Service Manual 32 – Contour 3 Series, Profiler & Advance – Approved Issue 5 Printed 2/13/2014 11:50:17 AM
66
Cooler Operation:
(cont.)
Water Inlet Solenoid Operation
The Contour Cooler has a 240 Volt water inlet solenoid on the under side of the base,
at the high side of the roof.
The water inlet solenoid has a flexible hose attached with a filter inserted in the hose
connections at each end.
A 3/4" to 1/2" BSP nipple is provide for the installer for a convenient connection to the
hose.
The water inlet solenoid is assembled in a bracket to support the pipe connection and
the outlet discharge, which is direct to a fitting moulded into the Cooler base on the
high roof side.
The wiring loom to the water inlet solenoid is concealed under the base, and feeds
back into the service access compartment.
Note: The water inlet solenoid uses the water supply pressure to it's diaphragm in the
closing action of the valve.
Ensure the solenoid closes within 5 seconds of turning the 240 Volt power OFF to the
water inlet solenoid.
Dismantling
•
Turn OFF the water.
•
Unclip the solenoid from the housing.
•
Slide the assembly out to disconnect the water supply and wire loom. Care must
be taken when disconnecting the water supply as to not break the solenoid coil of
the body of the valve.
•
To access filter, remove the water supply hose, remove filter basket with pin nose
pliers.