14
Brocade VDX 8770-8 Hardware Reference Manual
53-1002564-01
Preparing for the Brocade VDX 8770-8 installation
2
The power requirements for a given chassis configuration depend on which modules have been
installed in the chassis.
Table 4
shows the power consumption for the modules that can be used in
the Brocade VDX 8770-8 chassis along with the power consumption for the cooling fans.
All numbers for the line cards assume that the card is fully populated with optical transceivers,
including QSFPs for the 12x40G line cards. All ports are Ethernet.
You can calculate your power requirements by combining the power demands for the various
modules and fan units in your configuration. While you may use fewer ports in a given line card, it is
always safer to use the power requirement of a fully populated card.
Table 5
illustrates the power consuption for a fully configured chassis at idle, nominal, and
maximum power demands.
TABLE 4
Power demands per component
Module or fan units
Power demand at
idle - blades
enabled, no optics,
ports disabled
(Watts)
Nominal power demand
- blades enabled,
optics, 50% line rate,
random packets (Watts)
Maximum power demand - blades
enabled, optics, traffic present,
full line rate, 64 byte smallest
packet, 40C ambient temp.,
maximum power for all supported
optics (Watts)
Ports per module
Number of modules
permitted in chassis
Management
module
46
46
50
NA
2
Switch fabric
module
120
120
132
NA
6
48x1G line card
245???
310???
460???
48 1 Gbps
up to 8
48x10G line card
245
310
460
48 10 Gbps
up to 8
12x40G line card
247
290
440
12 40 Gbps
up to 8
Fan unit
25
25
268
NA
4
TABLE 5
Power demands for fully configured Brocade VDX 8770-8 chassis
Module or fan units
Power demand at idle -
blades enabled, no
optics, ports disabled
(Watts)
Nominal power demand -
blades enabled, optics, 50%
line rate, random packets
(Watts)
Maximum power demand - blades
enabled, optics, traffic present, full line
rate, 64 byte smallest packet, 40C
ambient temp., maximum power for all
supported optics (Watts)
2 management
modules
92
92
100
6 switch fabric
modules
720
720
792
8 48x10G line cards
1960
2480
3680
no 12x40G line cards
0
0
0
4 fan units
100
100
1072
Total DC power
demand
2872
3392
5644
Summary of Contents for VDX 8770-8
Page 1: ...53 1002564 01 15 October 2012 Brocade VDX 8770 8 Hardware Reference Manual...
Page 3: ...Brocade VDX 8770 8 Hardware Reference Manual 3 53 1002564 01...
Page 4: ...4 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...
Page 10: ...viii Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...
Page 12: ...x Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01...
Page 26: ...8 Brocade VDX 8770 8 Hardware Reference Manual 53 1002564 01 Software features 1...