WebSwitch Installation and Operation Manual
SETUP
8. Reboot Pulse Time:
This is the time (in seconds) that WebSwitchTM pulses the output ‘off’ and then
back ‘on’ to reboot the device connected to the outlet. WebSwitchTM executes the
reboot sequence when commanded by the user or when the automatic reboot con-
troller determines that it is time to reboot. This time can be set from 1 seconds to
60000 seconds (1000 minutes). The factory default for this setting is 10 seconds.
9. Failed Pings Before Reboot:
The device will be re-booted after this number of ping failures. This number can be
set between 1 and 255. The factory default for this setting is 5.
10. Max Reboot Attempts:
After the device has been re-booted this number of times without any successful
pings, it is assumed that there are problems with the device and WebSwitchTM will
no longer attempt to re-boot the device. At this point, WebSwitchTM will leave the
device on but will disable the auto re-boot feature. The auto re-boot feature will
remain disabled until a user enables it through the control page or WebSwitchTM is
powered down and powered up once again. This number can be set between 1 and
255. The factory default for this setting is 10.
2.3.5 Control Page Setup
Once WebSwitchTM is set up, it can be controlled and monitored using a web
browser by accessing its control page. Titles and basic contents of the control page
can be customized by setting the appropriate options on the ‘Control Page Setup’
page. Note that this setup page only affects the control web page and does not affect
the function of WebSwitchTM in any way.
Note that the option labeled Auto Reboot ON/OFF is available only when outputs
are configured for Auto Reboot mode as described in section 2.3.4. In the screen-
shot shown below, Out 1 has Auto Reboot set to No and Out 2 has Auto Reboot set
to Yes. This makes the Auto Reboot ON/OFF option available for Out 2 only.
1. Main Header Text:
This text will be displayed in the main header area of the control page. This field
can be up to 25 characters in length.