background image

IMPORTANT NOTES AND WARNINGS

WARNING

THIS APPLIANCE SHALL NOT BE INSTALLED OR USED 
IN RESIDENTIAL DOMESTIC INDOOR AREAS

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE 
HAZARDS  OF  HIGH  SURFACE  TEMPERATURES  AND 
SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING 
IGNITION

YOUNG 

CHILDREN 

SHOULD 

BE 

CAREFULLY 

SUPERVISED  WHEN  THEY  ARE  IN  THE  AREA  OF  THE 
HEATER

DO  NOT  USE  OR  STORE  FLAMMABLE  MATERIALS 
NEAR THIS APPLIANCE

CLOTHING OR FLAMMABLE MATERIALS SHOULD NOT 
BE  HUNG  FROM  THE  HEATER  OR  PLACED  ON  OR 
NEAR THE HEATER

DO NOT SPRAY AEROSOLS OR FLAMMABLE MATERIALS 
IN THE VACINITY OF THIS APPLIANCE WHILE IT IS IN 
OPERATION

ANY  GUARD  OR  OTHER  PROTECTIVE  DEVICE 
REMOVED FOR SERVICING THE HEATER (conducted by 
an  authorized  person)  MUST  BE  REPLACED  PRIOR  TO 
OPERATING THE HEATER

INSTALLATION  AND  REPAIR  SHOULD  BE  DONE  BY  A 
QUALIFIED  SERVICE  PERSON.  THE  HEATER  SHOULD 
BE INSPECTED BEFORE USE AND AT LEAST ANNUALLY 
BY A QUALIFIED SERVICE PERSON

Failure to follow the warnings and instructions in this manual 
could  result  in  severe  personal  injury,  death  or  property 
damage.

This  Installation,  Operation  and  Maintenance  manual 
should not be removed from the site of installation.

Installer should leave manual with the customer for future 
reference.

This  Appliance  is  for  outdoor  areas  only.  (see  attached 
diagrammatical  representations  of  outdoor  areas 
“Appendix A”).

Do  not  perform  maintenance  until  heater  has  been 
turned off, power disconnected, and heater temperature 
has cooled to room temperature.

Do  not  expose  the  burner  to  water  or  moisture. 

THE 

APPLIANCE IS TO BE PROTECTED FROM RAIN.

Do not use the heater if any of these parts are exposed 
to water until the appliance is inspected or repaired by 
an authorized service person.

The installer is to ensure that the requirements of the local 
authority, local gas fitting regulations, municipal building 
codes,  and  any  other  relevant  statutory  regulations  are 
carried out.

Certain materials or items, when stored under or near the 
appliance,  will  be  subjected  to  radiant  heat  and  could 
be seriously damaged. Ensure combustible materials eg. 
overhead structures, walls, floors, furniture, fixtures and 
plants are kept at least 3ft from the top and side.

The whole gas system, hose assembly, regulator, pipes, 
and  burner  should  be  inspected  for  damage  and  leaks 
before use and at least annually by an authorized person 
for the life of the heater.

All leak tests should be done with a soap solution. Never 

Do  not  use  the  heater  until  all  connections  have  been 
leak tested by an authorized person.

Inspect  the  hose  assembly  before  each  use  of  the 
appliance.

The  hose  assembly  must  be  replaced  prior  to  the 
appliance being put into operation if there is evidence of 
excessive abrasion or wear, or if the hose is damaged.

The  replacement  hose  assembly  must  be  CSA 
approved.

The  hose  assembly  is  not  to  be  located  in  areas  where 
the hose may be subject to accidental damage

This  radiant  heater  is  NOT  intended  to  be  installed  on 
recreational vehicles and/or boats.

Repair to be carried out ONLY by an authorized person.

Improper installation, adjustment, or alteration can cause 
personal injury, property damage, or even death.

Do not attempt to alter the unit in any manner.

Remove transit protection before use.

Never  operate  the  heater  in  an  explosive  environment 
such as areas where gasorline or other flammable liquids 
or vapours are stored.

Turn  off  the  gas  supply  immediately  if  smell  of  gas  is 
detected.

Do not paint any surface of the heater.

Do not throw objects at the heater.

Control  compartment,  burner  and  circulation  air 
passageways of the heater must be kept clean. Frequent 
cleaning may be required as necessary.

Turn Gas Supply off when not in use.

Check  the  heater  immediately  if  any  of  the  following 
occurs:

 

»

The heater does not reach temperature.

 

»

The  burner  makes  popping  noise  during  use  (a 
slight noise is normal when the burner is ignited or 
extinguished).

Young children should be supervised to ensure that they 
don’t play with the appliance.

This appliance is not intended for use by young or infirm 
persons  unless  they  have  been  adequately  supervised 
by a responsible person to ensure that they can use the 
appliance safely.

Check for damage to the appliance regularly. If damage 
to the cord, plug or appliance is suspected, discontinue 
use  immediately  and  contact  the  supplier  or  qualified 
person for repair.

If the cord, plug or appliance is damaged, unplug from 
the  outlet,  discontinue  use  immediately,  and  only  an 
authorized person or similar may repair the unit.

Avoid  inhaling  fumes  emitted  from  the  heater’s  first 
use. Smoke and odour from the burning of oils used in 
manufacturing  will  appear.  Both  the  smoke  and  odour 
will dissipate after approximately 30 minutes.

Ensure  that  a  watertight  seal  is  maintained  on  the 
electrical control box at all times

Regularly  check  for  damage  to  the  rubber  seals.  If 
damage  to  the  rubber  seals  is  suspected,  discontinue 
use immediately, switch off power and contact the place 
of purchase or authorized service technician for repair.

!

Summary of Contents for SMART-HEAT TUNGSTEN 300

Page 1: ...ediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use...

Page 2: ...S MANUAL CAREFULLY before installing or servicing this product U Improper installation operation or maintenance can result in death severe injury or property damage U Installation must be carried out...

Page 3: ...ION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MA...

Page 4: ...the heater until all connections have been leak tested by an authorized person U Inspect the hose assembly before each use of the appliance U The hose assembly must be replaced prior to the appliance...

Page 5: ...pane LPG NATURAL GAS Manufactured by BROMIC HEATING PTY LTD 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 2345658 2345658 2345658 Gas Consumption 26 000 BTU 26 000 BTU 43 0...

Page 6: ...ilation U without stagnant areas U where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one...

Page 7: ...rances refer below Note When Installing with No protective cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series...

Page 8: ...U Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm U Ensure that the arm faces downwards at a 55 angle U Posi...

Page 9: ...the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting U Position heater and hose so that the...

Page 10: ...llowing the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control U Using a pair of needle nose pliers grip...

Page 11: ...with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cov...

Page 12: ...ose may be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged direc...

Page 13: ...2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower p...

Page 14: ...ny evidence of excessive wear or if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 scr...

Page 15: ...oration of the mains power supply Features U Compliance with CSA standard for automatic gas burner flame monitoring and control systems U Compliance with EN 298 European standard for automatic gas bur...

Page 16: ...alve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switch...

Page 17: ...he ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 vo...

Page 18: ...0 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OP...

Page 19: ...Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equival...

Page 20: ...V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approv...

Page 21: ...1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90 C type UL approved wire or its equiv...

Page 22: ...REPLACEMENT PARTS 1 2 3 4 5 9 10 11 24 8 12 23 6 22 7 17 13 16 19 20 15 13 14 19 White Rodger Honeywell...

Page 23: ...080030 11 Wiring Harness Ignitor Assembly Honeywell BH8080012 BH8080013 12 Inner Skin BH8080031 BH8080032 13 Wall Bracket Assembly BH8080001 BH8080001 14 Honeywall Control BH8080015 BH8080015 15 Honey...

Page 24: ...alled on this site 300 ________ 500 ________ What type of gas is used Propane Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s...

Page 25: ...until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure...

Page 26: ...APPENDIX A...

Page 27: ...APPENDIX A CONTINUED...

Reviews: