Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

EARTH 

WIRE

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

EARTH 

WIRE

Heater Element 2

WIRING DIAGRAM

COBALT  SMART-HEAT ELECTRIC

OPTIONAL INSTALLATION

4000W & 6000W MODELS

Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

AC

240 V AC

SINGLE PHASE

EARTH 

WIRE

Heater Element 2

WIRING DIAGRAM

COBALT  SMART-HEAT ELECTRIC

STANDARD INSTALLATION

4000W & 6000W MODELS

WIRING DIAGRAM

COBALT SMART-HEAT ELECTRIC

STANDARD INSTALLATION

2000W & 3000W MODELS

www.bromicheating.com

ELECTRIC AL INSTALLATION 

CONTINUED...

For longest product life & to maintain product appearance 
mount heater under cover & protect from rain & weather 
whenever possible.
The exterior housing of the heater should be cleaned 
regularly with a soft damp cloth. For locations near the 
coast, salt in the air can cause rusting of metal. Additional 
cleaning of the heater with a soft damp cloth fortnightly will 
increase the life of the products appearance.
Ensure that there is no excessive build-up of dirt/dust on 
the reflectors or elements as this can cause overheating 
and premature element failure. To clean the reflectors and 
elements, ensure heater is off and has been off for at least 2 
hours after operation, and wipe off any dirt/dust with a soft 
& dry cloth

.

MAINTENANCE 

SERVICING

TUBE ELEMENT REPLACEMENT

WARNING

ELECTRICAL SHOCK HAZARD!

Serious injury or death may occur.

Disconnect from electrical supply before servicing this 

heater.

!

!

WARNING

Servicing and maintenance MUST be carried out by an 

authorised and licensed person only

1. Remove the wire cover by pulling it out from under the

edge of the heater and in between reflector.

2. Remove first Element End Cover by unscrewing the 2

screws holding it in place.

3. Remove Outer Hex Nut, Lock Washer and Lead Wire

Ring Terminal from the threaded stud.

4. Remove second Element End Cover by unscrewing the

2 screws holding it in place.

5. Remove Outer Hex Nut, Lock Washer and Lead Wire

Ring Terminal from the threaded stud.

6. Remove old Tube Element.
7. Install new Tube Element by following element installa-

tion instructions on page 11 of this manual.

Summary of Contents for BH0610001

Page 1: ...T INFORMATION ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE COBALT SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATE...

Page 2: ...ter only as described in this manual Any other use not recommended by manufacturer may cause fire electric shock or injury to persons For Domestic and Commercial Use CONTENTS IMPORTANT NOTES WARNINGS...

Page 3: ...n accordance with Test for Permanence of Cord Tag Section 53 This Installation Operation and Service manual should not be removed from the site of installation Installer should leave manual with the c...

Page 4: ...nts are horizontal Failure to do this will cause the heating element within the tube to sag and cause premature burnout Installing vertically will void the manufacturers warranty WARNING DO NOT MOUNT...

Page 5: ...fasteners Not supplied 2 Heater must be installed with heater surface at least 7 10 above the floor level Supplied suspension tubes position heater surface 39 4 below the ceiling surface If required...

Page 6: ...ck washer Use one spanner to hold the inner nut on the element while fastening the outer nut with a second spanner Repeat for other end of element 4 Put elements in the support bracket For 2000W 3000W...

Page 7: ...ith local electrical code regulations For outdoor installation all connections must be made in accordance with local electrical code regulations for outdoor wiring Only use wiring components approved...

Page 8: ...a soft damp cloth For locations near the coast salt in the air can cause rusting of metal Additional cleaning of the heater with a soft damp cloth fortnightly will increase the life of the products a...

Page 9: ...Long Cobalt electric BH8180036 12 Ceiling recess kit Cobalt electric 2000W 4000W BH3130014 13 Ceiling recess kit Cobalt electric 3000W 6000W BH3130015 14 Tube suspension kit Cobalt electric BH3130016...

Reviews: