Page 3

MODELS QTRE080H • QTRE100H

BD0002

STD

1b. Mount housing anywhere between trusses, 

joists, or 

I

-joists using hanger bars.

 

Sliding  hanger  bars  are  provided  to  allow  for  accurate 
positioning of housing anywhere between framing. They can 
be used on all types of framing (

I

-joist, standard joist, and 

truss construction) and span up to 24”.

Attach  the  MOUNTING  CHANNELS  to  the  housing  using 
the SCREWS supplied. Make sure TABS face “up” as shown. 
Use the set of channel mounting holes (marked “STD”) to 
mount the housing flush with the bottom of the drywall. Use 
the  other  set  of  holes  (not  marked)  to  mount  the  housing 
flush with the top of the drywall.

HANGER

BAR (4)

SCREWS (4)

 

Extend HANGER BARS to the width of the framing.

 

Hold  ventilator  in  place  with  the  hanger  bar  tabs  wrapping 
around the BOTTOM EDGE OF THE FRAMING.

 

NAIL ventilator to framing or fasten with screws (not provided) 
through HOLES near nails.

 

*To ensure a noise-free mount: Secure hanger bars together 
with  SCREWS  or  use  a  pliers  to  crimp  mounting  channels 
tightly around hanger bars.

*SCREW (2)

HOLE FOR OPTIONAL 

SCREW MOUNTING (4)

MOUNTING

CHANNEL (2)

NAIL (4)

BOTTOM EDGE

OF FRAMING

4.  Connect electrical wiring.

 

Run 120 VAC house wiring to installation location. Use proper 
UL approved connector to secure house wiring to wiring plate. 
Connect wires as shown in wiring diagrams.

CONNECT WIRING

ON / OFF SWITCH

(PURCHASE SEPARATELY)

ON / OFF

SWITCH

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

WHT

UNIT

ORG

BLK

WHT

GRD

WHT

BLK

WHT

BRN

HUMIDITY
CONTROL

FAN

BE0011A

2.  Attach damper/

duct connector.

 

Snap damper/duct 
connector onto housing. 
Make sure connector is 
flush with top of housing 
and damper flap falls 
closed.

3.  Install

4-inch round
ductwork.

 

Connect 4-inch round 
ductwork to damper/duct 
connector. Run ductwork 
to a roof cap or wall 
cap. Tape all ductwork 
connections to make them 
secure and air tight.

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

WHT

UNIT

BLK

WHT

GRD

WHT

BLK

WHT

HUMIDITY
CONTROL

FAN

RED

BLK

ORG

BRN

MODEL 68W, 2-FUNCTION CONTROL

(PURCHASE SEPARATELY)

COM

HUMIDITY
CONTROL

(AUTO/OFF)

FAN

(ON/OFF)

WIRING OPTION No. 1 - Allows fan to operate in automatic mode or manual 
mode (for odor control) by cycling ON/OFF switch.

WIRING OPTION No. 2 - Fan can be turned ON, OFF, or set to operate automatically.

TAB