TS-6 Installation and Operation Manual
INSTALLATION
INSTALLATION GUIDELINES
It is recommended that all cables connected to the TS-6 be looped through ferrite
cores to suppress RF. Surge protection with RF filtering such as the Tripp Lite “ISO-
BAR 4” is also suggested for the power transformer. The purchase of an inexpensive
uninterruptible power supply (UPS) will provide back up in case of power outages.
1. Inspection
2. Bench test and option set-up
3. Rack mount the controller with the optional RM-3, while the Switch
Console(s) are designed for desktop mounting.
4. Connect your external equipment.
5. Label the front panel of the Switch Console(s), if desired.
6. Connect the serial port to a PC’s com port and load the Free Windows OS
based “Call Screener” software which may be downloaded from our web site.
STEP 1: INSPECTION
Please examine your TS-6 carefully for any damage that may have been sustained
during shipping. If any is noted, please notify the shipper immediately and retain
the packaging for inspection by the shipper. The package should contain the TS-6
controller, TS-6 Switch Console, this manual, 16 VAC @ 600-ma controller power
wall transformer, CAT-5/6 interconnection cable and serial cable.
STEP 2: BENCH TEST
Note: Please refer to the appendix for connector locations. Jump to STEP 4
STEP 3: RACK MOUNT EQUIPMENT
Rack mount the Controller. The RM-3 must be purchased to rack mount the
Controller. The Switch Console should be placed near the user.
STEP 4: CONNECT YOUR EQUIPMENT AND TELEPHONE LINES
1 - Connect your “Loop Start” telephone lines to the first six RJ-11’s of the
Controller (As viewed from left to right).
The far left RJ-11 is line one.
NOTE: It is imperative that the Tip & Rings are wired correctly for the
conference operation to work.
2 - If you are planning on looping-thru your business telephone lines through the
TeleSwitch Six, the loop-thru RJ-11’s may be used for this feature.
3 - Connect the first Hybrid to the RJ-11 labeled “HYBRID”(The 13th RJ-11
from the left).
4 - Connect the call screener telephone or the 2nd Hybrid to the RJ-11 labeled
“Phone” (The 14th RJ-11 from the left).
5 - Connect the first Switch Console to the RJ-45 labeled “Desk Set 1”.
6 - Connect the second Switch Console to the RJ-45 labeled “Desk Set 2”.
7 - Connect the hybrids remote control according to the type of hybrid listed on
the next page.
CAUTION!
Installation of the TS-6
in high RF environ-
ments should be per-
formed with care.
Shielded cable is sug-
gested for all control,
audio inputs and out-
puts. All shields should
be tied to the “CHAS-
SIS GROUND” termi-
nal. The station
ground should be con-
nected to the chassis
ground screw located
behind J17 as viewed
from the rear. For
lightning protection,
check out
www.polyphaser.com
and www.itwlinx.com