background image

ENGLISH 

 

OPERATION MANUAL 

 

 
BRITEQ

®

 

5/7 

BT-POWERJET 

5 CHANNEL MODE 

Channel 

Value 

Function 

Details 

CH 1 

000-009 

NO Fog output 

FOG 

010-255 

FOG ON 

CH 2 

000-255 

General Dimmer 

Master for LED groups 1 + 2 

CH 3 

000-009 

NO Strobe 

STROBE 

010-255 

Strobe (0-100%) 0 to 20Hz 

CH 4 

000-014 

Color Macro OFF (no output) 

LED group 1 

(LEDs around the nozzle) 

015-036 

Red 

037-058 

Green 

059-080 

Blue 

081-102 

Yellow 

103-124 

Light Blue 

125-146 

Purple 

147-168 

White 

169-255 

Colors change with speed control (slow to fast) 

CH 5 

000-014 

Color Macro OFF (no output) 

LED group 2 

015-036 

Red 

037-058 

Green 

059-080 

Blue 

081-102 

Yellow 

103-124 

Light Blue 

125-146 

Purple 

147-168 

White 

169-255 

Colors change with speed control (slow to fast) 

 

11 CHANNEL MODE  

Channel 

Value 

Function 

Details 

CH 1 

000-009 

NO Fog output 

FOG 

010-255 

FOG ON 

CH 2 

000-255 

General Dimmer 

DIMMER 

CH 3 

000-009 

NO Strobe 

STROBE 

010-255 

Strobe (0-100%) 

CH 4 

000-255 

Red (0-100%) 

only active when CH7 = 000-015

 

LED group 1 

CH 5 

000-255 

Green (0-100%) 

only active when CH7 = 000-015

 

CH 6 

000-255 

Blue (0-100%) 

only active when CH7 = 000-015

 

CH 7 

000-014 

Color Macro OFF 

(CH4+5+6 = active)

 

015-036 

Red 

037-058 

Green 

059-080 

Blue 

081-102 

Yellow 

103-124 

Light Blue 

125-146 

Purple 

147-168 

White 

169-255 

Colors change with speed control (slow to fast) 

CH 8 

000-255 

Red (0-100%) 

only active when CH11 = 000-015

 

LED group 2 

CH 9 

000-255 

Green (0-100%) 

only active when CH11 = 000-015

 

CH 10 

000-255 

Blue (0-100%) 

only active when CH11 = 000-015

 

CH 11 

000-014 

Color Macro OFF 

(CH8+9+10 = active)

 

015-036 

Red 

037-058 

Green 

059-080 

Blue 

081-102 

Yellow 

103-124 

Light Blue 

125-146 

Purple 

147-168 

White 

169-255 

Colors change with speed control (slow to fast) 

 

Summary of Contents for BT-POWERJET

Page 1: ...Other languages can be downloaded from WWW BRITEQ LIGHTING COM ENGLISH Operation Manual Version 1 0...

Page 2: ......

Page 3: ...cessary for the user to strictly follow the safety instructions and warnings in this user manual Any damage caused by mishandling is not subject to warranty The dealer will not accept responsibility f...

Page 4: ...the one stated on the rear panel of the unit The power cord should always be in perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the...

Page 5: ...machine ON OFF MENU SETTINGS READY TO WORK This message will be shown on the display as soon as the machine is ready to be used When the unit is just started up the heating element of the fogger need...

Page 6: ...hot and can cause serious burnings Make sure the fog liquid tank is not empty Always use good quality fog liquid to fill up the tank Close the tank immediately to prevent dirt to enter the reservoir...

Page 7: ...hannel Value Function Details CH 1 000 009 NO Fog output FOG 010 255 FOG ON CH 2 000 255 General Dimmer DIMMER CH 3 000 009 NO Strobe STROBE 010 255 Strobe 0 100 CH 4 000 255 Red 0 100 only active whe...

Page 8: ...p more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in...

Page 9: ...ity has been established and the relevant statements and documents have been deposited by the manufacturer This device has been designed to produce decorative effect lighting and is used in light show...

Page 10: ......

Reviews: