Bristan Joy care Installation Instructions And User Manual Download Page 22

22

Fixing Your Riser Rail to the Wall

Fitting the Riser Rail

Before proceeding with fitting the rail, identify each of the items 

supplied using the illustration on the right.
The Slider should not be removed from the rail during fitting. The 

underside of the slider has a button to release the slider and allows 

the height to be adjusted.
Slide the soap dish onto the bottom end of the rail. Position a wall 

bracket onto each end of the rail, ensuring the hole through the top 

of the rail lines up with the hole in a wall bracket.
Position the rail on the wall, bearing in mind the different heights 

of people likely to use the shower and the length of the hose when 

connected to the shower and passed through the retaining hole 

in the soap dish. Mark the wall to indicate the upper fixing screw 

position. 

Warning:

 Please check for any hidden pipes and cables before 

drilling holes in the wall.

Tips:

 

A piece of insulation or masking tape positioned where holes 

are to be drilled and before marking out the exact position 

for the fixing holes will help stop the drill bit from wandering, 

particularly on a tiled surface.
When working near a basin, bath or shower insert plug or cover 

waste to prevent losing small parts.
Take care not to drop tools/equipment into basin, bath or 

shower during shower installation.

Drill the wall at the marked fixing position to suit the wall fixings to 

be used, loosely fix the rail (with the large hole on the side shown) 

and wall bracket. Check that the rail is hanging vertically using a 

spirit level. 
Slide the lower wall bracket onto the rail and mark its required 

position onto the wall. 

Note: 

The lower wall bracket does not fix to the riser tube and can 

be positioned along the riser tube so as to cover either an existing 

riser hole in the wall or over a tile joint.
Remove the lower bracket from the rail and unscrew the upper 

bracket from the wall. Mark and drill the lower wall bracket fixing 

position and fix the bracket to the wall. Slide the rail down through 

the lower wall bracket and reattach the upper bracket.
Check that the rail is perfectly vertical and tighten the upper fixing 

screw. Insert end caps into the wall brackets at both ends of the rail.
When fitting the hose, it should pass through the hole of the soap 

dish. 

Note:

 The conical hose end and not the handset handle, fits into 

the slider. Ensure the washer is fitted between the hose and the 

handset handle. The slider moves more freely on the rail if gripped 

next to the rail, rather than at the handset.

Conical  

hose end

Washer

Need help?

 Give us a call on

 0844 701 6273

 and speak to one of our trained advisors.  

Note: The shower kit will vary 
depending on which model 
the end user has purchased.

Slider 

Slider release  

Handle

Hose  

retaining hole

Soap dish

Accessory  

hooks

Large hole

Summary of Contents for Joy care

Page 1: ...Stop Please keep this booklet for future reference Installer when you have read these instructions please ensure you leave this document and the Large Print User Guide with the end user Installation I...

Page 2: ...ign with lots of features Bristan s electric shower collection has been designed to be easy to fit and to use It has also been designed and tested in the UK to all of the relevant British Standards Th...

Page 3: ...k the flow of water from the showerhead by placing it smothering it on your hand or any other part of your body or foreign object Do not operate the shower if the water stops flowing during use or if...

Page 4: ...or use in Healthcare and special needs environments the factory set maximum temperature of 41 C must not be altered If the maximum set temperature is altered the shower will still continue to work how...

Page 5: ...he shower has reached your selected temperature and is ready to use If audible sounds are enabled two short beeps will be heard once the shower is at the correct temperature Phased Shut Down Indicatio...

Page 6: ...ttom Right hand side Bottom Rear bottom Product Fiche Model JOYTHC85 W JOYTHC95 W JOYTHCK85 W JOYTHCK95 W JOYTHCKH85 W JOYTHCKH95 W Declared Load Profile XS XS XS XS XS XS Water Heating Energy Efficie...

Page 7: ...st be connected to its own independent electrical supply It must not be connected to a ring main spur power socket or lighting circuit If you don t have a spare fuse way or the rating at the main fuse...

Page 8: ...ithin the UK Network In domestic installations you must ensure that the electrical supply and existing fuse board are adequately rated Do not turn on the electrical supply until the plumbing has been...

Page 9: ...ixed or sliding attachment hose retainer so that it can only discharge water at a point not less than 20mm above the spill over level of the bath or shower tray or other fixed appliance If a showerhea...

Page 10: ...from the wall and drill the wall to suit the wall fixings to be used Fixing Your Shower to the Wall Tips A piece of insulation or masking tape positioned where holes are to be drilled and before mark...

Page 11: ...entry Bottom right inlet entry Top left inlet entry Rear left inlet entry using a 15mm compression elbow not supplied where NO rear access is available Rear left inlet entry requiring rear access Rear...

Page 12: ...5 6 Inlet Entry Options The pipe work can enter the shower unit from 6 different positions Bottom left Bottom right Top left Rear left Rear right or Rear left using an elbow as shown on page To top or...

Page 13: ...he pipe out of the elbow Turn on the water supply and inspect for water leaks at the shower inlet Once inspected turn off the water supply Pressure Relief Device PRD A pressure relief device is design...

Page 14: ...to pages 7 and 8 Electrical Connection Entry Point Options Select the cable inlet option most suited to your situation Rear bottom left cable entry Rear bottom right cable entry Bottom left cable ent...

Page 15: ...ciently to allow cables to be directed to the terminal connection block within the unit Note When feeding cable through bottom entry points remove highlighted grey tab on pipe blanking cover if using...

Page 16: ...ensuring that no cable insulation is trapped under the screws It must be metal to metal Loose connections can result in the cables overheating ensure all terminal screws are fully tightened The suppl...

Page 17: ...ns electricity supply to the shower Remove front cover Loosen the top and bottom fixing screws and pull front cover from the shower Locate the 8 way Dip switch on the control PCB This is found on the...

Page 18: ...DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 38 C ON ON ON 39 C OFF ON ON 40 C ON OFF ON 41 C BEAB CARE OFF OFF ON Factory Set 42 C ON ON OFF 43 C OFF ON OFF 44 C ON OFF OFF 45 C...

Page 19: ...wer On Single short beep Warm up complete Two short beeps Off Single long beep Phased shutdown Short beeps until shower shuts down Error Fault If an error code is displayed on the shower a continuous...

Page 20: ...staller Settings Audible Sounds ON Switch 4 ON Factory Set OFF Switch 4 OFF ON DIP 1 2 3 4 5 6 7 8 ON DIP 1 2 3 4 5 6 7 8 Need help Give us a call on 0844 701 6273 and speak to one of our trained advi...

Page 21: ...ide the unit Rotate the temperature control knob to position 5 marked on the front cover Locate cover in position ensuring wiring is not trapped Secure using the 4 cover fixing screws supplied and fit...

Page 22: ...er installation Drill the wall at the marked fixing position to suit the wall fixings to be used loosely fix the rail with the large hole on the side shown and wall bracket Check that the rail is hang...

Page 23: ...missioning Purge Sequence will now resume a 10s no water flows b 30s running water c 10s pulsing water d 30s running water e Shower will display FC permanently on when the Commissioning Purge Sequence...

Page 24: ...ing the measuring equipment recorded in D1 4 or equipment to the same specification and with the appliance turned off check that a The water supply temperature is within the range 5 to 20 C b The term...

Page 25: ...next in service test can be deferred to 24 to 28 weeks after commissioning c If small changes e g 1 to 2 K in outlet water temperatures are recorded in both of these periods necessitating adjustment o...

Page 26: ...ys a delay of a few seconds between you selecting a temperature setting and the selected water temperature starting to flow If the user adjusts the Temperature Control the shower will stabilise to the...

Page 27: ...tate the spray head one way or the other until it clicks into the desired spray pattern Spray Jet spray Combination spray Note The spray head mode may need to be altered during winter conditions low f...

Page 28: ...with constant use means you may need to clean your showerhead once a week To ensure continued performance of your electric shower the showerhead needs to be regularly descaled Cleaning the Filter Per...

Page 29: ...ensure there are no restrictions to the shower Please refer to Cleaning the filter section on page 28 on how how to remove and clean the inlet filter and shower hose filters Once the service has been...

Page 30: ...kage Remove filter showerhead and clean Refer to Maintenance section on page 28 Outlet water temperature thermistor faulty Call Customer Services on 0844 701 6273 Other Fault Call Customer Services on...

Page 31: ...Modification or repair of this product by person s not authorised by Bristan will invalidate this guarantee This guarantee does not affect your statutory rights Guarantee Service Policy Replacement P...

Page 32: ...gm Pressure Relief Diaphragm x1 1 06 131 400 S Water Inlet Ass Inlet Elbow x1 Swivel Inlet Pipe x1 Filter x1 inc O rings x3 1 07 131 406 S Inlet Elbow Ass Inlet Elbow x1 inc O ring x1 1 08 131 404 S F...

Page 33: ...33 Spare Parts 5 12 2 13 6 7 8 1 3 4 9 10 11 12 14 15 Need help Give us a call on 0844 701 6273 and speak to one of our trained advisors...

Page 34: ...Ass Matt Chrome 650mm Riser Rail x1 Riser Rail End Caps x2 1 03b 207041 012C 1M 1000mm Riser Rail Ass Chrome 1000mm Riser Rail x1 Riser Rail End Caps x2 1 04a 1625A0A Slider Handset Holder Slider Hand...

Page 35: ...lease use this space to add any notes you or your installer may have regarding the plumbing system installation of this product Need help Give us a call on 0844 701 6273 and speak to one of our traine...

Page 36: ...Bristan Group Ltd Birch Coppice Business Park Dordon Tamworth Staffordshire B78 1SG Web www bristan com Email enquire bristan com A Masco Company Part Number FI ES JOY CARE Issue D5...

Reviews: