FOR INSTALLATION AND USE IN OUTDOOR OR AMPLY VENTILATED AREAS
PRODUCT FEATURES
• An amply ventilated area must have a minimum of
25% of the surface area open.
• The surface area is the sum of the walls surface An
amply ventilated area must have a minimum of 25% of
the surface area open. The surface area is the sum of
the walls surface.
IMPORTANT
This appliance shall only be used in above ground
open-air situations with:
• natural ventilation
• without stagnant areas
• where gas leakage and products of combustion
are rapidly dispersed by wind and natural
convection
Any enclosure in which the appliance is used shall
comply with one of the following:
1. 25% of surface area is open. The surface area is the
sum of the wall surface (ref. Appendix A, Example 1)
2. Within a partial enclosure that includes an overhead
cover and no more than two walls (ref. Appendix A,
Example 2)
3. Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall
apply:
• At least 25% of the total wall area is
completely open (ref. Appendix A, Example 4), and
• At least 30% of the remaining wall area is open
and unrestricted (ref. Appendix A, Example 4)
Note: The definition of outdoors is an above ground
openair situation with natural ventilation, without
stagnant areas, where gas leakage and products of
combustion are rapidly dispersed by wind and natural
convection.
!
GAS REQUIREMENTS
Platinum Smart-Heat LPG Models:
• Use Propane (LPG) gas only
• The approved inlet pressure to the appliance
Platinum Smart-Heat Natural Gas Models:
• Use Natural Gas Only
• The approved inlet pressure to the appliance
“The tubing or the flexible hose must be changed within
the prescribed intervals”;
“Use only the type of gas and the type of cylinder
specified by the manufacturer”;
This appliance must be installed and the
gas cylinder stored in accordance with the
regulations in force.