background image

Page 4

MODELS  764BN • 764RB • 764WH

USE AND CARE

USE AND CARE

WARNING: DISCONNECT ELECTRICAL POWER SUPPLY AND 

LOCK OUT SERVICE PANEL BEFORE CLEANING OR SERVICING 

THIS UNIT.

BULB REPLACEMENT

Remove glass shade. Replace bulbs as required. Replace glass 

shade.
Use 60-watt (maximum), B10 type, candelabra bulbs.

MOTOR LUBRICATION

The motor is permanently lubricated. Do not oil or disassemble motor.

SERVICE PARTS

WARRANTY

99044527C

 KEY  PART NO. 

DESCRIPTION

  1 

99527180  Glass Shade (764BN, 764WH)

  99527181  Glass Shade (764RB)  

 

  2 

97018137  Shade Mounting Hardware (764BN)

  97018140  Shade Mounting Hardware (764RB)

  97018141  Shade Mounting Hardware (764WH)  

  3 

99260558  Motor Nut, Hex Lock #8-32 (3 req.)  

  4 

99250959  Motor Washer (3 req.)

  5 

99100491  Motor Grommet (3 req.)

  6 

99150583  Grille Screw 

   

  7 

97016722  Motor  

 

  8 

99020276  Blower Wheel 

   

  9 

99270981  Lamp Receptacle, White  

 

  10 

99270982  Motor Receptacle, Black  

 

  11 

98009612  Wiring Panel 

   

  12 

99150471  Ground Screw 

   

  13 

99170245  Screw, #8-18 X 3/8”    

  14 

98008868  Wiring Plate 

   

  15 

97014185  Damper / Duct Connector  

 

  16 

97014922  Housing Assembly

  17 

97016630  Motor Plate

  A 

97018133  Light Fixture Assembly (764BN)

  97018132  Light Fixture Assembly (764RB)  

  97018136  Light Fixture Assembly (764WH)

  

  (Light Fixture Assembly includes Glass  

  

  Shade (Key No. 1), Mounting Hardware  

  

  (Key No.2), and Grille Pan Assembly B 

  B 

99391086  Grille Pan Assembly (764BN)

  99391087  Grille Pan Assembly (764RB)

  99391088  Grille Pan Assembly (764WH)  

  C 

97016671  Blower Assembly 

   

  

  (Includes Key Nos. 3 thru 8)  

  D 

97015171  Wire Panel Assembly  

 

  

  (Includes Key Nos. 9, 10, 11) 

Order replacement parts by “PART NO.” - not by “KEY NO.”

BROAN-NUTONE ONE YEAR LIMITED WARRANTY

Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of origi-

nal purchase. THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A 

PARTICULAR PURPOSE.

During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.

THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES. This warranty does not cover (a) normal maintenance and service or (b) any products or parts which 

have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty installation or installation contrary to recommended installation instructions.

The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above 

limitation may not apply to you.

BROAN-NUTONE’S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE’S OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. 

BROAN-NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. 

Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.

To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any 

defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.

Broan-NuTone LLC    Hartford, Wisconsin    www.broan.com    800-558-1711

CLEANING

TO CLEAN GLASS SHADE AND GRILLE PAN:

Remove glass shade. Shade can be wiped clean with a mild deter-

gent solution or glass cleaner and dried with a soft cloth. Remove 

2 bulbs. Grille pan may be gently vacuumed and wiped clean with 

a soft cloth. Never use abrasive cloth, steel wool pads or scouring 

powders on glass shade or grille pan. METAL AND ELECTRICAL 

PARTS SHOULD NEVER BE IMMERSED IN WATER.

TO CLEAN FAN ASSEMBLY:

Remove grille pan and unplug fan assembly (black receptacle). 

Gently vacuum fan, motor and interior of housing.  METAL AND 

ELECTRICAL PARTS SHOULD NEVER BE IMMERSED IN WATER.

1

3

4

5

7

8

9

10

11

13

14

15

16

A

C

D

12

B

2

6

17

2

Summary of Contents for 764BN

Page 1: ...listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT C...

Page 2: ...possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1...

Page 3: ...L Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge...

Page 4: ...to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or par...

Page 5: ...rte que l on puisse l atteindre d une baignoire ou d une douche 8 Cet appareil doit tre reli une mise la terre 9 Cetappareilesthomologu U L TypeI C comporteuneprotection interne ATTENTION 1 Cet appare...

Page 6: ...s et de coudes 2 Positionnez les brides de montage contre la solive de sorte que le bas du bo tier affleure la surface finie du plafond Positionnement dans des plafonds de 1 6 cm 5 8 po 2 5 cm 1 po et...

Page 7: ...o tier dans l ouverture de sorte que son ar te inf rieure affleure la surface finie du plafond Clouez chaque bride la solive travers les trous en forme de serrure Pour assurer un fonctionnement silenc...

Page 8: ...es nos 3 8 D 97015171 Ensemble de panneau de c blage comprend rep res nos 9 10 11 Veuillez commander les pi ces de rechange par N PI CE et non par N REP RE GARANTIE LIMIT E D UN AN BROAN NUTONE Broan...

Page 9: ...ta unidad se debe conectar a tierra 9 Esta unidad est incluida en la lista de U L Tipo I C proteger inherente PRECAUCI N 1 Esta unidad debe usarse solamente para ventilaci n general No la utilice para...

Page 10: ...uede al ras del cielo raso terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubie...

Page 11: ...redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que...

Page 12: ...cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN NUTONE DE REPARAR O CAMBIAR A O...