ACS5000 Installation Manual
Page 27
© 2017 Brivo Systems LLC. All rights reserved.
Rev 1
•
Connect the black reader wire to the GND terminal. This is the standard
Ground circuit for the reader.
•
Connect the blue (or yellow) reader wire to the BUZZ terminal. This is the
standard Buzzer circuit for the reader.
•
Connect the red reader wire to the 12VDC terminal. This pr12VDC to
power the reader.
•
Connect the orange reader wire to the GRN LED terminal. This is the green
LED circuit.
•
Connect the brown reader wire to the RED LED terminal. This is the red LED
circuit.
7.
Install MOVs.
WARNING: Noise Suppression
INSTALL THE TRANSIENT NOISE SUPPRESSION DEVICE (MOV) SUPPLIED WITH THE
CONTROL PANEL.
a)
Install the MOV across the conductors, as close as possible to the electric strike or
latch. This will normally be at the connection from the field-installed wiring to the pig
tail or screw terminals of the electronic strike or latch.
b)
Use the wire recommended by the manufacturer of the electric strike or latch. If no
wire is recommended, use a minimum of 18 AWG wire with sufficient strands for the
specific electronic strike or latch.
Wire INPUT OUTPUT BOARDs
Figure 17.
Wire INPUT OUTPUT BOARD