Terminal J7

8 - Connect the “Program on Hold” feed to the “MOH” terminals on J7.
9 - Set DIP switches according to the required operation, see chart below:

DIP switch settings on the Controller unit:  Firmware Version 1.08 or greater.

DIP – 1

CPC and current monitoring is turned off.  This allows for operation

of the unit without any phone lines plugged in.
DIP – 2

Two Hybrid operation.  The Hybrid and OPT relays control Hybrid

1, while the DLY and REC relays control Hybrid 2
DIP – 3

Auto-Answer.  If this is on the lines will auto answer and be placed

on hold.  This setting supercedes DIP-4.
DIP – 4

Re-defines the Flash button/LED as Auto-Answer on/off.  DIP-3

must be off for this to work.
DIP – 5

Hot line 5, unaffected by Busy Button.

DIP – 6

Hot line 6, unaffected by Busy Button.

DIP – 7

Hybrid 1 control.  OFF = Latch mode, ON = Pulse mode using

Hybrid and OPT.
DIP - 8Hybrid 2 control.  OFF = Latch mode, ON = Pulse mode using DLY and
REC relays.

DIP switch settings on the Switch Console:

DIP – 1-2

Address selection for remote Switch Consoles.  Each Switch Console

must have a different address:  00, 01, 10 or 11.  If two or more are the same there
will be data collisions and the system will not function properly.
DIP – 3

Turns off Ringer.  The ringer can be turned down with the volume

control but there will still be a low audible ring, which could be distracting to the
on-air talent.  This setting turns it off in software.
DIP – 4-7

Not used

DIP – 8

Test mode.  Used to test LED’s and pushbuttons on the Switch

Console.

10 - Connect the supplied 16vac @ 600ma wall transformer to J17, the power
connector on the TS-6 Controller.  

NOTE:  The Controller supplies power for all Switch Consoles.

11 - Follow the System operation guide below.

1

2

3

4

5

6

7

8

9

10

11

12

MOH

In-

MOH

In+

Shld

N.C.

COM

N.O.

N.C.

COM

N.O.

N.C.

COM

N.O.

N.O.

Com

N.C.

Dly

In

Gnd

Dly

In +

Dly

TTL

REC

In

Gnd

REC

In +

REC

TTL

OPT

In

Gnd

Opt

In +

Opt

TTL

13

14

15

16

17

18

19

20

21

22

23

24

------------------

REC

--------------

---------- HYBRID ----------      ------------- OPT --------------       ------------ DLY ------------

Summary of Contents for TeleSwitch Six

Page 1: ...or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2005 by Broadcast Tools Inc All rights reserved No part of this document may be reproduced or distributed without permission Visit www broadcasttools com for important product update information Controller firmware version 1 08 or above Switch Console firmware v...

Page 2: ...troduction 3 Safety Information 3 Who to Contact for Help 3 Product Description 4 Features 5 Switch Console Front Panel Description 5 Switch Console Rear Panel Description 5 Controller Rear Panel Description 5 Installation Guidelines 7 System Operation guide 10 Specifications 13 Warranty 14 Schematic Component and Hook up Layout Appendix 2 CONTENTS ...

Page 3: ...garding your product or you need assistance please con tact your distributor from whom you purchased this equipment If you would like more information about Broadcast Tools products you may reach us at Broadcast Tools Inc 131 State Street Sedro Woolley WA 98284 USA Voice 360 854 9559 Fax 360 854 9479 Internet Home Page www broadcasttools com E mail support broadcasttools com THANK YOU FOR CHOOSING...

Page 4: ...ephone set To answer a call directed to the hybrid press the button of the ringing line To answer a call with the telephone set press the PHONE button and then press the button of the ringing line To disconnect a call press the DROP button then the desired line button The conference feature allows button mash conferencing plac ing multiple lines on a single hybrid In addition to these standard fea...

Page 5: ...ogramming 8 position DIP switch Ring signal speaker level control may be defeated External 12 vdc power connector The Controller powers the Switch Consoles This connector is rarely used REAR PANEL DESCRIPTION SYSTEM CONTROLLER The Controller is equipped with the following connectors and controls Six RJ 11 s This is where the C O or fully functional loop start analog PBX extension lines are brought...

Page 6: ... into the TS 6 controller and the 16 VAC 600 ma wall transformer into a 120 Vac 50 60 Hz power source The rear panel power LED indicates when power is applied to the TS 6 controller while the Switch Consoles front panel power LED indi cates when power is applied to any of the Switch Consoles CE 220 Vac 50 60 Hz wall transformer OPTIONAL Remote Control Connector Refer to page 8 of this manual ...

Page 7: ...se refer to the appendix for connector locations Jump to STEP 4 STEP 3 RACK MOUNT EQUIPMENT Rack mount the Controller The RM 3 must be purchased to rack mount the Controller The Switch Console should be placed near the user STEP 4 CONNECT YOUR EQUIPMENT AND TELEPHONE LINES 1 Connect your Loop Start telephone lines to the first six RJ 11 s of the Controller As viewed from left to right The far left...

Page 8: ... DB 25 pin 3 to TS 6 Controller J7 pin 9 DB 25 pin 25 to TS 6 ControllerJ7 pin 8 DIP 2 must be ON to select the dual hybrid mode Gentner Digital Hybrid III DB 25 pin 1 Hybrid ON to TS 6 Controller J7 pin 6 DB 25 pin 2 Hybrid OFF to TS 6 Controller J7 pin 9 DB 25 pin 5 Ground to TS 6 Controller J7 pins 5 and 8 DIP 7 must be ON for pulse mode JK Audio Innkeeper 1 1R Innkeeper pin 6 Call to TS 6 Cont...

Page 9: ...h mode ON Pulse mode using Hybrid and OPT DIP 8Hybrid 2 control OFF Latch mode ON Pulse mode using DLY and REC relays DIP switch settings on the Switch Console DIP 1 2 Address selection for remote Switch Consoles Each Switch Console must have a different address 00 01 10 or 11 If two or more are the same there will be data collisions and the system will not function properly DIP 3 Turns off Ringer...

Page 10: ... the phone output it will switch to the Hybrid and the yellow LED will light The hybrid relay output pins 5 and 6 must be connected to the Hybrid for control When a new line is selected the con trol line will turn off for 500ms and back on again in order to re null the Hybrid The selected line will be placed on hold for 500ms to maintain loop current on the line and give the Hybrid enough time to ...

Page 11: ...r no loop current Flash Hook A Flash Hook can be generated on any line that is either off hook connected to the phone output or an active Hybrid line To generate a 500ms Flash Hook signal press the Flash button followed by the line button This button can have an alternate use if DIP 4 is on Refer to Auto Answer Record Control Pressing the REC button will cause the red record led to begin flashing ...

Page 12: ...owed by six ASCII characters 123456 where 1 is line 1 2 is line 2 etc and end with an ASCII Carriage Return The six possible states are R Ring detected C Current flow detected Y Hybrid P Phone H Hold L Loop connected Idle state A typical string would be LLRYPH cr Where lines 1 and 2 are idle connected to their loop outputs line 3 is ringing line 4 is connected to Hybrid 1 line 5 is connected to th...

Page 13: ...0 8 N 1 Call Screener Software Interfacing Telco Loop Thru RJ 11 LOOP START ONLY Switch Consoles RJ 45 Hybrid Control SPDT relay contacts Screw terminals Auxiliary Control SPDT relay contacts Screw terminals Remote Indicators Opto Isolated inputs Screw terminals MOH Program balanced audio input 0dbu 20k Screw terminals RS 232 DB 9 Female 9600 8 N 1 Power Requirements 16 Vac 600 ma 120 Vac 50 60 hz...

Page 14: ...THER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABIL ITY OR FITNESS FOR A PARTICULAR PURPOSE AND THE FOREGOING ALTERNATIVE REMEDIES SHALL BE EXCLUSIVE OF ALL OTHER REMEDIES THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGH...

Page 15: ... 5 LINE 6 LOOP THRU 1 LOOP THRU 2 LOOP THRU 3 LOOP THRU 4 LOOP THRU 5 LOOP THRU 6 TELCO CENTRAL OFFICE USERS PHONE SYSTEM FREE PC CALL SCREENER SOFTWARE REMOTE CONTROL TS 6 DESKTOP TS 6 DESKTOP TS 6 DESKTOP TS 6 DESKTOP SCREENER TELEPHONE or 2nd Hybrid 1st Hybrid APPENDIX ...

Reviews: