TS-6 Installation and Operation Manual
INSTALLATION
Terminal J7
8 - Connect the “Program on Hold” feed to the “MOH” terminals on J7.
9 - Set DIP switches according to the required operation, see chart below:
DIP switch settings on the Controller unit: Firmware Version 1.08 or greater.
DIP – 1
CPC and current monitoring is turned off. This allows for operation
of the unit without any phone lines plugged in.
DIP – 2
Two Hybrid operation. The Hybrid and OPT relays control Hybrid
1, while the DLY and REC relays control Hybrid 2
DIP – 3
Auto-Answer. If this is on the lines will auto answer and be placed
on hold. This setting supercedes DIP-4.
DIP – 4
Re-defines the Flash button/LED as Auto-Answer on/off. DIP-3
must be off for this to work.
DIP – 5
Hot line 5, unaffected by Busy Button.
DIP – 6
Hot line 6, unaffected by Busy Button.
DIP – 7
Hybrid 1 control. OFF = Latch mode, ON = Pulse mode using
Hybrid and OPT.
DIP - 8Hybrid 2 control. OFF = Latch mode, ON = Pulse mode using DLY and
REC relays.
DIP switch settings on the Switch Console:
DIP – 1-2
Address selection for remote Switch Consoles. Each Switch Console
must have a different address: 00, 01, 10 or 11. If two or more are the same there
will be data collisions and the system will not function properly.
DIP – 3
Turns off Ringer. The ringer can be turned down with the volume
control but there will still be a low audible ring, which could be distracting to the
on-air talent. This setting turns it off in software.
DIP – 4-7
Not used
DIP – 8
Test mode. Used to test LED’s and pushbuttons on the Switch
Console.
10 - Connect the supplied 16vac @ 600ma wall transformer to J17, the power
connector on the TS-6 Controller.
NOTE: The Controller supplies power for all Switch Consoles.
11 - Follow the System operation guide below.
1
2
3
4
5
6
7
8
9
10
11
12
MOH
In-
MOH
In+
Shld
N.C.
COM
N.O.
N.C.
COM
N.O.
N.C.
COM
N.O.
N.O.
Com
N.C.
Dly
In
Gnd
Dly
In +
Dly
TTL
REC
In
Gnd
REC
In +
REC
TTL
OPT
In
Gnd
Opt
In +
Opt
TTL
13
14
15
16
17
18
19
20
21
22
23
24
------------------
REC
--------------
---------- HYBRID ---------- ------------- OPT -------------- ------------ DLY ------------