9
INSTALLATION INSTRUCTIONS
3. Ducted type
Installation precautions
1. Determine the access route to the installation position.
2. To minimise damage, if possible, move the unit to the installation position with packaging intact.
3. Ensure all wiring is strictly in accordance with relevant local and national standards. Ensure that
insulation is in accordance with the standards, in case installation is on a metal part of the building.
Indoor unit installation
Refrigerant
pipe
Supply air outlet
Air return box
View
A
<500mm
Duct
>100mm
>200mm
>250mm
<3m
<1000mm
4. Avoid installing this system in the following locations, it may cause a malfunction.
(if unavoidable, please contact Brivis):
A. There is mineral oil present (as in the oil of machinery).
B. Highly corrosive environments. (Near the coast)
C. Highly caustic environments or near sulfuric gas. (Near hot spring.)
D. Areas where the voltage may fluctuate greatly.
E. On a mobile apparatus, caravan, mobile home, boat, bus etc...
F. In a kitchen or laundry with an overly steamy environment.
G. There are strong electromagnetic waves present.
H. There are combustible gases or materials present.
I. Highly acid or alkaline environments.
J. Other especially corrosive or arduous environments.
Ensure sufficient room for installation and maintenance.
Ensure that the installation is of sufficient strength to withstand the weight of the unit.
Ensure that the air inlet and outlet are not impeded and are not affected by outside air
Position so that the unit can distribute air effectively throughout the room.
Ensure that refrigerant pipes and condensate drain are accessible.
Avoid direct radiation from any external heat sources.
Installation location
Air return box
Supply air
<500mm
View
A
Function
Insulation pipe
Wired remote control
Large metal washers
Binding tape
Water outlet joint
Name
Qty.
No.
Outline
1
2
3
4
5
6
7
8
2
1
8
Pipe joint thermal insulation
Indoor unit fixing
Binding insulation pipe
Indoor unit remote control
9
10
Gasket
Copper nut
1
1
1
2
Connecting pipe
Outdoor unit drainage
Condensate drain hose
1
Indoor unit drainage
Outdoor unit drainage
Alkaline batteries
Remote signal receiver subassembly
(2)
1
Accessories
Supply
Outlet