This function changes the displayed language. The ACR

®

 MiniPRO™ displays 

either  English or German (Deutsch). 

NOTE: This function requires a shut down and reboot. 

1.  Access the SYSTEM menu. 

2.  Touch LANGUAGE, SPRACHE button.. 

3.  Select Language or Cancel. 

4.  Press OK to shut down hot bonder. 

5.  Flip the red main power switch to the OFF position. The main power switch 

is  not illuminated when off. 

6.  Flip the red main power switch to the ON position. The main power switch is 

illuminated when on. 

7.  Software now displays desired language. 

Change Administrator Password: 

This function permanently changes the administrator password: 

Requires 

administrator password.

 

1.  Touch the SYSTEM tab at the top of the screen. 

2.  Touch the PASSWORD ADMINISTRATION button. 

3.  Touch the ENTER ADMINISTRATOR PASSWORD field. A keyboard screen 

appears. 

4.  Type your administrator password. Touch the ENTER button when 

complete. 

NOTE: Factory default password is “BHT”. 

5.  Touch the ENTER NEW PASSWORD field. A keyboard screen appears. 

6.  Type your new administrator password. Touch the ENTER button when 

done. 

7.  Touch the RE-ENTER NEW PASSWORD field. A keyboard screen appears. 

8.  Re-type your new administrator password. Touch the ENTER button when 

done. 

9.  Touch the UPDATE ADMIN PASSWORD button. 

NOTE: System is in administrator mode until the hot bonder is shut down. 

See Shut Down System on page 24 to shut down system. 

Delete All Program Passwords: 

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

26 

ACR

®

3 MiniPRO™ Hot Bonder 

This function deletes all program passwords stored in the ACR

®

3. 

Requires 

administrator password.

 

1.  Touch the SYSTEM tab at the top of the screen. 

2.  Touch the PASSWORD ADMINISTRATION button. 

3.  Touch the ENTER ADMINISTRATOR PASSWORD field. A keyboard screen 

appears. 

4.  Type your administrator password. Touch the ENTER button when 

complete. 

NOTE: Factory default password is “BHT”. 

5.  Touch the DELETE ALL PROGRAM PASSWORDS button. 

6.  Touch OK button to confirm. 

NOTE: System is in administrator mode until the hot bonder is shut down. 

See Shut Down System on page 24 to shut down system. 

Factory Settings: 

This function is for BriskHeat

® 

factory only. It sets up the initial parameters. 

CLEANING AND DECONTAMINATION

 

Clean only with a damp cloth and mild detergent, exterior only. No water should 
penetrate the enclosure. 

EQUIPMENT MAINTENANCE

 

Return to factory for repair, annual calibration, or maintenance. Contact factory at 
1-800-848-7673 (toll free, U.S. / Canada) or 614-294-3376 for complete details.  

Summary of Contents for ACR 3 MiniPRO Hot Bonder

Page 1: ...while Running 20 Change Program Password 20 System Menu 21 Save a Single Log File to USB Drive 21 Save All Log Files to USB Drive 22 Delete a Single Log File 22 Delete All Log Files 22 Save a Single...

Page 2: ...ilure to observe these warnings may result in electric shock risk of fire and personal injury or death Inspect hot bonder before use Do not use hot bonder if damaged Do not repair damaged or faulty ho...

Page 3: ...ply voltage fluctuations up to 10 of the nominal voltage Transient over voltages typically found on a Category II power source i e a lighting circuit Frequency 50 60Hz 20 amps maximum per zone Maximum...

Page 4: ...insert The connectors are keyed to prevent improper connections 3 Turn the locking ring clockwise 1 2 turn to lock the cord into place The cord must be fully inserted and locked for proper operation R...

Page 5: ...Version Number The newest version of the software can be found at www briskheat com Do not touch touchscreen with sharp objects or marking objects such as pens pencils markers etc These objects cause...

Page 6: ...n displays 5 Enter the necessary repair data or skip by pressing ENTER 6 To enter the repair data touch the data field to be entered 7 Using the keyboard on the data entry screen enter the required da...

Page 7: ...Corporation All rights reserved 14 ACR 3 MiniPRO Hot Bonder Alarms If all conditions are inside the programmed limits while a zone is running the zone tab is green If while running any condition exce...

Page 8: ...hen ramps down DUAL The hot bonder ramps once to a first set point holds for the programmed length of time ramps to a second set point holds for the programmed length of time then ramps down TRIPLE Th...

Page 9: ...uples Active thermocouples are indicated by a check mark in the check box next the corresponding thermocouple number Touch the check boxes to remove the check mark from the inactive thermocouples 16 P...

Page 10: ...1 Access the PROGRAM menu 2 Select the program to delete by touching the drop down menu for STORED PROGRAM NAME 3 Touch DELETE button to delete program 4 Touch YES to confirm BriskHeat Corporation Al...

Page 11: ...USB Drive This function saves all stored log files to a USB flash disk thumb drive This data can be transferred to a PC for analysis or archiving NOTE The ACR MiniPro Hot Bonder is capable of storing...

Page 12: ...programs in its internal memory 1 Access the SYSTEM menu 2 Touch LOAD PROGRAMS FROM USB DRIVE button 3 Insert USB flash drive thumb drive in USB port located on the operator console Touch OK button 4...

Page 13: ...NEW PASSWORD field A keyboard screen appears 8 Re type your new administrator password Touch the ENTER button when done 9 Touch the UPDATE ADMIN PASSWORD button NOTE System is in administrator mode un...

Page 14: ...under this warranty shall be limited to the repair or replacement at BriskHeat s option of any parts of the product which may prove defective under prescribed use and service following BriskHeat s exa...

Reviews: