![Broadcom G610 Hardware Installation Manual Download Page 59](http://html.mh-extra.com/html/broadcom/g610/g610_hardware-installation-manual_2815739059.webp)
53-1004408-11 Installation Guide
Brocade
®
G610 Switch Hardware Installation Guide
Data Port Specifications (Fibre Channel)
Port Numbers
Media Type
Description
0 to 23
16G or 32G SFP+ optical ports
Switch mode (default): 8-, 16-, and 24-port configurations (8-port
increments through Ports on Demand [PoD] licenses); can be an F_Port,
an N_Port, or an E_Port.
Brocade Access Gateway default port mapping: 16 F_Ports, 8 N_Ports.
Fibre Channel Data Transmission Ranges
Port Speed (G)
Cable Size
(Microns)
Short Wavelength (SWL)
Long Wavelength (LWL)
Extended Long
Wavelength (ELWL)
50
150m (492 ft) (OM2)
380m (1264 ft) (OM3)
400m (1312 ft) (OM4)
N/A
N/A
62.5
70m (229 ft)
N/A
N/A
4
9
N/A
30 km (18.6 miles)
N/A
50
50m (164 ft) (OM2)
150m (492 ft) (OM3)
190m (623 ft) (OM4)
N/A
N/A
62.5
21m (68 ft)
N/A
N/A
8
9
N/A
10 km (6.2 miles)
25 km (15.5 miles)
N/A
50
35m (115 ft) (OM2)
100m (328 ft) (OM3)
125m (410 ft) (OM4)
N/A
N/A
62.5
15m (49 ft)
N/A
N/A
16
9
N/A
10 km (6.2 miles)
25 km (15.5 miles)
N/A
50
70m (230 ft) (OM3)
100m (328 ft) (OM4)
N/A
N/A
62.5
N/A
N/A
N/A
32
9
N/A
10 km (6.2 miles)
N/A
Serial Port Specifications (Pinout RJ-45)
NOTE
These specifications are for connectors on Brocade platforms only.
Pin
Signal
Description
1
Not supported
N/A
2
Not supported
N/A
3
UART1_TXD
Transmit data
4
GND
Logic ground
5
GND
Logic ground
6
UART1_RXD
Receive data
53-1004408-11
59
Broadcom
Summary of Contents for G610