7 181 465 347 (01.07)
6
Boiler service functions
3
Boiler service functions
3.1
Summary
Text display message
Display
Range adjustable
from - to
Reset
Value
0.0
Last fault
00 - FF
Clear only
0
0.1
Flow temp. sensor
0 - 99 °C
-
-
0.2
Hot water temp. sensor
0 - 99 °C
-
-
0.3
Stor. tank temp. sensor1
0 - 99 °C
-
-
0.4
Stor. tank temp. sensor2
0 - 99 °C
-
-
1.2
Code plug 8714411 XXX
0 - 255
-
-
1.5
Required flow temp.
0 - 99 °C
-
-
1.9
Module detection
no module detected
bus module
-
-
2.0
Operating mode
-
normal
Min
Max
normal
2.2
Pump switch mode
-
1 - 3
2
2.3
Stor. tank charge output
-
0 - 100%
100 %
2.4
Anti-cycle mode
-
0 - 15 min
3 min
2.5
Max. flow temperature
-
35 - 88 °C
88 °C
2.6
Switch.diff.flow temperature
-
0 - 30 °C
0 °C
2.7
Autom. anti-cycle mode
-
on
off
on
2.9
Actual output
0 - 100 %
-
-
3.0
Fan speed
0 - 255 U/s
-
-
3.3
Ionisations current
no
low
middle
high
-
-
3.4
Pump mode
-
0 - 3
0
1)
3.5
Pump blocking time
-
0 - 240 s
in 15-s increments
0 s
3.6
Software version
BF 11.XX
-
-
Table 1
Summary of Contents for ICC2 combi ZWBR 11-37 ICC2