background image

15

bromic.com/heat

INSTALLATION INSTRUCTIONS 

CONTINUED...

1

2

3

4

CEILING POLE INSTALLATION

!

WARNING 

When mounting ceiling pole, ensure the anchoring 

to the structure is of sufficient strength, quality and 

workmanship to support the weight of the heater and 

any other load that could be applied to the fixture. 

Note: Ceiling pole must be perpendicular (90deg) to 

the ground when mounted  (irrespective of pitched 

or flat ceiling).

1.  Mount Top Bracket to ceiling or support beam 

using suitable fixings no less than 60mm length.
2.  Assemble pole to the mounting bracket 

using the M8x100mm and M19x100mm bolts, and 

fix using  

 

 

nuts and washers (as 

supplied).
3.  Assemble both lower paddles to the pole (back 

to back) and insert 3 M10x100mm bolts and fix 

using nuts and washers (as supplied).
4.  Fix Heater to Lower paddles using suitable 

fixtures.

NOTE: Platinum Smart-Heat Heating 

recommends running power and gas lines, to 

the heater, inside the pole to reduce visibility 

and likelihood of damage.

Burner pressure test point

Summary of Contents for PLATINUM 300 SMART-HEAT

Page 1: ...ues keep away from the appliance and immediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other applian...

Page 2: ...lled must be electrically grounded in accordance with local codes This appliance is approved FOR OUTDOOR OR AMPLY VENTILATED AREA USE and for NON DOMESTIC INDOOR APPLICATION When installed outdoors th...

Page 3: ...WER SUPPLY INSTALLATION 13 LEAKAGE TEST 13 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 14 COMMISSIONING INSTRUCTION CHECK GAS PRESSURE 14 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 15 OPERATING INSTRUC...

Page 4: ...roved The hose assembly is not to be located in areas where the hose may be subject to accidental damage This radiant heater is NOT intended to be installed on recreational vehicles and or boats Repai...

Page 5: ...ce shall be used on a regulated supply 3 Governor out of action 4 Not designed for field conversion SPECIFICATIONS Table 1 Platinum Smart Heat 500 Gas type G31 PROPANE1 G20 NATURAL GAS2 G25 NATURAL GA...

Page 6: ...omestic indoor use In addition to the installation instructions provided authorised installers must abide by the local gas installation code Please note that these standards are subject to change The...

Page 7: ...re than two walls ref Appendix A Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following shall apply At least 25 of the total wall area is complete...

Page 8: ...300 Series 1100mm 1100mm 2500mm 500 Series 1100mm 1100mm 2500mm following installation clearances shall apply Note When installing with the Platinum Smart Heat C Minimum Mounting Height to Ground B A...

Page 9: ...inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm Ensure that the arm faces downwards at a 55 angle Position the 4 mounting holes on the arms plate...

Page 10: ...slide into place TIP Do not install the mounting pin at this point Spray soapy water on the arm to ease the sliding 5 Connect an approved flexible connector to the Gas Valve Outlet Fitting Position he...

Page 11: ...carefully following the instructions below IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only PLEASE NOTE THERE IS NO NEED TO REMOVE OR UNPLUG THE...

Page 12: ...TANT Ensure that a water tight seal is maintained 10 Main Power supply connection is to completed in line with instructions in the Power supply installa tion section of this manual IMPORTANT Children...

Page 13: ...EAKAGE TEST Gas connections on the heater are leak tested at the factory prior to shipment A complete gas tightness check must be performed at the installation site due to possible mishandling in ship...

Page 14: ...r pressure test point sealing screw one to two turns on the Honeywell multifunctional control and connect a manometer see photography B1 Turn on the appliance and operate for at least 5 minutes Check...

Page 15: ...spective of pitched or flat ceiling 1 Mount Top Bracket to ceiling or support beam using suitable fixings no less than 60mm length 2 Assemble pole to the mounting bracket using the M8x100mm and M19x10...

Page 16: ...s gasoline and other flamable vapors and liquids Do not clean heater with cleaners that are combustible or corrosive REGULAR SERVICE REQUIREMENTS 1 AGA approved Gas Hose located within the mounting ar...

Page 17: ...le for atmospheric gas burners for non permanent operation Although the Honeywell unit is available non volatile lockout its configuration in the Platinum Smart Heat series heaters limits it to volati...

Page 18: ...me is detected during the safety time the ignition device is inhibited and the gas valve remains energised If the control does not detect any flame signal during the safety time at the end of safety t...

Page 19: ...ed 230 V Blue Purple Purple ELECTRICAL DIAGRAM SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS Note If any of the original wire as supplied with the heater must be repla...

Page 20: ...20 bromic com heat REPLACEMENT PARTS 8 13 16 7 1 2 1 4 5 6 9 11 15 27 14 26 12 25 20 17 18 24 Honeywell...

Page 21: ...ing Mount Bottom 12 Rear Cover Assembly BH8080026 BH8080027 13 Rear Cover Mount 14 Burner BH8080030 BH8080030 15 Wiring Harness Ignitor Assembly BH8080010 BH8080011 16 Inner Skin BH8080028 BH8080029 1...

Page 22: ...Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s installation location pose a hazard to the site Yes No Do heater clearances match the minimu...

Page 23: ...matter in venturi tube 1 Adjust valve regulator until 1kpa for natural gas or 2 75kpa for propane is obtained 2 Adjust main supply regulator until at least 1 25kpa for natural gas or 3kpa for propane...

Page 24: ...24 bromic com heat APPENDIX A Note For clearance from combustible materials see page 7...

Page 25: ...25 bromic com heat APPENDIX A CONTINUED...

Page 26: ...ERMANY 8 DK DENMARK 9 EE ESTONIA 10 ES SPAIN 11 FI FINLAND 12 FR FRANCE 13 GB GREAT BRITAIN 14 GR GREECE 15 HR CROATIA 16 HU HUNGARY 17 IE IRELAND 18 IS ICELAND 19 IT ITALY 20 LT LITHUANIA 21 LU LUXEM...

Reviews: