Broan EVOLUTION 1 QP142BL Instructions Manual Download Page 17

Página 17

MODELOS  QP142SS • QP142WW • QP142BL

2 1/8” 

(5.4 cm)

6 7/8” 

(17.5 cm)

10 7/8” 

(27.6 cm)

2 5/8” 

(6.7 cm)

TORNILLOS DE MONTAJE 

DE LA CAMPANA (5)

4 5/8” (11.7 cm)

AGUJ. de 

8" pulg. 

(20.3 cm) 

DE DIÁM.

ORIFICIO DE 

ACCESO PARA 

CONDUCTO 

REDONDO 

DE 7 pulg. 

(17.8 cm)

ORIFICIO DE 

ACCESO PARA 

CONDUCTO 

REDONDO 

DE 7 pulg. 

(17.8 cm)

11” (27.9 cm)

*

17 5/8 pulg. 

(44.8 cm) 

17 5/8 pulg. 

(44.8 cm) 

FRENTE DEL 

GABINETE

PARTE 

INFERIOR 

DEL 

GABINETE

CUÑAS DE 

MADERA 

(sólo gabinetes de 

fondo empotrado)

LÍNEA 

CENTRAL

ORIFICIO DE 

ACCESO PARA 

CABLES ELÉCTRICOS 

(en el fondo del gabinete)

PREPARE LA CAMPANA

Quite los 2 tornillos que sujetan el conector del regulador de 

tiro/conducto a la campana. Quite el 

conector del regulador 

de tiro/conducto

 del interior de la campana.

   PARA INSTALACIONES CON CONDUCTOS: pase directamente al 

paso 12.

CONECTOR DEL 

REGULADOR DE 

TIRO/CONDUCTO

FILTROS DE  

ALUMINIO

Quite los 

filtros de aluminio

 de la campana.

ç

Quite todo el forro de plástico protector de la campana 

(únicamente campanas de acero inoxidable).

Quite la bolsa de piezas del interior del cuadro de hardware 

incluido con la campana.

Quite los 6 tornillos que sostienen el 

recipiente inferior

 a la 

campana. Deje a un lado el recipiente inferior y los tornillos.

(1) 

JALAR 

HACIA 

ABAJO

(2) 

LEVANTAR 

HACIA 

FUERA

ç

*  Observe la cuña de madera adicional y el tornillo de montaje cerca 

del frente del gabinete, sobre la línea central del gabinete.

RECIPIENTE 

INFERIOR

CONDUCTO HORIZONTAL DE 

3¼ X 10 PULG. (8.3 X 25.4 CM)

PARTE 

INFERIOR 

DEL GABINETE

FRENTE DEL 

GABINETE

ORIFICIO DE ACCESO PARA 

CONDUCTO HORIZONTAL

5¼” 

(13.3 cm) 

TORNILLOS 

DE MONTAJE 

DE LA 

CAMPANA (5)

ORIFICIO 

DE ACCESO 

PARA CABLES 

ELÉCTRICOS 

(en la pared)

4” (10.2 cm)

LÍNEA 

CENTRAL

CUÑAS DE MADERA 

(sólo gabinetes de 

fondo empotrado)

6 7/8” 

(17.5 cm)

1 3/8” (3.5 cm)

3/8” (1 cm)

*

5¼” 

(13.3 cm) 

17 5/8 pulg. (44.8 cm) 

17 5/8 pulg. (44.8 cm) 

CONDUCTO REDONDO 

DE 7 PULG. (17.8 CM)

¾”

 

(1.9 cm)

LÍNEA 

CENTRAL

TORNILLOS DE MONTAJE 

DE LA CAMPANA (5)

ORIFICIO DE 

ACCESO 

PARA CABLES 

ELÉCTRICOS 

(en el fondo del gabinete)

CUÑAS DE 

MADERA 

(sólo gabinetes de 

fondo empotrado)

FRENTE DEL 

GABINETE

PARTE  INFERIOR 

DEL  GABINETE

4½” 

(11.4 cm)

2 1/8” 

(5.4 cm)

17 5/8 pulg. 

(44.8 cm) 

2 5/8” 

(6.7 cm)

11” 

(27.9 cm)

*

ORIFICIO DE ACCESO PARA 

CONDUCTO VERTICAL

17 5/8 pulg. 

(44.8 cm) 

5¼”

(13.3 cm)

5¼” 

(13.3 cm)

10 7/8” 

(27.6 cm)

6 7/8” 

(17.5 cm)

CONDUCTO VERTICAL DE  

3¼ X 10 PULG. (8.3 X 25.4 CM)

Guíese por el diagrama correspondiente (a continuación) para 

colocar los conductos y hacer el corte exacto para la conexión 

eléctrica en el gabinete o en la pared. Para instalaciones en 

sistemas sin conductos, NO haga ningún orificio de acceso  

para conducto.

Summary of Contents for EVOLUTION 1 QP142BL

Page 1: ...n ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surface element TO REDUCE THE RISK...

Page 2: ...ntally 3 x 10 only For vertical or horizontal discharge run ductwork between the hood location and a roof cap or wall cap For best results use a minimum number of transitions and elbows OPERATION Alwa...

Page 3: ...lding Bottom Pan to hood Set bot tom pan and screws aside 1 PULL DOWN 2 LIFT OUT Note the extra wood shim and mounting screw near the cabinet front on the cabinet center line BOTTOM PAN 3 X 10 HORIZON...

Page 4: ...D INSTALLATIONS Skip to INSTALL THE HOOD 9 NON DUCTED INSTALLATION ONLY Remove 2 Screws holding Non Duct Plate to Non Duct Plenum and remove plate 10 NON DUCTED INSTALLATION ONLY Insert short end of N...

Page 5: ...ion Attach power cable to hood using appropriate clamp 16 Hang hood from 4 mounting screws driven part way into cabinet locations shown in illustrations under PREPARE HOOD LOCATION Mounting screws are...

Page 6: ...y Broan NuTone faulty installation or installation contrary to recommended installation instructions The duration of any implied warranty is limited to the one year period as specified for the express...

Page 7: ...ors mounting hardware 9 97017728 Damper Duct Connector includes mounting hardware 10 97018229 Light Panel LH White includes mounting hardware 97018230 Light Panel LH Black includes mounting hardware 9...

Page 8: ...lamb 3 Nettoyez souvent la hotte Ne laissez pas la graisse s accumuler sur le ventilateur ou les filtres 4 Utilisez des casseroles de dimension appropri e Utilisez toujours une batterie de cuisine ada...

Page 9: ...ent Pour une vacuation verticale ou horizontale installez les conduits entre un capuchon de toit ou un capuchon mural Pour obtenir les meilleurs r sultats utilisez un minimum de coudes et de transitio...

Page 10: ...vis de c t 1 TIRER VERS LE BAS 2 SOULEVER Remarquez la cale de bois et la vis suppl mentaires pr s de l avant de l armoire sur la ligne centrale de l armoire PANNEAU INF RIEUR CONDUIT HORIZONTAL 8 3...

Page 11: ...DE LA HOTTE 9 INSTALLATION SANS CONDUIT SEULEMENT Enlevez les 2 vis retenant la plaque non canalis e au caisson non canalis et retirez la plaque 10 INSTALLATION SANS CONDUIT SEULEMENT Ins rez la peti...

Page 12: ...i re de la hotte INSTALLATION DE LA HOTTE 15 Acheminez le fil d alimentation lectrique du panneau lectrique jusqu l emplacement de la hotte Fixez le c ble la hotte avec le connecteur appropri 16 Suspe...

Page 13: ...vaise installation ou une installation contraire aux instructions recommand es La dur e de toute garantie tacite est limit e cette p riode d un an tel que stipul pour la garantie expresse Certains ter...

Page 14: ...quincaillerie de montage 9 97017728 Clapet raccord de conduit incluant la quincaillerie de montage 10 97018229 Panneau d clairage blanc GAUCHE comprend la quincaillerie de montage 97018230 Panneau d...

Page 15: ...s Suzette cerezas Jubilee bistec con pimienta flameado 3 Limpie frecuentemente los ventiladores No permita la acumulaci n de grasa en el ventilador ni en el filtro 4 Use una cacerola del tama o adecua...

Page 16: ...s lo conducto de 3 x 10 pulg 8 3 x 25 4 cm Para descarga vertical u horizontal coloque la red de conductos entre el lugar donde va a instalar la campana y el tap n de techo o tap n de pared Para obte...

Page 17: ...piente inferior y los tornillos 1 JALAR HACIA ABAJO 2 LEVANTAR HACIA FUERA Observe la cu a de madera adicional y el tornillo de montaje cerca del frente del gabinete sobre la l nea central del gabinet...

Page 18: ...ES SIN CONDUCTOS Quite 2 tornillos que sostienen la placa sin conducto al pleno sin conducto y quite la placa 10 NICAMENTE EN INSTALACIONES SIN CONDUCTOS Inserte el extremo corto de la placa sin condu...

Page 19: ...servicio y la campana Conecte el cable el ctrico a la campana con la abrazadera apropiada 16 Cuelgue la campana de los 4 orificios de montaje insertados parcialmente en las posiciones del gabinete mo...

Page 20: ...de las instrucciones de instalaci n recomendadas La duraci n de cualquier garant a impl cita se limita al per odo de un a o como se especifica para la garant a expresa Algunos estados no permiten limi...

Page 21: ...de montaje 9 97017728 Conector del regulador de tiro conducto incluye las piezas de montaje 10 97018229 Panel de luces IZQUIERDO color blanco incluye piezas de montaje 97018230 Panel de luces IZQUIERD...

Reviews: