15
bromic.com/heat
INSTALLATION INSTRUCTIONS
CONTINUED...
1
2
3
4
CEILING POLE INSTALLATION
!
WARNING
When mounting ceiling pole, ensure the anchoring
to the structure is of sufficient strength, quality and
workmanship to support the weight of the heater and
any other load that could be applied to the fixture.
Note: Ceiling pole must be perpendicular (90deg) to
the ground when mounted (irrespective of pitched
or flat ceiling).
1. Mount Top Bracket to ceiling or support beam
using suitable fixings no less than 60mm length.
2. Assemble pole to the mounting bracket
using the M8x100mm and M19x100mm bolts, and
fix using
nuts and washers (as
supplied).
3. Assemble both lower paddles to the pole (back
to back) and insert 3 M10x100mm bolts and fix
using nuts and washers (as supplied).
4. Fix Heater to Lower paddles using suitable
fixtures.
NOTE: Platinum Smart-Heat Heating
recommends running power and gas lines, to
the heater, inside the pole to reduce visibility
and likelihood of damage.
Burner pressure test point