background image

2

 

 READ   AND   SAVE   THESE   INSTRUCTIONS

WARNING

Refrigeration and Air Conditioning Engi-

neers (ASHRAE), and the local code

authorities.

5. When cutting or drilling into wall, or ceil-

ing, do not damage electrical wiring or

other hidden utilities.

6. Ducted fans must always be vented to

the outdoors.

7. To reduce risk of fire, use only metal

ductwork.

8. This unit must be grounded.

CAUTION

1. For general ventilating use only. Do not

use to exhaust hazardous or explosive

material and vapors.

2. To avoid motor bearing damage and

noisy and/or unbalanced impellers, keep

drywall spray, construction dust, etc. off

power unit.

3. Please read specification label on prod-

uct for further information and require-

ments.

4. Electrical circuit, including speed control,

(if used), must be rated 6 AMPS mini-

mum.

WARNING

TO REDUCE THE RISK OF FIRE, ELEC-
TRIC  SHOCK, OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:

1. Use this unit only in the manner intended

by the manufacturer. If you have ques-

tions, contact the manufacturer at the

address or telephone number listed in

the warranty.

2. Before servicing or cleaning unit, switch

power off at service panel and lock the

service disconnecting means to prevent

power from being switched on acciden-

tally. When the service disconnecting

means cannot be locked, securely fas-

ten a prominent warning device, such as

a tag, to the service panel.

3. Installation work and electrical wiring

must be done by a qualified person(s) in

accordance with all applicable codes and

standards, including fire-rated construc-

tion codes and standards.

4. Sufficient air is needed for proper com-

bustion and exhausting of gases through

the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the

heating equipment manufacturer's

guideline and safety standards such as

those published by the National Fire

Protection Association (NFPA), and the

American Society for Heating,

INSTALLER: Leave This Manual With

The Homeowner.

HOMEOWNER: Use And Care

Information On Page 6.

SPECIFICATIONS

MODEL

VOLTS

AMPS

CFM

DUCT SIZE

EB15

120

3.8

1500

10 " DIA.

1. Locate the blower so the length of the

duct run and number of elbows are kept

to a minimum.

2. Where possible, blower

should be centered be-

tween wall studs or roof

rafters.

3. Avoid pipes, wires, or

other ductwork that may

be running through the

wall.

4. Attach mounting plate to

top of hood.

5. Install 10” dia. ductwork

and 120 VAC house wir-

ing between blower lo-

cation and hood location.

ALL INSTALLATIONS

PLAN THE INSTALLATION

MODEL EB15

EXTERIOR BLOWER

ALL HOOD

CANOPY

10" ROUND

DUCT

SOFFIT

ROUGH-IN

PLATE

21" or 24"

10"

or

18"

MODEL

EB15

EXTERIOR

BLOWER

WALL HOOD

CANOPY

10" ROUND DUCT

SOFFIT

ROUGH-IN

PLATE

21" or 24"

10"

or

18"

10" ROUND ELBOW

TYPICAL
ROOF MOUNTED
INSTALLATION

TYPICAL WALL

MOUNTED

INSTALLATION

Summary of Contents for Best EB15

Page 1: ...BEST BY BROAN P O BOX 140 HARTFORD WI 53027 Model EB15 EXTERIOR MOUNTED BLOWER FOR USE WITH BEST BY BROAN K210A OR K260A SERIES RANGE HOODS...

Page 2: ...rely fas ten a prominent warning device such as a tag to the service panel 3 Installation work and electrical wiring must be done by a qualified person s in accordancewithallapplicablecodesand standar...

Page 3: ...ove only the shingles in this area C Mark an 11 diameter hole centered on the guide hole Cut this hole through the roof board s D Mark and cut a 1 diameter hole through the roof board s w h e r e show...

Page 4: ...wiring beingused Connectblacktoblue white to brown and the green or bare wire to grounding screw 9 Replace cover and screws Do not pinch wiring under the cover 10 Make sure damper opens and closes fr...

Page 5: ...warranty is limited to the one year period as specified for the express warranty Some states do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you...

Page 6: ...2 99100531 FoamSeal 3 98009539 MotorSupport 4 98009541 Damper Flap 2 req 5 99140145 Damper Spring 2 req 6 98009537 Grille 7 99080479 BlowerAssembly 8 99271203 Capacitor 9 99271221 WireAssembly 10 9910...

Page 7: ...BEST BY BROAN P O Box 140 HARTFORD WI 53027 Modelo EB15 VENTILADOR DE MONTAJE EXTERIOR PARA USARSE CON LAS COMPANAS BEST BY BROAN DE ESTUFA SERIES K210A O K260A...

Page 8: ...panel de servicio una etiqueta de advertencia prominente 3 El trabajo de instalaci n y el alambrado el ctrico deben llevarse a cabo por personal calificado de acuerdo con todos los c digos y las norma...

Page 9: ...EJAS de di Orificio de 11 27 9 cm de di Viga del techo Viga del techo Viga del techo Orificio de 1 3 2 cm de di 125 8 32 1 cm 125 8 32 1 cm 21 53 3 cm 3 Desde el exterior utilice el orificio gu a como...

Page 10: ...co de1 3 2cm dedi mentro quedealineadoconelorificiodelacajadeconexiones 3 Monte el ventilador en la pared con los seis 6 tornillosqueseproporcionan Serecomiendaque secoloquenlostornillosenelinteriorde...

Page 11: ...odo de un a o como se especifica en la garant a expresa Algunos estados no permiten limitaciones en cuanto al tiempo de expiraci n de una garant a impl cita por lo que la limitac on antes mencionada...

Page 12: ...1 0 16 sereq 4 15 99250958 Arandeladeseguridad dentadaint sereq 5 16 99150506 Tornillo 12 24x 312SLTHWH 2 17 99270461 Pinzaparaelcord n 18 99260477 TuercaWhiz 20 sereq 9 19 99150471 Tornillodeconexi n...

Page 13: ...BEST BY BROAN P O Box 140 HARTFORD WI 53027 Mod le EB15 VENTILATEUR MONTAGE EXT RIEUR UTILISER AVEC LES HOTTES BEST BY BROAN DE S RIE K210A OU K260A...

Page 14: ...ersonnes qualif es selon tous le codes et touteslesnormesenvigueur ycomprisceuxet cellesconcernantlesconstructions talonn es contre le feau 4 Il faut suffisamment d air pour qu une bonne combustionetu...

Page 15: ...z l int rieurdu grenier 2 Marquez et percez un avant trou centr entre les chevronsdutoit INSTALLATIONS SUR UN TOIT PR PARATION DE L INSTALLATION PR PARATION DE L INSTALLATION 3 Del ext rieur utilisezl...

Page 16: ...st align avec celui de la bo te de c blage 3 Fixez le ventilateur au mur avec les six 6 vis fournies Il est conseill que les vis soient pos es l int rieur du bo tier Au besoin percez des avant trous 4...

Page 17: ...Certains tats et certaines provinces no permettent pas la limitation de la dur e d une garantie implicite la limitation ci dessus peut dono ne pas s appliquer vous L ENGAGEMENT DE BROAN DE R PARER OU...

Page 18: ...99150506 Vis 12 24 x 312 Hex fendue autotaraudeause 2 17 99270461 Bridedecordon 18 99260477 crou rondelle 20 9 n ces 19 99150471 Vis de mise la terre 10 32 x T te fendue hex 2 n ces 20 99160411 Vis 2...

Page 19: ...19...

Page 20: ...20 99042940C...

Reviews: