INSTALLATION INSTRUCTIONS 

CONTINUED...

GAS SUPPLY INSTALLATION

Verify  the  type  of  gas  supply  complies  with  the  appliance 
rating plate, located at the back of the heater. 

The inlet connection to the heater control box is a 1/2” NPT 
Female.

The  Control  box  has  been  fitted  at  the  factory  with  an 
approved  manual  isolating  valve  in  accordance  with 

local 

Gas Installation Codes

.

Tighten all the connections and then turn on the gas supply. 
Check  for  gas  leakage  with  a  soapy  water  solution.  (See 
section titled “Leakage Test”).

Do not use an open flame to check for leaks.

When the heater is operating, check gas pressure at the test 
point and ensure the manifold pressure to the heater is:
NG:                     

5” W.C.

PROPANE / LPG:  

10” W.C

Gas supply pressure must be limited to 14” W.C. If gas line 
pressure  exceeds  this  level,  a  separate  pressure  reducing 
regulator must be installed. 

The  appliance  and  its  individual  shutoff  valve  must  be 
disconnected from the gas supply piping system during any 
pressure testing of that system at test pressures in excess of 
1/2 psi.

The appliance must be isolated from the gas supply piping 
system by closing its individual manual shutoff valve during 
any pressure testing of the gas supply piping system at test 
pressures equal to or less than 1/2 psig.

IMPORTANT

All gas supply installation work must be performed by 
trained and authorized person(s) and comply with the 
requirements of local Gas Installation Codes.

All  Piping  Joints  should  be  tested  for  leaks  with  a 
soapy water solution before use.

Gas  hose  must  be  located  out  of  pathway  where 
people  may  trip  over  it,  or  in  areas  where  the  hose 
may be subject to accidental damage.

!

POWER SUPPLY INSTALLATION

!

WARNING 

This  heater  is  equipped  with  a  three-prong  (grounding) 
plug  for  your  protection  against  shock  hazard  and  should 
be  plugged  directly  into  a  properly  grounded  three-prong 
receptacle. Do not cut or remove the grounding prong from 
this plug.

The Tungsten Smart-Heat Heater comes standard with 36” of 
power cord in addition to the  Approved 3 pin power plug.

If an appropriate power socket is available, the heater can be 
plugged into this power socket and operated using the on/
off switch supplied on the power socket.  Alternatively, the 
power installation can be tailored to suit the site requirements 
by an Authorized Electrician.

Keep  electrical  supply  cord  away  from  any  heated  surface 
and flue gasses.

Please Note:

Tungsten Smart-Heat Heaters do not have their own on/off 
switch. Operation should be controlled via the main power 

supply.

LEAKAGE TEST

Gas connections on the heater are leak tested at the factory 
prior to shipment. A complete gas tightness check must be 
performed at the installation site due to possible mishandling 
in  shipment  or  excessive  pressure  being  applied  to  the 
heater. Check ALL connections.

The heater must be checked with the gas supply turned 
on.

Make sure the safety control valve is in the OFF position.

Make a soap solution of one part liquid detergent and 
one part water. The soap solution can be applied with a 
spray bottle, brush or rag. Soap bubbles will appear in 
case of a leak.

Turn the gas supply ON.

In  case  of  a  leak,  turn  off  the  gas  supply.  Tighten  any 
leaking fittings, then turn the gas supply on and recheck. 

Never leak test while smoking.

The  following  points  MUST  be  leak  checked  before 
operation.

WARNING

Ensure that power socket is switched off before plugging 
in power cord. 

!

1

2

Summary of Contents for SMART-HEAT TUNGSTEN 300

Page 1: ...ediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use...

Page 2: ...S MANUAL CAREFULLY before installing or servicing this product U Improper installation operation or maintenance can result in death severe injury or property damage U Installation must be carried out...

Page 3: ...ION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MA...

Page 4: ...the heater until all connections have been leak tested by an authorized person U Inspect the hose assembly before each use of the appliance U The hose assembly must be replaced prior to the appliance...

Page 5: ...pane LPG NATURAL GAS Manufactured by BROMIC HEATING PTY LTD 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 2345658 2345658 2345658 Gas Consumption 26 000 BTU 26 000 BTU 43 0...

Page 6: ...ilation U without stagnant areas U where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one...

Page 7: ...rances refer below Note When Installing with No protective cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series...

Page 8: ...U Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm U Ensure that the arm faces downwards at a 55 angle U Posi...

Page 9: ...the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting U Position heater and hose so that the...

Page 10: ...llowing the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control U Using a pair of needle nose pliers grip...

Page 11: ...with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cov...

Page 12: ...ose may be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged direc...

Page 13: ...2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower p...

Page 14: ...ny evidence of excessive wear or if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 scr...

Page 15: ...oration of the mains power supply Features U Compliance with CSA standard for automatic gas burner flame monitoring and control systems U Compliance with EN 298 European standard for automatic gas bur...

Page 16: ...alve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switch...

Page 17: ...he ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 vo...

Page 18: ...0 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OP...

Page 19: ...Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equival...

Page 20: ...V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approv...

Page 21: ...1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equiv...

Page 22: ...REPLACEMENT PARTS 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Page 23: ...080030 11 Wiring Harness Ignitor Assembly Honeywell BH8080012 BH8080013 12 Inner Skin BH8080031 BH8080032 13 Wall Bracket Assembly BH8080001 BH8080001 14 Honeywall Control BH8080015 BH8080015 15 Honey...

Page 24: ...alled on this site 300 ________ 500 ________ What type of gas is used Propane Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s...

Page 25: ...until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure...

Page 26: ...APPENDIX A...

Page 27: ...APPENDIX A CONTINUED...

Reviews: