Section D – Electrical Components
Lower Limit Switch
REMOvE AND REPLACE
This switch sets the lower travel limit for the ram
mechanism.
Remove the back panel from the cabinet cover (see
1.
Access to Components, Remove Cabinet Cover).
SCREWS
Remove two Phillips head screws and the switch
2.
from the center stabilizer plate.
Noting their locations, transfer the wires to the
3.
replacement switch.
Install the switch and secure with two Phillips head
4.
screws.
Motor Centrifugal Switch
Assembly
REMOvE AND REPLACE
This switch reverses the motor when peak load is
reached.
SWITCH
POWER UNIT
MECHANISM
SCREWS
Remove the control panel assembly from the front of
1.
the unit (see Control Panel Assembly, Remove and
Re-install).
SCREWS
Remove two Phillips head screws and the switch
2.
from the bottom of the motor.
Noting their locations, transfer the wires to the
3.
replacement switch.
Install the switch and secure with two Phillips head
4.