1.9
Technical data
Units
ZWBR 8-30
Natural gas
ZWBR 11-30
Propane
ZWBR 11-37
Natural gas
ZWBR 14-37
Propane
Max. rated heat output net 40/30˚C central heating
Max. rated heat output net 50/30˚C central heating
Max. rated heat output net 80/60˚C central heating
kW
kW
kW
32.3
31.9
30.2
32.3
31.9
30.2
39.7
39.2
37.1
39.7
39.2
37.1
Max. rated heat input net
kW
30.5
30.5
37.5
37.5
Min. rated heat output net 40/30˚C
Min. rated heat output net 50/30˚C
Min. rated heat output net 80/60˚C
kW
kW
kW
9.5
9.4
8.2
12.7
12.6
11.0
12.9
12.8
11.4
16.2
16.1
14.3
Min. rated heat input net
kW
8.8
11.8
11.8
14.8
Max. rated heat output net, domestic hot water
kW
30.2
30.2
37.1
37.1
Max. rated heat input net, domestic hot water
kW
30.5
30.5
37.5
37.5
Maximum gas flow rate – After 10 minutes from lighting
Natural gas G20
(CVnet 34.02 MJ/m
3
)
m
3
/h
3.2
3.9
LPG
(CVnet 88 MJ/m
3
)
kg/h
2.2
2.7
Gas supply pressure
Natural gas G20
(CVnet 34.02 MJ/m
3
)
mbar
20
-
20
-
LPG
(CVnet 88 MJ/m
3
)
mbar
-
37
-
37
Expansion vessel
Charge pressure
bar
0.75
0.75
0.75
0.75
Total capacity
l
10
10
10
10
Hot water specifications
Hot water flow rate (factory setting)
l/min
8
8
8
8
Max. hot water flow rate
l/min
14.0
14.0
14.0
14.0
Outlet temperature range
˚C
40 - 60
40 - 60
40 - 60
40 - 60
Max. permissible water supply pressure
bar
10
10
10
10
Min. inlet pressure
bar
0.2
0.2
0.2
0.2
Specific flow rate
l/min
13.7
13.7
16.9
16.9
Flue
Flue gas temp. 80/60˚C, rated/min. load
˚C
78/57
78/57
87/58
87/58
Flue gas temp. 40/30˚C, rated/min. load
˚C
58/35
58/35
65/43
65/43
Residual delivery pressure
(inc. pressure drop in air intake duct)
Pa
90
90
100
100
CO
2
level at max. rated heat output
CO
2
level at min. rated heat output
%
%
9.4
9.2
11.0
11.0
9.2
9.2
11.0
11.0
NO
x
-class
5
5
5
5
SEDBUK figure, Band A
%
90.3
90.3
90.3
90.3
Condensate
Max. condensation rate (t
R
= 30˚C)
l/h
2.6
2.6
3.2
3.2
pH-value, approx.
4.8
4.8
4.8
4.8
General Data
Electrical power supply voltage
AC ... V
230
230
230
230
Frequency
Hz
50
50
50
50
Max. power consumption
W
156
156
161
161
Noise output level
dB(A)
39
39
41
41
Appliance protection ratingIP
X4D
X4D
X4D
X4D
Max. CH flow temperature
˚C
nom. 90
nom. 90
nom. 90
nom. 90
Max. permissible operating pressure (CH)
bar
2.5
2.5
2.5
2.5
Permissible ambient temperatures
˚C
0 - 50
0 - 50
0 - 50
0 - 50
Nominal capacity of appliance
l
3.75
3.75
3.75
3.75
Weight
kg
53
53
53
53
Table 2