background image

4

www.bromicheating.com

IMPORTANT NOTES AND WARNINGS

WARNING

Failure to follow the warnings and instructions in this manual could 
result in severe personal injury, death or property damage.  

• 

Installation and repair should be done by a qualified service 
person. The heater should be inspected before use and at 
least annually by a qualified service person.

• 

Do not use or store flammable materials near this appliance

• 

Do not spray aerosols or flammable materials in the vacinity of 
this appliance while it is in operation 

• 

Any guard or other protective device removed for servicing 
(conducted by an authorised person) must be replaced before 
operating the heater.

• 

Children and adults should be alerted to the hazards of high 
surface temperatures and should stay away to avoid burns or 
clothing ignition.

• 

Children should be carefully supervised when they are in the 
area of the heater.

• 

Clothing or other flammable materials should not be hung 
from the heater or placed on or near the heater.

• 

Do not perform maintenance until heater has been turned off, 
and heater temperature has cooled to room temperature.

• 

Do not expose the burner to water or moisture. The appliance 
must be protected from rain.

• 

Do not use the heater if any of these parts are exposed 
to water until the appliance is inspected or repaired by an 
authorised service person.

• 

The installer is to ensure that the requirements of the local 
authority, local gas fitting regulations, municipal building 
codes, and any other relevant statutory regulations are carried 
out.

• 

Certain materials or items, when stored under or near the 
appliance, will be subjected to radiant heat and could be 
seriously damaged. 

• 

The whole gas system, hose assembly, regulator, pipes, and 
burner should be inspected for damage and leaks before each 
use and at least annually by an authorized person for the life 
of the heater.

• 

The hose assembly must be replaced prior to the appliance 
being put into operation if there is evidence of excessive 
abrasion or wear, or if the hose is damaged. The replacement 
hose must be purchased from Bromic Heating Pty Ltd.

• 

All leak tests should be done with a soap solution. Never use 
an open flame to check for leaks.

• 

Do not use the heater until all connections have been leak 
tested by an authorised person.

• 

This radiant heater is NOT intended to be installed on 
recreational vehicles and/or boats.

• 

Improper installation, adjustment, or alteration can cause 
personal injury, property damage, or even death.

• 

Do not attempt to alter the unit in any manner.

• 

Do not paint any surface of the heater or top canopy reflector.

• 

Burner and circulation air passageways of the heater must be 
kept clean. Frequent cleaning may be required as necessary.

• 

Turn Gas Supply off when not in use.

• 

Check the heater immediately if any of the following occurs:

 

»

The heater does not reach temperature.

 

»

The burner makes popping noise during use (a 
slight noise is normal when the burner is ignited or 
extinguished). 

• 

This appliance is not intended for use by young or infirm 
persons unless they have been adequately supervised by a 

responsible person to ensure that they can use the appliance 
safely. 

• 

Check for damage to the appliance regularly. If damage to 
the appliance is suspected, discontinue use immediately and 
contact the supplier or qualified person for repair. 

• 

Avoid inhaling fumes emitted from the heater’s first 
use. Smoke and odour from the burning of oils used in 
manufacturing will appear. Both the smoke and odour will 
dissipate after approximately 30 minutes. 

• 

The pressure regulator and hose assembly supplied with the

        appliance must be used. Replacement regulator and hose     
        assemblies must be purchased from Bromic Heating Pty Ltd. 

• 

Storage of an appliance indoors is permissible only if the 
cylinder is disconnected and removed from the appliance. 

• 

A cylinder must be stored outdoors in a well-ventilated area 
out of the reach of children. A disconnected cylinder must 
have dust caps tightly installed and must not be stored in a 
building, garage or any other enclosed area. 

• 

Do not store a spare LP-gas cylinder under or near this 
appliance; 

• 

Never fill the cylinder beyond 80%  full

!

Summary of Contents for Tungsten Smart-Heat

Page 1: ... vicinity of this or any other appliance WARNING WARNING Improper installation adjustment alteration service or maintenance can cause property damage injury or death Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment from the ll your gas ly Do not store or use petrol or other flamable vapor and liquids in the vicinity of this or an...

Page 2: ...ion about the assembly operation and maintenance of TUNGSTEN Smart Heat Heaters Please pay close attention to the important safety information shown throughout this instruction manual Any safety information will be accompanied by the following safety alert symbols DANGER WARNING IMPORTANT READ THIS MANUAL CAREFULLY before installing or servicing this product Installation and repair should be done ...

Page 3: ...TION 6 PRODUCT FEATURES 6 INSTALLATION REQUIREMENTS 7 8 GAS REQUIREMENTS 7 INSTALLATION CLEARANCES 8 INSTALLATION INSTRUCTIONS 9 20 HEATER INSTALLATION INSTRUCTIONS 9 19 LEAKAGE TEST 20 OPERATING INSTRUCTIONS 21 TURNING THE APPLIANCE ON 21 TURNING THE APPLIANCE OFF 21 MAINTENANCE AND SERVICING 22 TROUBLE SHOOTING 23 APPENDIX A 24 26 ...

Page 4: ...of excessive abrasion or wear or if the hose is damaged The replacement hose must be purchased from Bromic Heating Pty Ltd All leak tests should be done with a soap solution Never use an open flame to check for leaks Do not use the heater until all connections have been leak tested by an authorised person This radiant heater is NOT intended to be installed on recreational vehicles and or boats Imp...

Page 5: ...r a protective cover This appliance shall only be used in an above ground open air situation with sufficient natural ventilation The heater must not be operated in any stagnant areas and should be positioned where any potential gas leakage and products of combustion are rapidly dispersed by wind and natural convection TUNGSTEN Smart Heat Ignition 1 5V repetitive spark ignitor Manufactured by BROMI...

Page 6: ...he areas of Aesthetic appeal Innovation Performance Flexibility Cost effectiveness For more detailed product information visit www bromicheating com GENERAL INFORMATION The TUNGSTEN Gas Patio Heaters are suitable for outdoor spaces In addition to the installation Instructions provided authorized installers must abide by local codes or in the absence of local codes with the National Fuel Gas Code A...

Page 7: ... is completely open ref Appendix A Example 4 and At least 30 of the remaining wall area is open and unrestricted ref Appendix A Example 4 Note The definition of outdoors is an above ground open air situation with natural ventilation without stagnant areas where gas leakage and products of combustion are rapidly dispersed by wind and natural convection GAS REQUIREMENTS TUNGSTEN Smart Heat LPG Model...

Page 8: ...ocations subject to rain Note Heater should be installed in such a way so as to allow adequate Clearance around air openings to combustion chamber Clearance from combustible material Provisions for accessibility and clearance for combustion and ventilating air supply INSTALLATION REQUIREMENTS CONTINUED IMPORTANT This appliance must only be used in a well ventilated area When selecting the installa...

Page 9: ...RUCTIONS CONTENTS PACKED IN 2 BOXES Box 1 Contents CONTENTS PACKED IN 2 BOXES Box 2 Contents Base Assembly Rear Arm Assembly x 2 Top Arms x 2 Top Flame Deflector Regulator Front Assembly Head Assembly AAA Battery Side Panels x 2 Rear Cover AAA ...

Page 10: ...TRUCTIONS CONTINUED 10 M8 x 45mm M8 x 16mm M5 x 8mm G8 x 8mm QTY 2 QTY 2 QTY 4 QTY 12 Supplied Fasteners Supplied Tools Tools Not Included M8 Hex Key Phillips head screw driver and Spray Bottle M8 x Washer QTY 4 M8 x 95mm QTY 4 M8 x 20mm QTY 4 ...

Page 11: ...NTINUED 10 STEP 1 Unpack boxes and place all items on a non abrasive surface STEP 2 Fasten rear arms to base using 2 x M8 20mm screws and the supplied M8 Hex Key STEP 3 Position front assembly and fasten using 2 x M8 20mm screws using supplied M8 Hex Key ...

Page 12: ...ONS CONTINUED 10 STEP 4 Secure the rear arms to front assembly using 2 x M8 x 16mm screws and supplied M8 Hex Key STEP 5 Secure the side panels to frame using 12 x G8 screws A Phillips screw driver is required for this step Repeat for opposite side ...

Page 13: ...the front panel to top arms using 4 x M5 screws and supplied M5 Hex Key STEP 7 Secure the top arms to lower arm slip joint using 2 x M8 x45 screws and supplied M8 Hex Key Note The joint between the lower and upper arms is firm to ensure rigidily and stability of the product To engage slowly lever the two sections together using some force and push down fully L R ...

Page 14: ...n a non abrasive surface as shown Two people are required for this step NON ABRASIVE SURFACE STEP 9 Feed gas hose through arm slot and push through until it reaches slot in bottom arm Keep feeding hose until all slack is taken up INSTALLATION INSTRUCTIONS CONTINUED ...

Page 15: ...CONTINUED STEP 10 Secure the heater head to arms using 4 x M8 screws and supplied washers with M8 Hex Key CONTINUED STEP 13 Return heater to upright position Two people are required for this step NON ABRASIVE SURFACE INSTALLATION INSTRUCTIONS CONTINUED ...

Page 16: ...bottle STEP 15 Place gas bottle into lower enclosure and fasten strap tightly STEP 17 Lower gas bottle bracket into position STEP 16 Pull sleeve back on regulator connector insert hose fitting release sleeve on regulator connector INSTALLATION INSTRUCTIONS CONTINUED ...

Page 17: ...ied AAA battery into cap and re scew to original position STEP 20 Perform Gas leakage test as shown on page 20 STEP 18 Secure deflector to heater by loosening the two screws and secure brackets underneath washers Re tighten screws to original position using screw driver INSTALLATION INSTRUCTIONS CONTINUED ...

Page 18: ... bromicheating com CONTINUED STEP 21 The back cover is secured by magnets Firstly position slots in back cover over the two hooks then lower cover to allow magnets to catch INSTALLATION INSTRUCTIONS CONTINUED ...

Page 19: ...head angle at low position remove slip pin allow heater head to rest in low posi tion Slip pin does not need to be inserted CAUTION ONLY ADJUST THE HEATER HEAD ANGLE PRIOR TO OPERATION ADJUSTING WHILST UNIT IS IN OPERATION OR POST OPERATION CAN CAUSE SERIOUS BURNS Adjusting the heater head angle High Head Tilt Position INSTALLATION INSTRUCTIONS CONTINUED ...

Page 20: ...can be applied with a spray bottle or soft cloth Turn on the gas supply at the gas cylinder Apply the soapy water solution to the 3 connections illustrated below To check connection 3 the gas control knob must be pressed in to open the gas valve If bubbles appear at any of the connections there is a gas leak If a gas leak is detected turn off the gas supply Tighten any leaking fittings and repeat ...

Page 21: ... gas to the burner The tiles should change colour from red to black 2 Turn OFF the gas supply at the LPG storage bottle 3 Turn ON the gas supply at the LPG storage bottle 4 Turn on gas control knob to maximum setting 6 When appliance is correctly turned on the tiles will start to glow red 5 Push in and hold control knob whilst simultaneously press ing the spark ignite button Continue to hold in th...

Page 22: ...e of excessive abrasion or wear or if the hose is damaged The replacement hose must be purchased from Bromic Heating Pty Ltd 2 VISUALLY CHECK BURNER FLAMES During heaters function visually check that all burners are alight and glowing hot This can be done by observing the red glow through the translucent face or by peering down the product combustion passageway Note A slight variation in colour is...

Page 23: ...ouple Burner will not stay on Loose connections Thermocouple bad Gas leak in line Lack of fuel pressure Tank near empty Tighten connections Check connections Clean dirty area Replace thermocouple Refill LPG tank Burner flame is low Supply hose is bent or twisted Straighten hose and perform leak test on hose Emitter glows uneven Low gas pressure Base is not on a level surface Replace cylinder with ...

Page 24: ...24 www bromicheating com APPENDIX A ...

Page 25: ...25 www bromicheating com APPENDIX A CONTINUED ...

Page 26: ...26 www bromicheating com APPENDIX A CONTINUED ...

Reviews: