air quality indicator will be dimmed All the light indicators will be off except the sleep indicator 2 The appliance operates under speed 1 in sleep mode Disable sleep mode and return to previous setting by touc...

Page 8: ...HEPA Grade filter good at capturing small particles It has low penetration large capacity for holding dust high clean air delivery rate can effectively filter smoke and dust especially for PM2 5 efficiently filtering particles as small as 0 01μm The filter is coated with a proprietary patent pending formula that can effectively kill human coronavirus general virus bacteria and mold 3 Nanocrystalline Fi...

Page 9: ...lluminate In extremely poor air quality it may be time to change the filters but often cleaning the air filters and machine will suffice Each layer of the filter can be used for about 6 8 months Clean the filters regularly to ensure best performance Pre Filter clean with vacuum cleaner Nanocrystalline Filter expose to sunlight for 1 3 hours every 2 months P 8 Product Name Model Voltage Frequency P...

Page 10: ...sor and clean the lens with a soft cloth 1 Check if the filter is expired or has adsorbed pollutants with bad smell 2 The Nanocrystalline filter can be reused after exposure to sunlight If the problem persists change the filter Use a vacuum cleaner to clean the pre filter If the problem persists change the filter The appliance may be placed in the wrong place that prevents pollutants from being absorbe...

Page 11: ...ods etc Damage or loss resulting from negligent or improper installation including installation of a unit in a harsh or excessively hazardous environment Damage or loss resulting from removal improper repair modification of the product or improper maintenance including damage caused by improper cleaning and exchanging of filters Damage or loss resulting from acts which are not the fault of BRONDEL...