background image

 

BroaMan MUX22 

Operating Manual 
Rev. 2.1 

 
 
 

 

 
 
 
 
 

 

 
 
 

 
 

 

 
 
 
 
 
 

 

Operating Manual for  

MUX22 

 

BroaMan device with Optocore® and SANE® integration 

 

© Copyright 2017 All rights reserved 

 

BROAMAN GmbH  

Lohenstr. 8 

82166 Munich-Gräfelfing 

Germany

Summary of Contents for MUX22

Page 1: ...oaMan MUX22 Operating Manual Rev 2 1 Operating Manual for MUX22 BroaMan device with Optocore and SANE integration Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Page 2: ...Page intentionally left blank ...

Page 3: ...ment Protect the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device s...

Page 4: ...and EN55103 2 Electromagnetic compatibility Product family standard for audio video and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for the use in moderate climate Ventilation Do not block or cover ...

Page 5: ...lked on crushed pinched or damaged in any other way Pay special attention to the plugs and the sockets of the device Fuse There is no fuse in the device The power supplies contain circuitry that protects the device from overload Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord Thi...

Page 6: ...ptical fibre cables are covered with the provided caps Do not place this device on an unstable table tripod cart etc The device may fall which can cause injury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device Servicing Do not attempt to service the device by yo...

Page 7: ... harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you will be required...

Page 8: ...Page intentionally left blank ...

Page 9: ...22 IVT IVT 24 MUX22 with RS422 special serial data interface 25 Device Details 26 BNC SDI Ports 26 IVT Intelligent Video Tunnel Input Module 26 IVT Intelligent Video Tunnel Output Module 26 Fiber Ports 26 Multiplexers 26 IC422 and IC485 Intercom Ports 26 ICAES AES3 Duplex Ports 26 IC444 Line Level I O and GPIO 27 FO four douplex optical MADI ports 27 BNC four douplex optical MADI ports 27 Optocore...

Page 10: ...0 Ordering Options 30 MUX22 IVT IC422 30 MUX22 IVT IC485 31 MUX22 IVT IC444 31 MUX22 IVT ICAES 32 MUX22 IVT MADI OPT 32 MUX22 IVT MADI BNC 33 Connector Pin Out 34 Connection Examples GPI GPO IC444 Module 38 Dimensions and Weight 40 Dimensions 40 Weight 40 Warranty and Liability 41 Summary of Warranty 41 How to Obtain Warranty Service 41 Declaration of Liability 41 Package Contents 42 Company Infor...

Page 11: ...ol For RTS intercom systems IC485 with 4 RTS compatible four wire intercom ports with serial control For systems requiring line level I O and GPIO IC444 with 4 Line Level inputs and outputs 4 GPI in and 4 GPI out and auxiliary power output For AES connectivity for e g AES EBU based intercoms ICAES with 4 AES3 inputs and outputs For MADI connectivity FO with 4 Duplex SC MADI Ports BNC with 4 Bi dir...

Page 12: ...ontrolled MUTE Red Input no function Output no signal routed to this output Signal Monitor LED for 8 3G HD SDI Channels IVT Intelligent Video Tunnel MR currently not used R33 currently not used VSP currently not used PEAK Red Optical power exceeds the maximum input level of the receiver LEVEL Yellow Optical power is in proper range and good condition SIGNAL Green Indicates SDI input output signal ...

Page 13: ... LED Green Indicates data activity RS232 connector RS232 D Sub 9 connection for remote control and firmware updates via PC LAN LINK LED S1 Ethernet communication is established via SANE 1 rear panel S2 Ethernet communication is established via SANE 2 rear panel UP There is another device with an enabled Ethernet port on the network L1 Ethernet communication is established via LAN 1 rear panel L2 E...

Page 14: ...AK Red Optical power exceeds the maximum input level of the receiver LEVEL Yellow Optical power is in proper range and good condition SIGNAL Indicates SDI input output signal presence MUTE Red Optical power is too low signal is muted LINK LED SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore L...

Page 15: ...are updates via PC LAN LINK LED S1 Ethernet communication is established via SANE 1 rear panel S2 Ethernet communication is established via SANE 2 rear panel UP There is another device with an enabled Ethernet port on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel Sample rate LED Yellow 44 1 48 88 2 96 176 4 1...

Page 16: ...K LED SL1 Communication is established via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the master device in the system OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Dis...

Page 17: ...nel S2 Ethernet communication is established via SANE 2 rear panel UP There is another device with an enabled Ethernet port on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel Sample rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Page 18: ...lished via SANE 1 rear panel SL2 Communication is established via SANE 2 rear panel OL1 Communication is established via Optocore LINK 1 rear panel OL2 Communication is established via Optocore LINK 2 rear panel Master LED Indicates the master device in the system OPTO LED Optocore communication is established SANE LED SANE communication is established Device ID Display The identification number I...

Page 19: ...lished via SANE 2 rear panel UP There is another device with an enabled Ethernet port on the network L1 Ethernet communication is established via LAN 1 rear panel L2 Ethernet communication is established via LAN 2 rear panel Sample rate LED Yellow 44 1 48 88 2 96 176 4 192 kHz ...

Page 20: ...UX1 Auxiliary duplex fiber port of internal WDM CWDM or DWDM module No 1 provides connectivity for external fiber devices such as Gigabit Ethernet switches or any other third party optical connection WDM port AUX2 Auxiliary duplex fiber port of internal WDM CWDM or DWDM module No 2 provides connectivity for external fiber devices such as Gigabit Ethernet switches or any other third party optical c...

Page 21: ...iber port of internal WDM CWDM or DWDM module No 1 provides connectivity for external fiber devices such as Gigabit Ethernet switches or any other third party optical connection WDM port AUX2 Auxiliary duplex fiber port of internal WDM CWDM or DWDM module No 2 provides connectivity for external fiber devices such as Gigabit Ethernet switches or any other third party optical connection POWER 1 and ...

Page 22: ...ted internally to SFP fiber transceivers that feed the specified CWDM or DWDM multiplexers WDM port COM1 Combined duplex fiber port of internal WDM CWDM or DWDM No 1 WDM port COM2 Combined duplex fiber port of internal WDM CWDM or DWDM No 2 WDM port AUX1 Auxiliary duplex fiber port of internal WDM CWDM or DWDM module No 1 provides connectivity for external fiber devices such as Gigabit Ethernet sw...

Page 23: ... 100 Mbit Ethernet LINK 1 Full duplex full bandwidth LC type optical interface for Optocore transmission SFP transceiver type depending on a specyfication LINK 2 Full duplex full bandwidth LC type optical interface for Optocore transmission SFP transceiver type depending on a specyfication LAN 1 100 Mbit RJ 45 Ethernet interface LAN 2 100 Mbit RJ 45 Ethernet interface ...

Page 24: ...ernally to SFP fiber transceivers that feed the specified CWDM or DWDM multiplexers WDM port COM1 Combined duplex fiber port of internal WDM CWDM or DWDM No 1 WDM port COM2 Combined duplex fiber port of internal WDM CWDM or DWDM No 2 WDM port AUX1 Auxiliary duplex fiber port of internal WDM CWDM or DWDM module No 1 provides connectivity for external fiber devices such as Gigabit Ethernet switches ...

Page 25: ...nd LINK2 Can be used for external fiber devices such as Ethernet switches see AUX1 2 SYNC In Tri Bi Level Sync or Word Clock software selectable input allowing synchronisation of Optocore devices network and sync signal distribution via the Optocore network from an external Sync Word Clock source SYNC Out Tri Bi Level Sync or Word Clock output for synchronization of external devices SANE 1 SANE RJ...

Page 26: ...tiplexing module s as required for the application Two external duplex fiber ports labelled LINK1 and LINK2 should be used for the external connection of Optocore fiber links to the built in CWDM DWDM module External auxiliary connections labelled AUX1 and AUX2 to the multiplexer module s can be specified for the connection to an external device such as a Gigabit Ethernet switch COM1 and COM2 port...

Page 27: ...er Channel based 8B10B NRZI coding Static time slots guarantee a synchronous transmission of all channels at all times without the use of dynamic bandwidth All signals connected to the intercom audio word clock sync and auxiliary ports of the device are transmitted simultaneously on one fiber while the second fiber of the LINK Interface receives data from the network The second LINK Interface pair...

Page 28: ...ice is equipped with a redundant power supply If the primary power supply were to fail due to disruption of the power source or in the case of a power supply malfunction the device will automatically switch over to the redundant power supply In order to make the power supply to the device redundant both power inputs must be connected to the mains supply if possible to different phases circuits or ...

Page 29: ...singlemode 80km Optocore is equipped by default with singlemode 1Gbit 10km transceiver The total optical loss should be less than 6dB between transceivers SANE Ports Use standard fully wired twisted pair cable Cat 5 Cat 5e Cat 6 terminated with RJ 45 connectors SANE utilizes all four pairs of the Cat 5 cable two pairs for standard Ethernet transmission and two pairs for the SANE synchronous audio ...

Page 30: ...rcom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x RS485 422 2 nd PSU 1 x 1310nm Aux M226242GP15002PA1 Mux22 IVT IC422 6 x 3G SDI IN 2 x 3G SDI OUT 4 x Clear Com 4 wire Intercom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x GPIO 2 nd PSU 1 x 1310nm Aux M222642R515002PA1 Mux22 IVT IC422 2 x 3G SDI IN 6 x 3G SDI OUT 4 x Clear Com 4 wire Intercom 2 x PSU 1 x SM Opt...

Page 31: ... M220845R515002PA1 Mux22 IVT IC485 8 x 3G SDI OUT 4 x RTS 4 wire Intercom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x RS485 422 2 nd PSU 1 x 1310nm Aux M220845GP15002PA1 Mux22 IVT IC485 8 x 3G SDI OUT 4 x RTS 4 wire Intercom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x GPIO 2 nd PSU 1 x 1310nm Aux MUX22 IVT IC444 Code Description M224444R515002PA1 Mux22 IVT I...

Page 32: ...Cat5 2 x LAN 4 x RS485 422 2 nd PSU 1 x 1310nm Aux M2226AEGP15002PA1 Mux22 IVT ICAES 2 x 3G SDI IN 6 x 3G SDI OUT 4 x AES3 Intercom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x GPIO 2 nd PSU 1 x 1310nm Aux M2280AER515002PA1 Mux22 IVT ICAES 8 x 3G SDI IN 4 x AES3 Intercom 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x RS485 422 2 nd PSU 1 x 1310nm Aux M2280AEGP15...

Page 33: ...VT MADI BNC 4 x 3G SDI IN 4 x 3G SDI OUT 4 x coax MADI I O 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x GPIO 2 nd PSU 1 x 1310nm Aux M2262MCR515002PA1 Mux22 IVT MADI BNC 6 x 3G SDI IN 2 x 3G SDI OUT 4 x coax MADI I O 2 x PSU 1 x SM Optocore Link 2 x SANE LAN MADI Cat5 2 x LAN 4 x RS485 422 2 nd PSU 1 x 1310nm Aux M2262MCGP15002PA1 Mux22 IVT MADI BNC 6 x 3G SDI IN 2 x 3G SDI OUT ...

Page 34: ...n Audio Out RS485 Use this pin out only for devices loaded with RTS Telex modules IC485 Shows the standard pin out for RS485 on the IC485 module Other pin outs may be specified at the time of order Pin 4 3 7 5 6 2 RJ 45 RJ45 is physically compatible with RJ11 and RJ12 connectors commonly used for RTS Telex panels and matrices Pin out Four Wire Intercom port TO MATRIX RTS Telex IC485 Channel Audio ...

Page 35: ...n 1 3 2 6 RJ 45 Pin out Line Level Inputs General Purpose Inputs IC444 Line Level Input General Purpose Input Aux Power 1 2 3 4 1 2 3 4 5V 12V Pin 21 23 25 27 29 31 33 35 19 37 3 5 7 9 11 13 15 17 GND 22 24 26 28 GND 30 32 34 36 D Sub 37 female Locking system acc to 4 40 UNC Pin out Line Level Outputs General Purpose Outputs IC444 Line Level Output General Purpose Output Aux Power 1 2 3 4 1 2 3 4 ...

Page 36: ...ion for the serial ports 1 2 3 4 1 2 3 4 Pin 3 6 10 13 1 4 11 14 7 8 9 GND GND GND GND 2 5 12 15 HD Sub 15 female Locking system acc to 4 40 UNC Pin out Auxilary Port 4 x Dual RS422 RS422 Input RX RS422 Output TX GND Software configurable for duplex RS485 operation Available as a factory fitted replacement option for the serial ports 1 2 3 4 1 2 3 4 10 11 12 13 14 15 16 17 18 Pin 1 3 5 7 19 21 23 ...

Page 37: ...ailable TXD RXD TXD RXD TXD RXD Pin 2 1 2 1 2 1 LC and SC connectors Pin out RS232 Port Channel RS232 Internally bridged Power Use standard RS232 cable male female to connect to PC RXD TXD 5VS GND Pin 3 2 1 4 6 7 8 9 5 D Sub 9 female Locking system acc to 4 40 UNC Pin out USB Port Channel USB GND USB B device connector VBUS D D Pin 1 2 3 4 Pin out DC Input Factory Fitted Option 12V GND Pin 4 1 XLR...

Page 38: ...BroaMan MUX22 Operating Manual Rev 2 1 38 Connection Examples GPI GPO IC444 Module ...

Page 39: ...Hz Impedance Output 5 Ω Input 75 Ω Drive level Output 1 Vpp Zero level Referring to GND 1 7 V Sense level Input 400 mVpp Remote Control Convention RS232 EIA TIA 232 57 600 Baud USB USB 2 0 Device 12 Mbit s LAN IEEE 802 3 10 100 Mbit s Power supply Type Switch mode universal input Mains voltage 100 240 V Frequency 50 60 Hz Power consumption Depending on the configuration of the device 32VA Max Secu...

Page 40: ...483 mm 19 inch height 44 mm 1 73 inch depth 200 mm 7 87 inch Rear panel width 438 mm 17 25 inch Weight Dependent on the configuration of each specific device Not more then 3kg Please note Modifications that serve the purpose of technical improvement may be carried out without prior notification ...

Page 41: ...ice When discovering a problem with an BROAMAN device you should contact either Broaman directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to BROAMAN BROAMAN will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest...

Page 42: ...ters RS232 cables and international electric cables which have been supplied on your request and your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest BROAMAN user manuals can be downloaded from the website http www broadcastmanufactur com index php support downloads Printed version of User Ma...

Page 43: ...ting Manual Rev 2 1 43 Company Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 89996460 Facsimile 49 0 89 89996479 Internet www BroaMan com Email inquiry broaman com ...

Reviews: