Bristan Joy care Installation Instructions And User Manual Download Page 5

4

5

Dial Control

Lever Control

JOYTHC85 W
JOYTHC95 W
JOYTHCK85 W
JOYTHCK95 W

JOYTHCKH85 W
JOYTHCKH95 W

1

2

3

4

5

6

7

8

9

joy care

joy care

joy care

Start / Stop

Product Features

2

1

1. Push Button Start/Stop Button

Press once to start the shower, press once again to stop 

the shower.
If audible sounds are enabled a single short beep will 

be heard when the button is pressed to turn the shower 

on. A single long beep will be heard when the button is 

pressed to turn the shower off. 

Stand-By Mode

 indicated by the light around the STOP/

START Button being on, denoting the shower is powered 

and ready to start.

2. Temperature Control

Adjustable temperature control.

Temperature Control Device

The Temperature Control Device will activate if the 

water inside the water heater gets too hot. The 

Temperature Control Device will switch off the power to 

the heating elements. Once the unit cools down to a safe 

temperature the elements will come on again and reheat 

the water within the water heater and the whole cycle will 

repeat itself until the temperature is manually reduced.

Warm-Up Indication

The light around the START/STOP Button will flash as the 

water heats up. Once the light stops flashing and stays 

on, the shower has reached your selected temperature 

and is ready to use. 
If audible sounds are enabled two short beeps will be 

heard once the shower is at the correct temperature.

Phased Shut Down & Indication

When the shower is turned off, water will continue to 

flow and the light around the START/STOP Button will 

flash for a short period while the heater cools down to 

approximately 30’C, before automatically turning off. 

This helps reduce limescale build-up.  
If audible sounds are enabled short beeps will be heard 

until the shower has turned off.

Maximum Temperature Setting (See page 17)

The shower enables the installer / user to set a 

maximum temperature. Once the maximum set 

temperature is achieved the temperature will not 

increase even if the temperature control dial is increased.

3. Temperature Setting Indicator

The Digital Display shows a number between 1 (cooler) 

and 9 (warmer) depending upon temperature (2) dial 

setting, and maximum temperature setting. 

Time Out Setting (See page 19)

The time out setting will ensure the shower turns off if 

the user fails to manually turn the shower off. The Time 

Out setting is pre set to 30 minutes but can be altered 

prior to installation to either 5, 10 or 20 minutes. The 

warning is three short beeps followed by a 2 second 

pause, repeated for a minute, before the shower times 

out. 
 

3

Need help?

 Give us a call on

 0844 701 6273

 and speak to one of our trained advisors.  

Summary of Contents for Joy care

Page 1: ...Stop Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave this document and the Large Print User Guide with the end user Installation I...

Page 2: ...ign with lots of features Bristan s electric shower collection has been designed to be easy to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards Th...

Page 3: ...k the flow of water from the showerhead by placing it smothering it on your hand or any other part of your body or foreign object Do not operate the shower if the water stops flowing during use or if...

Page 4: ...or use in Healthcare and special needs environments the factory set maximum temperature of 41 C must not be altered If the maximum set temperature is altered the shower will still continue to work how...

Page 5: ...he shower has reached your selected temperature and is ready to use If audible sounds are enabled two short beeps will be heard once the shower is at the correct temperature Phased Shut Down Indicatio...

Page 6: ...ttom Right hand side Bottom Rear bottom Product Fiche Model JOYTHC85 W JOYTHC95 W JOYTHCK85 W JOYTHCK95 W JOYTHCKH85 W JOYTHCKH95 W Declared Load Profile XS XS XS XS XS XS Water Heating Energy Efficie...

Page 7: ...st be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse...

Page 8: ...ithin the UK Network In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Do not turn on the electrical supply until the plumbing has been...

Page 9: ...ixed or sliding attachment hose retainer so that it can only discharge water at a point not less than 20mm above the spill over level of the bath or shower tray or other fixed appliance If a showerhea...

Page 10: ...from the wall and drill the wall to suit the wall fixings to be used Fixing Your Shower to the Wall Tips A piece of insulation or masking tape positioned where holes are to be drilled and before mark...

Page 11: ...entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear access Rear...

Page 12: ...5 6 Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page To top or...

Page 13: ...he pipe out of the elbow Turn on the water supply and inspect for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is design...

Page 14: ...to pages 7 and 8 Electrical Connection Entry Point Options Select the cable inlet option most suited to your situation Rear bottom left cable entry Rear bottom right cable entry Bottom left cable ent...

Page 15: ...ciently to allow cables to be directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using...

Page 16: ...ensuring that no cable insulation is trapped under the screws It must be metal to metal Loose connections can result in the cables overheating ensure all terminal screws are fully tightened The suppl...

Page 17: ...ns electricity supply to the shower Remove front cover Loosen the top and bottom fixing screws and pull front cover from the shower Locate the 8 way Dip switch on the control PCB This is found on the...

Page 18: ...DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 38 C ON ON ON 39 C OFF ON ON 40 C ON OFF ON 41 C BEAB CARE OFF OFF ON Factory Set 42 C ON ON OFF 43 C OFF ON OFF 44 C ON OFF OFF 45 C...

Page 19: ...wer On Single short beep Warm up complete Two short beeps Off Single long beep Phased shutdown Short beeps until shower shuts down Error Fault If an error code is displayed on the shower a continuous...

Page 20: ...staller Settings Audible Sounds ON Switch 4 ON Factory Set OFF Switch 4 OFF ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advi...

Page 21: ...ide the unit Rotate the temperature control knob to position 5 marked on the front cover Locate cover in position ensuring wiring is not trapped Secure using the 4 cover fixing screws supplied and fit...

Page 22: ...er installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall bracket Check that the rail is hang...

Page 23: ...missioning Purge Sequence will now resume a 10s no water flows b 30s running water c 10s pulsing water d 30s running water e Shower will display FC permanently on when the Commissioning Purge Sequence...

Page 24: ...ing the measuring equipment recorded in D1 4 or equipment to the same specification and with the appliance turned off check that a The water supply temperature is within the range 5 to 20 C b The term...

Page 25: ...next in service test can be deferred to 24 to 28 weeks after commissioning c If small changes e g 1 to 2 K in outlet water temperatures are recorded in both of these periods necessitating adjustment o...

Page 26: ...ys a delay of a few seconds between you selecting a temperature setting and the selected water temperature starting to flow If the user adjusts the Temperature Control the shower will stabilise to the...

Page 27: ...tate the spray head one way or the other until it clicks into the desired spray pattern Spray Jet spray Combination spray Note The spray head mode may need to be altered during winter conditions low f...

Page 28: ...with constant use means you may need to clean your showerhead once a week To ensure continued performance of your electric shower the showerhead needs to be regularly descaled Cleaning the Filter Per...

Page 29: ...ensure there are no restrictions to the shower Please refer to Cleaning the filter section on page 28 on how how to remove and clean the inlet filter and shower hose filters Once the service has been...

Page 30: ...kage Remove filter showerhead and clean Refer to Maintenance section on page 28 Outlet water temperature thermistor faulty Call Customer Services on 0844 701 6273 Other Fault Call Customer Services on...

Page 31: ...Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Guarantee Service Policy Replacement P...

Page 32: ...gm Pressure Relief Diaphragm x1 1 06 131 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O rings x3 1 07 131 406 S Inlet Elbow Ass Inlet Elbow x1 inc O ring x1 1 08 131 404 S F...

Page 33: ...33 Spare Parts 5 12 2 13 6 7 8 1 3 4 9 10 11 12 14 15 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors...

Page 34: ...Ass Matt Chrome 650mm Riser Rail x1 Riser Rail End Caps x2 1 03b 207041 012C 1M 1000mm Riser Rail Ass Chrome 1000mm Riser Rail x1 Riser Rail End Caps x2 1 04a 1625A0A Slider Handset Holder Slider Hand...

Page 35: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Page 36: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number FI ES JOY CARE Issue D5...