4
Selecting installation p
osition
Read completely, then follow step by step.
Indoor unit
Do not expose the indoor unit to
external
heat or steam.
Select a p
osition whe
re there are no obstacles
in front or around the unit.
Make sure that
the
condensat
e
drain
and pipework
can
be conveniently
routed
.
Do not install near doorway
s
.
Ensure that the
clearance to
the left and
the
right
of the unit is more than 12cm.
Use a stud finder to locate studs
for secure mounting and
prevent damage to the wall.
The indoor unit should be installed on the wall at a height of 2.
1
metres or more from the floor.
The indoor unit should be installed allowing a minimum clearance of 15cm from the ceiling
above
.
Any variations in pipe length may require adjustment to
the
refrigerant charge.
Install away from
direct sunlight.
T
he sun
may
fade the plastic cabinet and
affect its appearance.
If unavoidable,
adequate
sunlight prevention should be taken into consideration.
Outdoor unit
If an awning is built over the outdoor unit to
minimise
direct sunlight or rain exposure,
ensure that the
air paths and
heat radiation from the
condenser is
uninhibited
.
Ensure that the clearance
to
the back
of the
unit is more than 30cm and left side is
more
than 30cm.
The front of the unit should
have more than
1
00cm of clearance and the
connection side (right side) should have more
than 60cm of clearance.
Do not place animals
or
plants in the path of the air inlet or outlet.
Take the
unit’s operating
weight into account and select a
suitable position to minimise
noise
and vibration both internally and externally.
Select a
suitable position
so that the
a
ir
discharge
and noise from the
unit
do
es
not disturb neighbors.
If the outdoor unit is installed on a roof structure,
ensure it is installed on a secure
level
base
.
Ensure the roof structure and
securing
method are adequate for the unit location.
Consult local codes
and regulations
regarding roof mounting.
If the outdoor unit is installed on roof structures or external walls, this may result in
excessive noise and vibration,
it
may also be classed as a non serviceable installation
, and void
Roof installation:
INSTALLATION INSTRUCTIONS
More than 30cm
More than 60cm
More than 30cm
More than
1
00cm
Fig.2
More than 210cm
More than 15cm
More than 12cm
More than 12cm
Fig.1
1. Hi-Wall type
the manufacturers warranty.