3. Set housing aside and drive nails partially into joist at the 

top of both keyhole marks.

4. Hang housing from nails and pound nails tight. To ensure 

a noise-free mount, pound another nail through the top 

hole of each mounting tab.

INSTALL THE HOUSING 

(continued)

New Construction

Existing Construction

2. In attic, position mounting brackets against joist. Trace 

outline of housing on ceiling material.

1.  Choose the location for your fan/light in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

3. Set housing aside and cut ceiling opening slightly larger 

than marked.

INSTALL THE HOUSING

1. Choose the location for your fan in the ceiling. For best 

possible performance, use the shortest possible duct run 

and a minimum number of elbows.

2. Position mounting brackets against joist so that bottom  

edge of housing will be flush with finished ceiling.

Additional positioning feature for 5/8”, 1”, &

1-1/4” thick ceiling material:

Holes in corners of housing are labeled with various 

ceiling material thicknesses. Position housing so 

bottom edge of joist is visible through a matched 

set of holes. The housing is now in the proper 

position for that ceiling material thickness.

Additional  positioning  feature  for  1/2”  thick 

ceiling material:

Bend two tabs, on side of housing, 90

0

 outward. Lift 

housing until tabs contact underside of joist.

Mark the keyhole slot on both mounting brackets.

New Construction

5/8

1

1-1/4

TAB

HOLES

BOTTOM EDGE OF JOIST

- PLEASE NOTE -

THE  FOLLOWING  INSTALLATION  ILLUSTRATIONS 

SHOW 2 X 6 JOISTS. IF YOU HAVE A TRUSS OR “I”-JOIST 

INSTALLATION, MOUNT THE VENTILATOR TO THE AD-

DITIONAL FRAMING IN THE SAME MANNER. (Additional 

framing must be a 2x6 (minimum height).

Summary of Contents for 764BN

Page 1: ...listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT C...

Page 2: ...possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1...

Page 3: ...L Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge...

Page 4: ...to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or par...

Page 5: ...rte que l on puisse l atteindre d une baignoire ou d une douche 8 Cet appareil doit tre reli une mise la terre 9 Cetappareilesthomologu U L TypeI C comporteuneprotection interne ATTENTION 1 Cet appare...

Page 6: ...s et de coudes 2 Positionnez les brides de montage contre la solive de sorte que le bas du bo tier affleure la surface finie du plafond Positionnement dans des plafonds de 1 6 cm 5 8 po 2 5 cm 1 po et...

Page 7: ...o tier dans l ouverture de sorte que son ar te inf rieure affleure la surface finie du plafond Clouez chaque bride la solive travers les trous en forme de serrure Pour assurer un fonctionnement silenc...

Page 8: ...es nos 3 8 D 97015171 Ensemble de panneau de c blage comprend rep res nos 9 10 11 Veuillez commander les pi ces de rechange par N PI CE et non par N REP RE GARANTIE LIMIT E D UN AN BROAN NUTONE Broan...

Page 9: ...ta unidad se debe conectar a tierra 9 Esta unidad est incluida en la lista de U L Tipo I C proteger inherente PRECAUCI N 1 Esta unidad debe usarse solamente para ventilaci n general No la utilice para...

Page 10: ...uede al ras del cielo raso terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubie...

Page 11: ...redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que...

Page 12: ...cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN NUTONE DE REPARAR O CAMBIAR A O...

Reviews: