background image

ENGLISH 

 

OPERATION MANUAL 

 

 
BRITEQ

®

 

2/12 

BT-SUNRAY 130R 

SAFETY INSTRUCTIONS: 

  To protect the environment, please try to recycle the packing material as much as possible. 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture. 

  To  avoid  condensation  to  be  formed  inside, allow  the  unit to  adapt to  the surrounding  temperatures  when  bringing  it 

into a warm room after transport. Condense sometimes prevents the unit from working at full performance or may even 
cause damages. 

  This unit is for indoor use only.  

 

Don’t  place  metal  objects  or  spill  liquid  inside  the  unit.  Electric  shock  or  malfunction  may  result.  If  a  foreign  object 
enters the unit, immediately disconnect the mains power. 

  Locate the fixture in a well ventilated spot, away from any flammable materials and/or liquids. The fixture must be fixed 

at least 50cm from surrounding walls. 

 

Don’t cover any ventilation openings as this may result in overheating.  

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

 

Maximum safe ambient temperature is 40°C. Don’t use this unit at higher ambient temperatures. 

  Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging and servicing. 

  Allow the device about 10 minutes to cool down before to start servicing. 

  Always unplug the unit when it is not used for a longer time or before to start servicing. 

  The  electrical  installation  should  be  carried  out  by  qualified  personal  only,  according  to  the  regulations  for  electrical 

and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the unit. 

  The  power  cord  should  always  be  in  perfect  condition.  Switch  the  unit  immediately  off  when  the  power  cord  is 

squashed or damaged. It must be replaced by the manufacturer, its service agent or similarly qualified persons in order 
to avoid a hazard. 

  Never let the power-cord come into contact with other cables! 

  This fixture must be earthed in order to comply with safety regulations. 

 

Don’t connect the unit to any dimmer pack. 

  Always use an appropriate and certified safety cable when installing the unit. 

  In order to prevent electric shock, do not open the cover. There are no user serviceable parts inside. 

 

Never

  repair  a  fuse  or  bypass  the  fuse  holder. 

Always

  replace  a  damaged  fuse  with  a  fuse  of  the  same  type  and 

electrical specifications! 

  In the event of serious operating problems, stop using the fixture and contact your dealer immediately. 

  The housing and the lenses must be replaced if they are visibly damaged. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

Important: 

Never  look  directly  into  th

e  light  source!  Don’t  use  the  effect  in  the  presence  of  persons  suffering  from 

epilepsy. 

 

 

CAUTION:

  To  reduce  the risk  of  electric  shock, do  not  remove  the  top 

cover.  No  user-serviceable  parts  inside.  Refer  servicing  to  qualified 
service personnel only. 

 

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the use or the 
presence  of  un-

insulated  “dangerous  voltage”  within  the  product’s  enclosure  that  may  be  of  sufficient 

magnitude to constitute a risk of electric shock. 

 

The  exclamation  point  within  the  equilateral  triangle  is  intended  to  alert  the  user  to  the  presence  of 
important operation and maintenance (servicing) instructions in the literature accompanying this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This symbol determines: the minimum distance from lighted objects. The minimum distance between light-
output and the illuminated surface must be more than x meters

 

 

CAUTION: 

Do not stare at operating lamp.  

May be harmful to the eyes. 

Summary of Contents for BT-SUNRAY 130R

Page 1: ......

Page 2: ......

Page 3: ...erent accessories included 2 compound eye lenses with beam angles 15 and 35 1 blinder glass authentic blinder look 1 Gel frame install optional CTO CTB COLOR filters 1 Glare shield anti glare and better beam Optional Barndoor available BT BARN 4 RAY series code 05527 Easy truss installation thanks to the fixing points for omega bracket small code 02677 Double bracket for easy ground installation E...

Page 4: ...shed or damaged It must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropriate and certified safety cable when installing the unit In order to pre...

Page 5: ...her units or a DMX controller The DMX input is also used to update the firmware of the projector see the upgrade instructions on our website 5 DMX OUT 3pin XLR connector used to daisy chain the projector with other units Remark a separate modification kit BT XLR3TO5 KIT order code 5523 is available to easily change the current 3pin XLR connectors into 5pin XLR connectors this takes only 2 minutes ...

Page 6: ...tings In addition a number of important settings are made via a DMX control channel Press the MENU button to enter the setup MENU Use the buttons to browse the MENU until the required function shows up Select the function with the ENTER button Use buttons to change the values Press the ENTER button to confirm the selected value ADDRESS Used to set the desired DMX address Use the buttons to browse ...

Page 7: ...ENU can be used at any time ON After a short time the setup MENU locks automatically the display shows LOCKED Unlock the display by pressing the buttons in this order ENTER Once the correct option shows on the display press the ENTER button to save it NO DMX BEHAVIOR Used to set how the projector reacts when the DMX signal suddenly disappears Use the buttons to browse the MENU until the required f...

Page 8: ...WW NO DMX mode BLACKOUT ST ALONE DIM Curve Square Square Dimmer Speed 100 440ms 100 440ms FAN Set Auto Silent Backlight 1 min 1 min AUTO LOCK MENU OFF OFF no DMX blink display ON OFF Temp C F Celcius Celcius FIRMWARE VERSION Used to show the current version of the firmware Use the buttons to browse the MENU until the required function shows up Select the function with the ENTER button the current ...

Page 9: ...he device should be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time The installations should be inspected every year by a skilled person to be sure ...

Page 10: ... addresses do not overlap Some general information on DMX The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units with a good quality balanced DMX cable Both XLR 3pin and XLR 5pin connectors are used however XLR 3pin is more popular Pin layout XLR 3pin Pin1 GND Pin2 Negative signal Pin3 Posit...

Page 11: ...ally Remember that each unit can use a different number DMX channels depending on the DMX mode you have selected in the MENU BLIND BLIND EXPO EXPO DMX FUNCTION REMARKS 8b 16b WW DTW VALUES 1 1 1 1 000 255 DIM WHITE coarse See control channel for RED SHIFT 2 000 255 DIM WHITE fine 2 3 000 255 DIM AMBER coarse RED SHIFT ACTIVE not used 4 000 255 DIM AMBER fine RED SHIFT ACTIVE not used 3 5 STROBE CH...

Page 12: ... prepare a complete DMX patch of all projectors on the DMX controller and send these data to all projectors at once More functions will be added later MAINTENANCE Make sure the area below the installation place is free from unwanted persons during servicing Switch off the unit unplug the mains cable and wait until the unit has been cooled down During inspection the following points should be check...

Page 13: ...95 Daisy chaining 15pcs 240Vac Protection class 1 IP rating IP65 outdoor DMX connections 5pin XLR male female 3pin XLR modification kit available DMX channels used 1 4 6 channels LEDs 135W warm white amber Color temperature CCT 1700K 3000K red shift effect CRI factor 97 R9 89 Lens beam angles 15 lens measured beam angle 19 field angle 29 35 lens measured beam angle 36 field angle 62 LED refresh ra...

Page 14: ...ENGLISH OPERATION MANUAL BRITEQ 12 12 BT SUNRAY 130R SPECIFICATIONS 2 ...

Page 15: ......

Page 16: ......

Reviews: