7 181 465 347 (01.07)
8
Boiler service functions
6.8
Cycle time (hot water)
-
0 - 60 min
0 min
6.9
Duration (hot water)
-
0 - 30 min
1 min
7.0
Pump map (heating)
-
0 Pump step adjustable
1 Const. pressure high
2 Const. pressure
middle
3 Const. pressure low
4 Prop.pressure high
5 Prop.pressure low
4 Prop.
pres-
sure
high
7.1
Map pump step (heat.).
-
2 - 7
7
7.2
Antiblock. map pump.
-
off
on
on
7.3
Air purge mode
-
off
on autom. deaktivat.
permanent on
on
autom.
deaktiv
at./ off
7.4
Actual map pump step
1 - 8
-
-
7.5
Map pump load index
0 ... 255
-
-
7.6
Map pump type
0 .. 99
-
-
7.7
Output reduction
-
off
only in heating mode
only in hot water mode
in heat./hot water mode.
only in
heating
mode
8.5
Siphonfillprogram
-
on, boiler min.output,
on, adjust. min output,
off
on,
boiler
min.
output
9.2
Hot water on demand
-
off
on
on
9.3
GFA-Asic-error
00h - FFh
-
-
1)
The reset value depends on the code plug.
Text display message
Display
Range adjustable
from - to
Reset
Value
Table 1