background image

15

25 po

63,5 cm

Che

vr

on

3 po

7,6
cm

Ø

Ø

Ø

Ø

29½ po

74,9 cm

20 po

50,8 cm

14

11

/

16 

po

37,3 cm

14

5

po

37,1 cm

ENLEVER

LES

BARDEAUX

Trou de 1¼ po

(3,2 cm)

Avant-trou
(centré entre les chevrons)

Trou de

11 po

(27,9 cm)

14

11

/

16 

po

37,3 cm

20 po

50,8 cm

29½ po

74,9 cm

Che

vr

on

Avant-trou
(centré entre les chevrons)

Trou de 1¼ po

(3,2 cm)

ENLEVER

LES

BARDEAUX

Trou de

11 po

(27,9 cm)

20½"

1"

2,5
cm

Ø

Ø

20½"

52,1 cm

Ø

Ø

18 po

45,7 cm

12

11

/

16

"

18 po

45,7 cm

12

11

/

16 

po

32,2 cm

20½ po

52,1 cm

1po

2,5
cm

Avant-trou

(centré entre les

chevrons)

ENLEVER LES

BARDEAUX

Trou de

11 po (27,9 cm)

Che

vr

on

Trou de
1¼ po 3,2 cm
de diá.

12

5

/

po

32,1 cm

Trou de
1¼ po 3,2 cm
de diá.

ENLEVER LES

BARDEAUX

Trou de

11 po (27,9 cm)

12

11

/

16 

po

32,2 cm

12

5

/

po

32,1 cm

Che

v

ro

n

Che

vr

onon

Che

vr

on

Avant-trou

(centré entre les

chevrons)

21 po

53,3 cm

21 po

53,3 cm

1. Choisissez l’emplacement sur un mur

extérior. Assurez-vous qu’aucun montant,

tuyau ou fil ne court dans l’ouverture prévue.

2. De l’intérieur, marquez et percez un 

avant-

trou

 centré entre les 

montants du mur

.

1. Positionez le ventilateur sur la pente arrière du toit.

Placez-le de manière à minimiser la longueur des
conduits. L’emplacement doit être dépourvu
d’obstacles (câble de télévision, fils électriques,
etc.). si le dessus du ventilateur est à égalité avec
le faîte du toit, il ne sera pas visible de la rue.
Rappelez-vous la position approzimative du
ventilateur lorsque vous travaillerez à l’intérieur du
grenier.

2. Marquez et percez un 

avant-trou

 centré entre les

chevrons du toit

.

INSTALLATIONS SUR UN TOIT

PRÉPARATION DE
L’INSTALLATION

PRÉPARATION DE
L’INSTALLATION

3. De l’extérieur, utilisez l’avant-trou comme point de

départ pour tracer le plan d’installation:

A. Avec un té, mesurez 12

5

/

8

 po (32,1 cm) à gauche de

l’avant-trou, puis 12

12

/

16

 po (32,2 cm) vers le haut

pour localiser le coin supérieur gauche du plan.

B. En partant du coin supérior gauche, tracez le rect-

angle à découper (21 po L x 20½ po H - 53,3 x 52,1
cm) et n’enlevez que les bardeaux de cette surface.

C. Tracez un 

trou de 11 po (27,9 cm) de diamètre

centré sur l’avant-trou. Découpez ce trou dans le
panneau de la couverture.

D. Tracez et

découpez
un 

trou de

1¼ po (3,2
cm) de
diamètre

 à

travers le
panneau
de la
couverture
à l’endroit
illustré.

4. Pour une installation sur un toit plat, bâtissez un

cadre qui permettra de monter le ventilateur selon
une pente d’au moins 2/12. La sortie du ventilateur
sera dirigée vers le bas.

29½ po

(74,9 cm)

2 po

(5,1 cm)

7 po

(17,8 cm)

2 po

(5,1 cm)

25 po

(63,5 cm)

INSTALLATIONS SUR UN MUR

3. De l’exterieur, utilisez l’avant-trou comme

point de départ pour tacer le plan d’installation:

A. Avec un té, mesurez 14

5

/

8

 po (37,1 cm) à

gauche de l’avant-trou, puis 14

11

/

16

 po (37,3

cm) vers le haut pour localiser le coin supérieur

gauche du plan.

B. En partant du coin supérieur gauche, tracez

le rectangle à découper (25 po L x 29½ po H

- 63,5 x 74,9 cm) et n’enlevez que le parement

de cette surface.

C. Tacez un 

trou de 11 po (27,9 cm) de

diamètre

 centré sur l’avant-trou. Découpez

ce trou cans le mur.

D. Tracez et découpez un 

trou de 1¼ po (3,2

cm) de diamètre

 à travers le mur à l’endroit

illustré.

Summary of Contents for Best EB15

Page 1: ...BEST BY BROAN P O BOX 140 HARTFORD WI 53027 Model EB15 EXTERIOR MOUNTED BLOWER FOR USE WITH BEST BY BROAN K210A OR K260A SERIES RANGE HOODS...

Page 2: ...rely fas ten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordancewithallapplicablecodesand standar...

Page 3: ...ove only the shingles in this area C Mark an 11 diameter hole centered on the guide hole Cut this hole through the roof board s D Mark and cut a 1 diameter hole through the roof board s w h e r e show...

Page 4: ...wiring beingused Connectblacktoblue white to brown and the green or bare wire to grounding screw 9 Replace cover and screws Do not pinch wiring under the cover 10 Make sure damper opens and closes fr...

Page 5: ...warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you...

Page 6: ...2 99100531 FoamSeal 3 98009539 MotorSupport 4 98009541 Damper Flap 2 req 5 99140145 Damper Spring 2 req 6 98009537 Grille 7 99080479 BlowerAssembly 8 99271203 Capacitor 9 99271221 WireAssembly 10 9910...

Page 7: ...BEST BY BROAN P O Box 140 HARTFORD WI 53027 Modelo EB15 VENTILADOR DE MONTAJE EXTERIOR PARA USARSE CON LAS COMPANAS BEST BY BROAN DE ESTUFA SERIES K210A O K260A...

Page 8: ...panel de servicio una etiqueta de advertencia prominente 3 El trabajo de instalaci n y el alambrado el ctrico deben llevarse a cabo por personal calificado de acuerdo con todos los c digos y las norma...

Page 9: ...EJAS de di Orificio de 11 27 9 cm de di Viga del techo Viga del techo Viga del techo Orificio de 1 3 2 cm de di 125 8 32 1 cm 125 8 32 1 cm 21 53 3 cm 3 Desde el exterior utilice el orificio gu a como...

Page 10: ...co de1 3 2cm dedi mentro quedealineadoconelorificiodelacajadeconexiones 3 Monte el ventilador en la pared con los seis 6 tornillosqueseproporcionan Serecomiendaque secoloquenlostornillosenelinteriorde...

Page 11: ...odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitac on antes mencionada...

Page 12: ...1 0 16 sereq 4 15 99250958 Arandeladeseguridad dentadaint sereq 5 16 99150506 Tornillo 12 24x 312SLTHWH 2 17 99270461 Pinzaparaelcord n 18 99260477 TuercaWhiz 20 sereq 9 19 99150471 Tornillodeconexi n...

Page 13: ...BEST BY BROAN P O Box 140 HARTFORD WI 53027 Mod le EB15 VENTILATEUR MONTAGE EXT RIEUR UTILISER AVEC LES HOTTES BEST BY BROAN DE S RIE K210A OU K260A...

Page 14: ...ersonnes qualif es selon tous le codes et touteslesnormesenvigueur ycomprisceuxet cellesconcernantlesconstructions talonn es contre le feau 4 Il faut suffisamment d air pour qu une bonne combustionetu...

Page 15: ...z l int rieurdu grenier 2 Marquez et percez un avant trou centr entre les chevronsdutoit INSTALLATIONS SUR UN TOIT PR PARATION DE L INSTALLATION PR PARATION DE L INSTALLATION 3 Del ext rieur utilisezl...

Page 16: ...st align avec celui de la bo te de c blage 3 Fixez le ventilateur au mur avec les six 6 vis fournies Il est conseill que les vis soient pos es l int rieur du bo tier Au besoin percez des avant trous 4...

Page 17: ...Certains tats et certaines provinces no permettent pas la limitation de la dur e d une garantie implicite la limitation ci dessus peut dono ne pas s appliquer vous L ENGAGEMENT DE BROAN DE R PARER OU...

Page 18: ...99150506 Vis 12 24 x 312 Hex fendue autotaraudeause 2 17 99270461 Bridedecordon 18 99260477 crou rondelle 20 9 n ces 19 99150471 Vis de mise la terre 10 32 x T te fendue hex 2 n ces 20 99160411 Vis 2...

Page 19: ...19...

Page 20: ...20 99042940C...

Reviews: