Cleaning the fogger: 

To  prevent  obstructions  in  the  heater,  pump  and  tubes,  the  fogger  should  be  cleaned  on  a  regular  basis: 
every 100h of continuous operation is a good reference. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 
This device has been designed to produce decorative effect lighting and is used in light show systems. 

 

Mains Input: 

220-240 V, 50/60 Hz 

Heater:

 

3200 Watt (or 1600W when half power mode is switched ON) 

Max. Power Consumption:

  

3500 Watt 

DMX Channels:

 

5 & 11 

Breaker: 

18A/250V 

Warm up time: 

7 min 

Max Output Height:

 

15m 

Tank size: 

3,8L 

Fluid Consumption:

  

7.5 ml/sec 

LEDs:

 

35x 9W RGB

 

Size:

 

490 x 340 x 260 mm  

Weight:

 

24 kg 

 

All the information is subject to change without prior notice 

You can download the latest version of this user manual on our website: 

www.briteq-lighting.com

   

 

Summary of Contents for BT-POWERJET

Page 1: ...Other languages can be downloaded from WWW BRITEQ LIGHTING COM ENGLISH Operation Manual Version 1 0...

Page 2: ......

Page 3: ...cessary for the user to strictly follow the safety instructions and warnings in this user manual Any damage caused by mishandling is not subject to warranty The dealer will not accept responsibility f...

Page 4: ...the one stated on the rear panel of the unit The power cord should always be in perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the...

Page 5: ...machine ON OFF MENU SETTINGS READY TO WORK This message will be shown on the display as soon as the machine is ready to be used When the unit is just started up the heating element of the fogger need...

Page 6: ...hot and can cause serious burnings Make sure the fog liquid tank is not empty Always use good quality fog liquid to fill up the tank Close the tank immediately to prevent dirt to enter the reservoir...

Page 7: ...hannel Value Function Details CH 1 000 009 NO Fog output FOG 010 255 FOG ON CH 2 000 255 General Dimmer DIMMER CH 3 000 009 NO Strobe STROBE 010 255 Strobe 0 100 CH 4 000 255 Red 0 100 only active whe...

Page 8: ...p more than 20cm if the main attachment fails The device should be well fixed a free swinging mounting is dangerous and may not be considered Don t cover any ventilation openings as this may result in...

Page 9: ...ity has been established and the relevant statements and documents have been deposited by the manufacturer This device has been designed to produce decorative effect lighting and is used in light show...

Page 10: ......

Reviews: