background image

Page 3

MODELS  764BN • 764RB • 764WH

FINIAL

NUT

GLASS

SHADE

GRILLE

PAN

ROD

WASHER

60 WATT

MAX.

B10 BASE

CANDELABRA

BULBS

(2 REQ.)

WASHER

B L K

V E N T
S W I T C H

B L U

B L K

W H T

W H T

W H T

L I G H T

( W H I T E )

G R D

V E N T

( B L A C K )

U N I T

S W I T C H   B O X

L I G H T
S W I T C H

L I N E

I N

B L K

R E D

W H T

G R D

SCHEMATIC WIRING DIAGRAM

SWITCH BOX

LIGHT

FAN

DUAL CONTROL

(purchase separately)

WHITE

BLACK

RED

GROUND
(bare)

WIRING

PLATE

120 VAC

LINE IN

BLUE

BLACK

RECEPTACLE

(FAN)

WHITE

RECEPTACLE

(LIGHT)

INSTALL THE HOUSING 

(continued)

ATTACH THE GRILLE PAN AND 
GLASS SHADE

INSTALL THE DUCTWORK

FLUSH

NOTE:

 The duct connec-

tor has a counter-balanced 

damper flap. The flap will be 

CONNECT THE WIRING

1.  Snap the damper/duct connector onto housing. Make sure 

that tabs on the connector lock into slots in housing. Top of 

damper/duct connector should be flush with top of housing.

2. Connect 4” round duct to damper/duct connector and 

extend duct to outside through a roof or wall cap. Check 

damper to make sure that it opens freely. Tape all duct 

connections to make them secure and air tight.

“open” approx. 1” when duct connector is attached to housing. 

This design permits insulation to be in direct contact with fan/

light housing per UL (Underwriters Laboratories) standards. 

The slightest backdraft, however, will close the damper flap, 

preventing air from entering unit or finished space.

4. Place housing in opening so that its bottom edge is flush  

with finished ceiling. Nail to joist through keyhole on both 

sides. To ensure a noise-free installation, drive another nail 

through the top hole of each mounting bracket. 

Existing Construction

5. Additional mounting holes are provided for installations 

where access from above is inconvenient or not possible. 

Nail or screw housing directly to joists or framing.

ADDITIONAL

MOUNTING

HOLES

1.  Locate the grille pan 

over the fan housing 

and connect the wiring 

harness plug into white 

receptacle in the fan 

housing.

2. Insert rod through center 

hole of grille pan. Use 

washer between collar 

on rod and pan.

3. Thread rod onto grille 

screw in housing, until 

pan is tight against 

ceiling. Do not over-

tighten mounting rod.

4. Install bulbs. Use 60-

watt (maximum), B10 

type, candelabra bulbs. 

5. Place washer and glass 

shade over mounting 

rod and align shade 

onto grille pan. Secure 

glass shade to grille pan 

with finial cap and nut as 

shown.

6. Restore electrical power 

and check operation of 

the unit.

1. Wire unit following diagram 

above. Run electrical cable as 

direct as possible to unit. Do not 

allow cable to touch sides or top of unit after installation is 

complete. 

GRILLE 

PAN

GRILLE

SCREW

WASHER

ROD

WASHER

GLASS SHADE

FINIAL

NUT

Summary of Contents for 764BN

Page 1: ...listed Type I C inherently protected CAUTION 1 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 2 This product is designed for installation in FLAT C...

Page 2: ...possible duct run and a minimum number of elbows 2 Position mounting brackets against joist so that bottom edge of housing will be flush with finished ceiling Additional positioning feature for 5 8 1...

Page 3: ...L Underwriters Laboratories standards The slightest backdraft however will close the damper flap preventing air from entering unit or finished space 4 Place housing in opening so that its bottom edge...

Page 4: ...to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES This warranty does not cover a normal maintenance and service or b any products or par...

Page 5: ...rte que l on puisse l atteindre d une baignoire ou d une douche 8 Cet appareil doit tre reli une mise la terre 9 Cetappareilesthomologu U L TypeI C comporteuneprotection interne ATTENTION 1 Cet appare...

Page 6: ...s et de coudes 2 Positionnez les brides de montage contre la solive de sorte que le bas du bo tier affleure la surface finie du plafond Positionnement dans des plafonds de 1 6 cm 5 8 po 2 5 cm 1 po et...

Page 7: ...o tier dans l ouverture de sorte que son ar te inf rieure affleure la surface finie du plafond Clouez chaque bride la solive travers les trous en forme de serrure Pour assurer un fonctionnement silenc...

Page 8: ...es nos 3 8 D 97015171 Ensemble de panneau de c blage comprend rep res nos 9 10 11 Veuillez commander les pi ces de rechange par N PI CE et non par N REP RE GARANTIE LIMIT E D UN AN BROAN NUTONE Broan...

Page 9: ...ta unidad se debe conectar a tierra 9 Esta unidad est incluida en la lista de U L Tipo I C proteger inherente PRECAUCI N 1 Esta unidad debe usarse solamente para ventilaci n general No la utilice para...

Page 10: ...uede al ras del cielo raso terminado Caracter stica adicional para la colocaci n en material de cielo raso de 5 8 1 6 cm 1 2 5 cm y 1 3 2 cm Los orificios que se encuentran en las esquinas de la cubie...

Page 11: ...redondo de 4 10 2 cm en el conector del regulador de tiro conducto y extienda el conducto hasta el exterior a trav s de una tapa de techo o de pared Revise el regulador de tiro para asegurarse de que...

Page 12: ...cita Algunos estados no permiten limitaci n a la duraci n de una garant a impl cita por lo que esta limitaci n tal vez no se aplica al caso suyo LA OBLIGACION DE BROAN NUTONE DE REPARAR O CAMBIAR A O...

Reviews: