12 

DUCTED INSTALLATION ONLY:

Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch 

round 

knockout plate(s)

 as appropriate for your ducting 

method.

13 

DUCTED INSTALLATION ONLY:

Attach 

3¼” x 10” Damper/Duct Connector

 (if using 3¼” 

x 10” duct) or 

7” Round Duct Plate

 (if using 7-inch round 

duct) over the knockout opening.

3¼” X 10”

HORIZONTAL

KNOCKOUT

PLATE

3¼” X 10”

VERTICAL

KNOCKOUT

PLATE

7” ROUND

KNOCKOUT

PLATE (also 

remove 3¼” x 10” 

vertical plate)

7” ROUND 

DUCT 

PLATE

Notes:

To accomodate off-center ductwork, the 3¼” x 10” 

damper/duct connector can be installed up to ½” on either 

side of the hood center and the 7” round duct plate can 

be installed up to ½” on either side of the hood center.
Install the 3¼” x 10” Damper/Duct Connector with the 

Damper Flap Pivot

 nearest the 

Top/Back Edge of 

Hood

.

INSTALL THE HOOD

15 

Run 

House Power Cable

 between service panel and hood 

location. Attach power cable to hood using appropriate clamp.

16 

Hang hood from (4) mounting screws driven part-way into 

cabinet locations (shown in illustrations under “PREPARE 

HOOD LOCATION”). Mounting screws are included in parts 

bag. Slide hood back towards wall until mounting screw 

heads are engaged in narrow end of keyhole slots in top of 

hood. Tighten screws securely. Add 5th mounting screw in 

center hole in hood and tighten securely.

17 

DUCTED INSTALLATION ONLY:

Connect ductwork to hood and use duct tape to make joints 

secure and air-tight.

 

Make sure the damper / duct connector 

enters the ductwork and that the damper opens and closes 

freely.

HOUSE

POWER CABLE

WARNING

 

 

To reduce the risk of electrical shock, switch power off  

 

 

at service panel. Lock or tag service panel to prevent    

 

 

power from being switched on accidentally.

ELECTRICAL 

WIRING BOX 

COVER

14 

Remove 

Electrical Wiring Box Cover

 from inside 

of hood and appropriate 

Electrical Power Cable 

Knockout

 from top or back of hood.

ELECTRICAL 

POWER

CABLE

KNOCKOUT

TOP/BACK

EDGE OF

HOOD

3¼” X 10”

DAMPER / 

DUCT 

CONNECTOR

DAMPER

FLAP

PIVOT

Summary of Contents for EVOLUTION 1 QP142BL

Page 1: ...n ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK...

Page 2: ...ntally 3 x 10 only For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitions and elbows OPERATION Alwa...

Page 3: ...lding Bottom Pan to hood Set bot tom pan and screws aside 1 PULL DOWN 2 LIFT OUT Note the extra wood shim and mounting screw near the cabinet front on the cabinet center line BOTTOM PAN 3 X 10 HORIZON...

Page 4: ...D INSTALLATIONS Skip to INSTALL THE HOOD 9 NON DUCTED INSTALLATION ONLY Remove 2 Screws holding Non Duct Plate to Non Duct Plenum and remove plate 10 NON DUCTED INSTALLATION ONLY Insert short end of N...

Page 5: ...ion Attach power cable to hood using appropriate clamp 16 Hang hood from 4 mounting screws driven part way into cabinet locations shown in illustrations under PREPARE HOOD LOCATION Mounting screws are...

Page 6: ...y Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express...

Page 7: ...ors mounting hardware 9 97017728 Damper Duct Connector includes mounting hardware 10 97018229 Light Panel LH White includes mounting hardware 97018230 Light Panel LH Black includes mounting hardware 9...

Page 8: ...lamb 3 Nettoyez souvent la hotte Ne laissez pas la graisse s accumuler sur le ventilateur ou les filtres 4 Utilisez des casseroles de dimension appropri e Utilisez toujours une batterie de cuisine ada...

Page 9: ...ent Pour une vacuation verticale ou horizontale installez les conduits entre un capuchon de toit ou un capuchon mural Pour obtenir les meilleurs r sultats utilisez un minimum de coudes et de transitio...

Page 10: ...vis de c t 1 TIRER VERS LE BAS 2 SOULEVER Remarquez la cale de bois et la vis suppl mentaires pr s de l avant de l armoire sur la ligne centrale de l armoire PANNEAU INF RIEUR CONDUIT HORIZONTAL 8 3...

Page 11: ...DE LA HOTTE 9 INSTALLATION SANS CONDUIT SEULEMENT Enlevez les 2 vis retenant la plaque non canalis e au caisson non canalis et retirez la plaque 10 INSTALLATION SANS CONDUIT SEULEMENT Ins rez la peti...

Page 12: ...i re de la hotte INSTALLATION DE LA HOTTE 15 Acheminez le fil d alimentation lectrique du panneau lectrique jusqu l emplacement de la hotte Fixez le c ble la hotte avec le connecteur appropri 16 Suspe...

Page 13: ...vaise installation ou une installation contraire aux instructions recommand es La dur e de toute garantie tacite est limit e cette p riode d un an tel que stipul pour la garantie expresse Certains ter...

Page 14: ...quincaillerie de montage 9 97017728 Clapet raccord de conduit incluant la quincaillerie de montage 10 97018229 Panneau d clairage blanc GAUCHE comprend la quincaillerie de montage 97018230 Panneau d...

Page 15: ...s Suzette cerezas Jubilee bistec con pimienta flameado 3 Limpie frecuentemente los ventiladores No permita la acumulaci n de grasa en el ventilador ni en el filtro 4 Use una cacerola del tama o adecua...

Page 16: ...s lo conducto de 3 x 10 pulg 8 3 x 25 4 cm Para descarga vertical u horizontal coloque la red de conductos entre el lugar donde va a instalar la campana y el tap n de techo o tap n de pared Para obte...

Page 17: ...piente inferior y los tornillos 1 JALAR HACIA ABAJO 2 LEVANTAR HACIA FUERA Observe la cu a de madera adicional y el tornillo de montaje cerca del frente del gabinete sobre la l nea central del gabinet...

Page 18: ...ES SIN CONDUCTOS Quite 2 tornillos que sostienen la placa sin conducto al pleno sin conducto y quite la placa 10 NICAMENTE EN INSTALACIONES SIN CONDUCTOS Inserte el extremo corto de la placa sin condu...

Page 19: ...servicio y la campana Conecte el cable el ctrico a la campana con la abrazadera apropiada 16 Cuelgue la campana de los 4 orificios de montaje insertados parcialmente en las posiciones del gabinete mo...

Page 20: ...de las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita al per odo de un a o como se especifica para la garant a expresa Algunos estados no permiten limi...

Page 21: ...de montaje 9 97017728 Conector del regulador de tiro conducto incluye las piezas de montaje 10 97018229 Panel de luces IZQUIERDO color blanco incluye piezas de montaje 97018230 Panel de luces IZQUIERD...

Reviews: