6
www.bromicheating.com
pRODUCT OvERvIEW
CONTINUED...
General InFormatIon
The Tungsten Series Gas radiant heaters are suitable for outdoor spaces. In addition to the installation instructions provided,
authorized installers must abide by
local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54, Natural Gas and Propane Installation Code, CSA B149.1, or Propane Storage and Handling Code,
B149.2
. Please note that these standards are subject to change.
The heater is designed to function in winds up to 10mph. The heater is subject to reduced performance or failure in adverse
weather conditions such as high wind or extreme saturation.
Product Features
Tungsten Smart-Heat gas radiant heaters are revolutionizing the outdoor heating industry by introducing groundbreaking
benefits never seen before in traditional gas or electric heaters. Tungsten Smart-Heat heaters have set the industry benchmark
with stylish good looks and world-first innovation.
Tungsten Smart-Heat heaters excel in the areas of:
•
Aesthetic appeal
•
Innovation
•
Performance
•
Flexibility
•
Cost effectiveness
For more detailed product information, visit www.bromicheating.com
INSTALLATION REQUIREMENTS
ImPortant
This appliance shall only be used in above ground open-air
situations with:
•
natural ventilation
•
without stagnant areas
•
where gas leakage and products of combustion are
rapidly dispersed by wind and natural convection
Any enclosure in which the appliance is used shall comply
with one of the following:
1. An enclosure with walls on all sides, but at least one
permanent opening at ground level (ref. Appendix A,
Example 1)
2. Within a partial enclosure that includes an overhead
cover and no more than two walls (ref. Appendix A,
Example 2)
3. Within a partial enclosure that includes an overhead
cover and more than two walls, the following shall apply:
•
At least 25% of the total wall area is completely open
(ref. Appendix A, Example 4), and
•
At least 30% of the remaining wall area is open and
unrestricted (ref. Appendix A, Example 4)
Note: The definition of outdoors is an above ground open-
air situation with natural ventilation, without stagnant areas,
where gas leakage and products of combustion are rapidly
dispersed by wind and natural convection.
!
Gas reQuIrements
Tungsten LpG Models:
•
Use Propane (LPG) gas only
•
The approved manifold pressure to the appliance is
10”W.C.
•
The MIN inlet pressure to the appliance is 11” W.C
•
The MAX inlet pressure to the appliance is 14” W.C
Tungsten Natural Gas Models:
•
Use Natural Gas Only
•
Always use Natural Gas Regulator (supplied internal to
the gas valve)
•
Ensure that Inlet pressure to the regulator does not
exceed 14” W.C.
•
The MIN inlet pressure to the appliance is 6” W.C
•
The approved manifold pressure to the appliance is
5”W.C.