HEAT-DEFLECTOR INSTALLATION

1.  Remove Heat Deflector and brackets from packaging

2.  Mount  Heat  Deflector  brackets  to  top  side  of  heater 

using 2 M4 screws provided

3.  Attach inner skin of heat deflector to mounting brackets 

using 4 M4 screws provided

4.  Attach Outer skin to Inner skin using 4 M4 bolts provided.

CEILING POLE INSTALLATION

1.  Mount  Top  Bracket  to  ceiling  or  support  beam  using 

suitable fixings no less than 60mm length.

2.  Assemble  pole  to  the  mounting  bracket  using  the 

M8x100mm  and  M19x100mm  bolts,  and  fix  using  nuts 
and washers (as supplied).

3.  Assemble both lower paddles to the pole (back to back) 

and  insert  3  M10x100mm  bolts  and  fix  using  nuts  and 

4.  Fix Heater to Lower paddles using suitable fixtures.

NOTE:  Tungsten  Heating  recommends  running  power  and 
gas  lines,  to  the  heater,  inside  the  pole  to  reduce  visibility 
and likelihood of damage.

INSTALLATION INSTRUCTIONS 

CONTINUED...

1

2

3

4

3

!

 

WARNING

When  mounting  ceiling  pole,  ensure  the  anchoring  to  the 

structure  is  of  sufficient  strength,  quality  and  workmanship 

to support the weight of the heater and any other load that 

could be applied to the fixture.

Summary of Contents for SMART-HEAT TUNGSTEN 300

Page 1: ...ediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use...

Page 2: ...S MANUAL CAREFULLY before installing or servicing this product U Improper installation operation or maintenance can result in death severe injury or property damage U Installation must be carried out...

Page 3: ...ION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MA...

Page 4: ...the heater until all connections have been leak tested by an authorized person U Inspect the hose assembly before each use of the appliance U The hose assembly must be replaced prior to the appliance...

Page 5: ...pane LPG NATURAL GAS Manufactured by BROMIC HEATING PTY LTD 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 2345658 2345658 2345658 Gas Consumption 26 000 BTU 26 000 BTU 43 0...

Page 6: ...ilation U without stagnant areas U where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one...

Page 7: ...rances refer below Note When Installing with No protective cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series...

Page 8: ...U Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm U Ensure that the arm faces downwards at a 55 angle U Posi...

Page 9: ...the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting U Position heater and hose so that the...

Page 10: ...llowing the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control U Using a pair of needle nose pliers grip...

Page 11: ...with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cov...

Page 12: ...ose may be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged direc...

Page 13: ...2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower p...

Page 14: ...ny evidence of excessive wear or if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 scr...

Page 15: ...oration of the mains power supply Features U Compliance with CSA standard for automatic gas burner flame monitoring and control systems U Compliance with EN 298 European standard for automatic gas bur...

Page 16: ...alve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switch...

Page 17: ...he ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 vo...

Page 18: ...0 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OP...

Page 19: ...Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equival...

Page 20: ...V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approv...

Page 21: ...1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equiv...

Page 22: ...REPLACEMENT PARTS 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Page 23: ...080030 11 Wiring Harness Ignitor Assembly Honeywell BH8080012 BH8080013 12 Inner Skin BH8080031 BH8080032 13 Wall Bracket Assembly BH8080001 BH8080001 14 Honeywall Control BH8080015 BH8080015 15 Honey...

Page 24: ...alled on this site 300 ________ 500 ________ What type of gas is used Propane Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s...

Page 25: ...until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure...

Page 26: ...APPENDIX A...

Page 27: ...APPENDIX A CONTINUED...

Reviews: