16
Fig. 13 – Wiring Circuit for Brivis Classic Series Heaters with ICE
Using Brivis Programmable Thermostat
Contact Brivis Technical Support for information on superseded Brivis Heaters.
Fig. 14 – SHEILDED COMMUNICATION CABLE BETWEEN INDOOR AND OUTDOOR UNITS
Y
G
R
Electronic Thermostat
W
HCCA621
Fan Speed
G W R
EARTH
Rc
Electronic Control Module
Red LED
C Y
12AC
Fuse 2A
INDOOR UNIT ELECTRIC BOX
A1
A2
Indoor Unit
Electric Box
3 Core
Shielded
Communication cable