background image

Instruction Manual 

 

You must read and understand this manual 
before installing, operating, or servicing this 
product. Failure to understand these 
instructions could result in an accident causing 
serious injury or death. 
Keep these instructions for future reference. 

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

ACR

®

3 MiniPRO™ Hot Bonder 

TABLE OF CONTENTS 

Safety Alert Symbol .............................................. 2 
Explanation of Symbols Used ............................. 2 
Important Safety Instructions .............................. 3 
Introduction .......................................................... 4 
Package Contents ................................................ 4 
Getting to Know Your ACR®MiniPRO ................. 5 
Specifications ....................................................... 6

 

Equipment Setup and Start-up ............................. 7

 

Power Input ................................................... 7 

Starting Up ......................................................7 

Heater Output Cord Attachment ..................... 7 

Temperature Sensor Attachment .................... 8 

Vacuum Hose Connect ....................................8 

Vacuum Venturi ................................................ 8 

Touchscreen Operating Instructions

 ....................9 

Operating Menu .............................................. 10

 

Starting a Program ....................................... 11 

Safely Shut Down .......................................... 12 
Save a Log File ............................................ 12 

Print a Snapshot .......................................... 12 

Hold a Program ............................................ 12 

Cancel a Program with a Fall ....................... 12 

Cancel a Program ........................................ 13 

View Plot ...................................................... 13 

Alarms ......................................................... 14 

Program Menu ................................................ 14

 

Write a New Program ................................... 15 

Edit an Existing Program.............................. 19 

Delete a Program ......................................... 19 

Edit an Existing Program while Running ....... 20 

Change Program Password ......................... 20 

System Menu .................................................. 21

 

Save a Single Log File to USB Drive ............ 21 

Save All Log Files to USB Drive .................... 22 

Delete a Single Log File ............................... 22 

Delete All Log Files ...................................... 22 

Save a Single Program File to USB Drive .... 23 

Save All Program Files to USB Drive ............ 23 

Load a Single Program File from USB Drive.23 

Load All Program Files from USB Drive ........ 24 

Shut Down System ....................................... 24 

Change System Date and Time .................... 24 

Change Language ......................................... 25 

Change Administrator Password .................. 25 

Delete All Program Passwords ..................... 26 

Factory Settings ........................................... 26 

Cleaning and Decontamination ......................... 26 
Equipment Maintenance .................................... 26 
Warranty .............................................................. 28 

 

SAFETY ALERT SYMBOL 

 

 

The symbol above is used to call your 
attention to instructions concerning  your 
personal safety. It points out  important 
safety precautions. It  means 

ATTENTION! Become Alert!  Your 

Personal Safety is involved!

”  Read 

the message that follows and  be alert to 
the possibility of personal  injury or 
death. 

 

Immediate hazards which WILL result 

in severe personal injury or death 

 

Hazards or unsafe practices which 

COULD result in severe personal 

injury or death 

 

Hazards or unsafe practices which 

COULD result in minor personal 

injury or property damage. 

SAVE THESE  

INSTRUCTIONS!

 

Additional copies 

of this manual are 

available upon 

request. 

Summary of Contents for ACR 3 MiniPRO Hot Bonder

Page 1: ...while Running 20 Change Program Password 20 System Menu 21 Save a Single Log File to USB Drive 21 Save All Log Files to USB Drive 22 Delete a Single Log File 22 Delete All Log Files 22 Save a Single...

Page 2: ...ilure to observe these warnings may result in electric shock risk of fire and personal injury or death Inspect hot bonder before use Do not use hot bonder if damaged Do not repair damaged or faulty ho...

Page 3: ...ply voltage fluctuations up to 10 of the nominal voltage Transient over voltages typically found on a Category II power source i e a lighting circuit Frequency 50 60Hz 20 amps maximum per zone Maximum...

Page 4: ...insert The connectors are keyed to prevent improper connections 3 Turn the locking ring clockwise 1 2 turn to lock the cord into place The cord must be fully inserted and locked for proper operation R...

Page 5: ...Version Number The newest version of the software can be found at www briskheat com Do not touch touchscreen with sharp objects or marking objects such as pens pencils markers etc These objects cause...

Page 6: ...n displays 5 Enter the necessary repair data or skip by pressing ENTER 6 To enter the repair data touch the data field to be entered 7 Using the keyboard on the data entry screen enter the required da...

Page 7: ...Corporation All rights reserved 14 ACR 3 MiniPRO Hot Bonder Alarms If all conditions are inside the programmed limits while a zone is running the zone tab is green If while running any condition exce...

Page 8: ...hen ramps down DUAL The hot bonder ramps once to a first set point holds for the programmed length of time ramps to a second set point holds for the programmed length of time then ramps down TRIPLE Th...

Page 9: ...uples Active thermocouples are indicated by a check mark in the check box next the corresponding thermocouple number Touch the check boxes to remove the check mark from the inactive thermocouples 16 P...

Page 10: ...1 Access the PROGRAM menu 2 Select the program to delete by touching the drop down menu for STORED PROGRAM NAME 3 Touch DELETE button to delete program 4 Touch YES to confirm BriskHeat Corporation Al...

Page 11: ...USB Drive This function saves all stored log files to a USB flash disk thumb drive This data can be transferred to a PC for analysis or archiving NOTE The ACR MiniPro Hot Bonder is capable of storing...

Page 12: ...programs in its internal memory 1 Access the SYSTEM menu 2 Touch LOAD PROGRAMS FROM USB DRIVE button 3 Insert USB flash drive thumb drive in USB port located on the operator console Touch OK button 4...

Page 13: ...NEW PASSWORD field A keyboard screen appears 8 Re type your new administrator password Touch the ENTER button when done 9 Touch the UPDATE ADMIN PASSWORD button NOTE System is in administrator mode un...

Page 14: ...under this warranty shall be limited to the repair or replacement at BriskHeat s option of any parts of the product which may prove defective under prescribed use and service following BriskHeat s exa...

Reviews: