MODELS QTRE080H • QTRE100H

TYPICAL INSTALLATIONS

BH0001A

Housing mounted to

I

-joists.

A

Housing mounted anywhere 

between trusses 

using hanger bars.

A

PLAN THE INSTALLATION

1.  Choose the 

installation 
location.

The location of your 
humidity sensing fan 
is very important. 
Use the following 
guidelines for best 
operation:

2A

Housing mounted

anywhere between

I

-joists using hanger bars.

Housing mounted to joists.

Housing mounted

anywhere between

joists using hanger bars.

Housing mounted anywhere 

between trusses 

using hanger bars.

BH0006A

INSTALL HOUSING & DUCT

1a. Mount 

housing 
to joist 
or 

I

-joist.

 

Use pliers to 
bend housing 

TABS

 out to 90°. 

Hold housing 
in place so that 
the housing 
tabs contact the 
bottom of the 
joist. The housing 
mounts with four 
screws or nails. 
Screw or nail 
housing to joist 
through lowest 
holes in each 
mounting flange, 
then through 
highest holes.

 

NOTE: Mounting 
to 

I

-JOIST

 

(shown) requires use of 

SPACERS

 (included) between 

the highest hole of each mounting flange and the 

I

-joist.

OR

ROOF
CAP

*

4-IN. ROUND

ELBOW(S) 

*

4-IN.

ROUND

DUCT

*

WALL

CAP

*

*

Purchase

 

separately

INSULATION

(Can be placed 

around and over

fan housing.)

FAN

HOUSING

•  Locate unit above (GFCI protected circuit required) or 

within 5 feet of shower head.

•  Locate unit away from heating or cooling sources which 

can affect humidity levels.

•  Do  not  locate  near  window.  Unit  may  respond  to  the 

outdoor humidity level.

•  Unit  must  be  installed  in  ceiling  to  properly  sense 

moisture.

•  Locate unit only on flat ceilings up to 12 feet high for 

proper sensing.

•  The fan will operate most efficiently when located where 

the shortest possible duct run and minimum number of 
elbows will be needed.

•  Use a roof cap or wall cap that has a built-in damper to 

reduce backdrafts.

2.  Plan the wiring.

•  Plan  to  supply  the  unit  with  proper  line  voltage  and 

appropriate  power  cable.  Power  cable  should  be 
routed to the switch box first and then to the unit (See 
“CONNECT WIRING” on page 3).

•  Do not operate this unit with a speed control. 

Damage to the sensor unit will result.