ADMS 44.22 Installation and Operation Manual

OPERATION

ory has been erased from flash and the unit becomes inoperable except for the
ability to download new firmware.  Once an XModem transfer fails, the baud
rate of the unit reverts to the 9600 baud default for all subsequent serial com-
munications.  After a successful Download at 9600 baud, the unit reverts back
to its programmed baud rate.

4.5

Relay and Open Collector Commands

OR[r][x]

Set Relay State    (ACS 8.2)

Sets the state of relays K1 through K4.  In the Unlatched state the relays are
open, and in the Latched state they are closed.   The Pulse option causes the
relay to latch for the amount of time specified by the Relay Momentary Pulse
Length, then unlatch.  The Toggle option causes the relay to toggle on and off
with a 50% duty cycle equal to the Relay Momentary Pulse Length.  When a
relay is toggling, sending an Unlatch command stops the toggling and sets the
relay to its Unlatched state. 
[x]

L = Latch; P = Pulse; F = Unlatch; T = Toggle

Note: The toggle state is not stored in either Last Saved or User memory.

CR[ttt]

Set Relay Momentary Pulse Length    (ACS 8.2)

Sets the amount of time a relay is latched on when pulsed, and sets the 50% duty
cycle time when toggled.
[ttt]

Time Range = 1 ? 100 (0.1 to 10.0 seconds) 

OO[c][x]

Set Open Collector State     (ACS 8.2)

Sets the state of open collector outputs OC1 through OC9 when the unit is in
GPO Mode.  In Status Mode, the OC outputs are controlled by the front panel
switcher buttons, and the OO command returns an EEE<CR><LF>.  In the
Unlatched state the open collector outputs are logic high (Off), and in the
Latched state they are logic low (On).   The Pulse option causes the outputs to
latch for the amount of time specified by the Open Collector Momentary Pulse
Length, then unlatch.  The Toggle option causes the output to toggle on and off
with a duty cycle equal to the Open Collector Momentary Pulse Length.  When
an open collector is toggling, sending an Unlatch command stops the toggling
and sets the output to its Unlatched state. 
[x]

L = Latch; P = Pulse; F = Unlatch; T = Toggle

Note: The toggle state is not stored in either Last Saved or User memory.

CO[ttt]

Set Open Collector Momentary Pulse Length 

Sets the amount of time an open collector is latched on when pulsed, and sets
the 50% duty cycle time when toggled.
[ttt]

Time Range = 1 ? 100 (0.1 to 10.0 seconds) 

Summary of Contents for ADMS 44.22

Page 1: ...visions of this information or new editions may be issued to incorporate such changes Broadcast Tools is a registered trademark of Broadcast Tools Inc Copyright 1989 2007 by Broadcast Tools Inc All ri...

Page 2: ...ing 10 1 7 External Control 10 1 7 1 Remote Control GPI PIP Inputs 10 1 7 2 Status GPO Outputs 11 1 7 3 Relays 11 1 8 Program Monitoring 11 2 Setup Installation 12 2 1 Mounting 12 2 2 Euroblock Connec...

Page 3: ...4 4 3 Set up Commands 25 4 4 Reset and Firmware Update Commands 26 4 5 Relay and Open Collector Commands 28 4 6 Query Commands 29 4 7 Equalizer Commands 32 4 8 ALC Commands 33 4 9 Preset Management Co...

Page 4: ...lems please research your hardware software instruction manuals or contact the man ufacturers technical support department WHO TO CONTACT FOR HELP If you have any questions regarding your product or y...

Page 5: ...22 can be con trolled through RS 232 serial command from a standard ANSI terminal or dedicat ed serial control device as well as from front panel switches and remote control inputs on the rear The ADM...

Page 6: ...effect on any other connection Interlock Mode In Interlock Mode only one input can be connected to an output at a time Connecting an input to an output disconnects all others from that output Overlap...

Page 7: ...average level is above the target output level the gain is quickly reduced A built in limiter prevents program peaks from causing clipping The ALC can be enabled disabled on a chan nel by channel bas...

Page 8: ...n be individually enabled disabled Each band s center peaking or corner shelving frequency can be set from 20 Hz to 20 kHz for all supported sample rates except 32 kHz At a 32 kHz sample rate equalize...

Page 9: ...lave units are powered up in their factory default configurations both units are automatically synchronized the Master unit is set to use the Internal sample clock and the Slave to use the Master ADMS...

Page 10: ...an AES Error condition is detected on any digital input connected to Output 1 the unit sends an SD status message indicating which inputs have experienced AES errors since the last time the error regi...

Page 11: ...tus outputs represent a logical OR condition between the Output 1 and Output 1 front panel input connect LEDs that input channel When the Silence Sensor Alarm for Output 1 is triggered the last output...

Page 12: ...rom the terminal For balanced input operation connect the and conductors of the source to the ADMS 44 22 and input terminals For unbalanced operation connect the and Gnd conductors of the source to th...

Page 13: ...ture below AES Outputs 1 and 2 parallel Analog Outputs 1 and 2 When the Sample Rate is running at 88 2 or 96 kHz the AES inputs and outputs both run in AES sin gle wire double speed mode In single wir...

Page 14: ...y impedance mismatches between the cable and the input terminating resistor will increase the clock jitter and degrade the perform ance of the A D and D A converters The amount of degradation increase...

Page 15: ...can be used to control the ADMS Procomm Bitcom VanDykeTM Windows HyperTerminal etc Use the following table to configure your terminal application or dedicated hardware controller device s com municati...

Page 16: ...d it enables its RS 232 transmit line responds to the terminal then immediately returns to the hi Z state to prevent transmit bus conflicts with the other ADMS 44 2 connected to the serial port Since...

Page 17: ...ally debounced and require a minimum input pulse duration of 60ms for the input status to be set true On The inputs labeled G are connected to internal ground and can be used for ground referencing ex...

Page 18: ...Switch The 10 posiiton rear panel options DIP switches control fundamental oper ating settings such as the Unit ID RS 232 Baud Rate and Master Slave Mode These switches are read only when the unit is...

Page 19: ...ir Unit ID set to 0 Baud Rate SW4 SW5 The RS 232 Baud Rate is set according to the following table Power Up Mode SW6 When the Power Up Mode switch is OFF the User Preset is automatically recalled when...

Page 20: ...e setup this switch must be set to Dual to receive audio from the Slave When the unit is a stand alone Master then this switch must be set to single In Slave mode this switch is ignored 2 14 Power Sup...

Page 21: ...de OP 2 Interlock Disconnected Input Fade OP 2 Overlap Disconnected ADMS 44 22 Front Panel Commands Result Disconnects Input from Output 1 Output 2 Disconnects all Inputs from both Outputs Dims Input...

Page 22: ...all other respects to OP 1 LED Pwr Ser Power Serial Activity Indicator Green Indicates when the unit is powered up and when there is serial Tx Rx activ ity present at the RS 232 port On Powered On Fla...

Page 23: ...vels for either Output 1 or Output 2 depending on the selected monitor source selection see above The PPM Meters use PPM ballistics which have an extremely fast response to signal peaks and a slow dec...

Page 24: ...s a command string are not allowed The following table details the allowed values for all command arguments Allowed values for com mand specific arguments are given in the description of the individua...

Page 25: ...ndows HyperTerminal ECHO returns all typed characters back to the terminal If ECHO is Off then any characters typed in the terminal will not be seen ECHO is valid only for units with ID 0 and by defau...

Page 26: ...Delay is set to Off the silence sensor is disabled ssss 2 9999 seconds 0 Off SST x Set Silence Sensor Threshold Sets the threshold below which an output s left and or right signal level must drop for...

Page 27: ...end the following text response Download new firmware D Reset unit R any other key to quit CR LF Press D to start the firmware download process Pressing any key other than D or R puts the unit back in...

Page 28: ...either Last Saved or User memory CR ttt Set Relay Momentary Pulse Length ACS 8 2 Sets the amount of time a relay is latched on when pulsed and sets the 50 duty cycle time when toggled ttt Time Range 1...

Page 29: ...are Version 1 00 CR LF Y Display Configuration Settings ACS 8 2 Returns a list of many of the unit s configuration settings in the following text readable format Sample Rate 48000 0 Sample Clock Inter...

Page 30: ...e uses the same format as that of the SPA command xx Port Range 0 16 0 All Ports yxx 0 Low 1 High Response S u P xx yxx CR LF SPA Display GPI PIP Port Status all ACS 8 2 Returns the current status of...

Page 31: ...AES error is latched for any given input no additional SD messages will be sent until the register is cleared with the AESR command If no AESR command is sent within 10s then the AES error register is...

Page 32: ...equalizer bands whose frequency is 15999 0 Hz will automatically be set to 15999 0 Hz Sending and EQF command to set any equalizer band greater than this frequency will return an EEE CR LF EQG ic b x...

Page 33: ...4 B1 Bypassed T Low Shelf G 0 0 F 20 0 Q 1 0 B2 Bypassed T Peaking G 0 0 F 1000 0 Q 1 0 B3 Bypassed T High Shelf G 0 0 F 20000 0 Q 1 0 4 8 ALC Commands ALCB1 ic x Enable Input ALC Enables input channe...

Page 34: ...nnel ALCs The ALC Threshold Level must be the ALC Target Output Level setting the ALC Threshold Level the ALC Target Output Level sets the ALC Threshold Level the ALC Target Output Level x Threshold L...

Page 35: ...Setting Sample Rate 48k Sample Clock Internal Master Master ADMS Slave Mix Mode Overlap Fade Rate 2 0s Relay Pulse Length 1 0s OC Pulse Length 1 0s Silence Sensor Delay 5s Silence Sensor Threshold 48...

Page 36: ...puts without affecting any other connections they behave identically in Mix Interlock and Overlap Modes For example issuing a non modal connect command in Interlock Mode allows two or more inputs to b...

Page 37: ...ltiple channels can be connected with no overlap condition In these circum stances the following additional rules govern the behavior of the switcher An overlap condition can exist only when at least...

Page 38: ...6 Mute Input In Output 2 ACS 8 2 Mutes a single input in Output 2 only 4 13 Audio Switcher Dim Commands Dim commands are non modal Dimming an input affects only the selected channel s regardless of t...

Page 39: ...ck and Overlap Modes initiates and automatic crossfade by fading down any connected inputs at the same rate FD ii Fade Down Input In Output 1 ACS 8 2 Fades a single input down in Output 1 only FU ii F...

Page 40: ...hold 48 0 12 Error Responses On 13 Terminal Echo On 14 Front Panel Lock Off D Set Factory Defaults Q Quit Enter Choice At the prompt enter the number corresponding to the setting you wish to change th...

Page 41: ...44 1 kHz 48 kHz 88 2 kHz 96 kHz AES Inputs 32 kHz to 96 kHz Single wire AES Input Impedance 110 ohm transformer balanced ac coupled AES Output Impedance 110 ohm transformer balanced dc coupled Analog...

Page 42: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Page 43: ...10 4 LT STEREO ANALOG INPUT 2 LT RT 10 4 RT 10 4 LT STEREO ANALOG INPUT 3 LT RT 10 4 RT 10 4 LT STEREO ANALOG INPUT 4 LT RT 10 4 RT AES SRC ALC EQ STEREO AES INPUT 2 AES SRC ALC EQ STEREO AES INPUT 3...

Reviews: