REPLACEMENT PARTS DISCRIPTION

Note: For more information on obtaining spare parts contact the place of purchase or

BROMIC HEATING 

Head Office: 1 Suttor Street, Silverwater, Sydney, NSW 2128 Australia    

Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas)  Fax: +61 2 9748 4289   

Email: [email protected]   Web: www.bromicheating.com

No. Description

Part No. 300 Series

Part No. 500 Series

1

Front Cover

BH8080039

BH8080040

2

Flame Protector

BH8080041

BH8080042

3

Right Side Mount

BH8080043

BH8080043

4

Left Side Mount

BH8080044

BH8080044

5

Ionization Holder Assembly - including Tungsten spacer

BH8080045

BH8080045

6

White Rodger Spacer

7

Control Mount

8

Rear Housing

BH8080046

BH8080047

9

Rear Cover Assembly

BH8080048

BH8080049

10

Burner

BH8080030

BH8080030

11

Wiring H Ignitor Assembly- Honeywell

BH8080012

BH8080013

12

Inner Skin

BH8080031

BH8080032

13

Wall Bracket Assembly

BH8080001

BH8080001

14

Honeywall Control

BH8080015

BH8080015

15

Honeywell Gas Valve

BH8080014

BH8080014

16

Fenwal Control

17

White Rodger 24V Gas Valve

18

Intentionally left blank

19

Gas Inlet Fitting (Honeywell 1/2” Gas Valve)

BH8080035

BH8080035

20

Gas Outlet Fittings ( Honeywell 1/2”Gas Valve)

BH8080036

BH8080036

21

Intentionally left blank

22

Gas Outlet Fitting (WhiteRodgers Gas Valve)

23

Manifold Assembly - Natural Gas

BH8080037

BH8080038

23

Manifold Assembly - LPG

BH8080093

BH8080090

24

Injector (LPG)

BH8080016

BH8080016

24

Injector (NG)

BH8080017

BH8080017

25

Wall Bracket Replacement Screw Set including Gas Hose

BH8080051

BH8080051

26

Intentionally left blank

27

Deflector Screw Set including arm

BH8080052

BH8080052

28

Transformer – 110V-230V (Honeywall) 

BH8080050

BH8080050

Summary of Contents for SMART-HEAT TUNGSTEN 300

Page 1: ...ediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use...

Page 2: ...S MANUAL CAREFULLY before installing or servicing this product U Improper installation operation or maintenance can result in death severe injury or property damage U Installation must be carried out...

Page 3: ...ION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MA...

Page 4: ...the heater until all connections have been leak tested by an authorized person U Inspect the hose assembly before each use of the appliance U The hose assembly must be replaced prior to the appliance...

Page 5: ...pane LPG NATURAL GAS Manufactured by BROMIC HEATING PTY LTD 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 2345658 2345658 2345658 Gas Consumption 26 000 BTU 26 000 BTU 43 0...

Page 6: ...ilation U without stagnant areas U where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one...

Page 7: ...rances refer below Note When Installing with No protective cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series...

Page 8: ...U Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm U Ensure that the arm faces downwards at a 55 angle U Posi...

Page 9: ...the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting U Position heater and hose so that the...

Page 10: ...llowing the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control U Using a pair of needle nose pliers grip...

Page 11: ...with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cov...

Page 12: ...ose may be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged direc...

Page 13: ...2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower p...

Page 14: ...ny evidence of excessive wear or if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 scr...

Page 15: ...oration of the mains power supply Features U Compliance with CSA standard for automatic gas burner flame monitoring and control systems U Compliance with EN 298 European standard for automatic gas bur...

Page 16: ...alve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switch...

Page 17: ...he ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 vo...

Page 18: ...0 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OP...

Page 19: ...Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equival...

Page 20: ...V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approv...

Page 21: ...1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equiv...

Page 22: ...REPLACEMENT PARTS 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Page 23: ...080030 11 Wiring Harness Ignitor Assembly Honeywell BH8080012 BH8080013 12 Inner Skin BH8080031 BH8080032 13 Wall Bracket Assembly BH8080001 BH8080001 14 Honeywall Control BH8080015 BH8080015 15 Honey...

Page 24: ...alled on this site 300 ________ 500 ________ What type of gas is used Propane Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s...

Page 25: ...until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure...

Page 26: ...APPENDIX A...

Page 27: ...APPENDIX A CONTINUED...

Reviews: