25
7.2 Cooling Capacity Tables
Table 6 – Expanded Ratings: DONSC15Z7 / DINXU15Z7
Based on 736 L/s Rated Airflow
Table 7 - Expanded Ratings: DONSC13Z7 / DINXU13Z7
Based on 688 L/s Rated Airflow
Table 8 - Expanded Ratings: DONSC10Z7 / DINXU10Z7
Based on 561 L/s Rated Airflow
Return Air Temperature
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Air Temperature Entering
Outdoor Unit °C
21
15
27
19
32
23
TC kW
15.170
15.902
16.196
21
SC kW
11.618
12.184
14.248
TC kW
14.430
15.170
15.607
28
SC kW
11.505
12.088
14.057
TC kW
13.698
14.724
15.313
35
SC kW
11.339
11.888
13.952
TC kW
13.109
13.698
14.135
43
SC kW
11.392
11.627
13.604
TC kW
12.368
13.109
13.546
50
SC kW
11.139
11.531
13.464
Indoor Unit Temperature
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Air Temperature Entering
Outdoor Unit °C
21
15
27
19
32
23
TC kW
12.828
13.458
13.699
21
SC kW
9.310
9.765
11.479
TC kW
12.207
12.828
13.208
28
SC kW
9.234
9.699
11.337
TC kW
11.586
12.457
12.958
35
SC kW
9.111
9.547
11.252
TC kW
10.965
11.586
11.956
43
SC kW
9.073
9.348
10.996
TC kW
10.464
11.085
11.456
50
SC kW
8.979
9.291
10.892
Indoor Unit Temperature
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Dry Bulb °C
Wet Bulb °C
Air Temperature Entering
Outdoor Unit °C
21
15
27
19
32
23
TC kW
9.614
10.076
10.263
21
SC kW
7.308
7.665
8.971
TC kW
9.143
9.614
9.890
28
SC kW
7.235
7.610
8.843
TC kW
8.681
9.330
9.703
35
SC kW
7.135
7.482
8.779
TC kW
8.308
8.681
8.957
43
SC kW
7.171
7.318
8.560
TC kW
7.837
8.308
8.584
50
SC kW
7.007
7.254
8.469
TC = Total Cooling Capacity