Pulse Input Time Unit (
Time UNIT
)
This is the time component for the engineering units of the display values being entered. Enter the
appropriate units/second, units/minute, units/hour, or units/day that corresponds to the values being
entered at the
display 1-32
(
dsp
) menus.
For example, if the display values are being entered in gallons/second the time unit would be set to
seconds.
Manual Multi-point Entry (
INP
,
DSP
)
Manual entry of the linearization data is done once the number of points has been selected (
NO PTS
).
Input signal levels (
InP 1-32
) for up to 32 points, along with the desired/corresponding meter reading
(
dSP 1-32
), should be entered fo
r
each linearization point.
Each scale point (1-32) has an input value and a display value. The input value is the number of
pulses/sec (frequency), and the display value is the corresponding display value for that input in the time
unit selected (example: gallons per minute, or
GAL/M
)
Important Programming Note: Save (
save?
)
After entering the last display value, the scaling entries must be saved (
SAUE?
)
before they will be put into effect.
However
, you may move past this selection
using the Up arrow key if you need to go back and correct an earlier entry. Once
confident in the entries, however, the user must navigate back to the Save menu
screen (
SAUE?
) and press the
Enter
key to save the changes.
55
Summary of Contents for BERT-E
Page 1: ...Model BERT E Installa on and Opera on Manual BI BERT Revision 01 Engineered for Accuracy...
Page 28: ...26...
Page 38: ...36...
Page 51: ...49...
Page 68: ...66...
Page 70: ...68...
Page 78: ...76...
Page 84: ...Mounting Dimensions All units inches mm Figure 14 Enclosure Dimensions Front View 82...
Page 90: ...This page left blank intentionally 88...
Page 91: ...Notes 89...
Page 92: ...Notes 90...
Page 93: ......