background image

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

19 

ACR

®

3 MiniPRO™ Hot Bonder 



High Temperature Limit: 

allows the administrator to set a limit 

which any user will not be able to exceed while writing programs. 
This safety feature is used to protect the facilities equipment and  the 
items being repaired. This variable can only be changed in the 
program screen. Upon completing the high temperature limit change, 
clear out the administrator password before rebooting. 

Requires 

administrator password.

 

NOTE: This feature will change the high temperature limit in ALL 

programs/recipes. 

Edit an Existing Program:

 

This function makes changes to an existing program. 

Programs can be written or changed at any time even when the program is 
running.  Changes to an active program do not take place until the active zone 
is restarted.  For additional information see 

Edit an Existing Program While 

Running 

on page 20

.

 

1.  Access the PROGRAM menu 

2.  Select the program to edit by touching the drop down menu for STORED 

PROGRAM NAME. 

3.  Make changes to the following settings by touching the necessary field. 



Thermocouple source 

•   Shutdown alarm temperature 



Data logging interval 

•   Deviation alarm temperature 



Thermocouple settings 

•   Vacuum pressure high-limit & 

 

 

low-limit alarm settings 

4. Touch SAVE button to save changes. 

NOTE: The only parameter of a program that cannot be changed is the 

program name. 

Delete a Program: 

1.  Access the PROGRAM menu. 

2.  Select the program to delete by touching the drop down menu for STORED 

PROGRAM NAME. 

3.  Touch DELETE button to delete program. 

4.  Touch YES to confirm. 

© BriskHeat

®

 Corporation.  All rights reserved.

 

 

20 

ACR

®

3 MiniPRO™ Hot Bonder 

Edit an Existing Program While Running: 

Programs can be written or changed at any time even when the program is 
running.  Changes to an active program do not take place until the active 
zone is  restarted. 
1.  Change the program to the desired parameters by following the steps in 

Edit  an Existing Program 

on page 19. 

2.  Select the zone to be reset by touching either  

 

3.  In the zone operating screen, touch the HOLD button. 

4.  Press the RUN button.  The cure step field returns to the previous active 

step of the program and the printer, if active, prints out the new program. 

NOTE: Changes to completed portions of a running program does not take 

effect  until the next time the program is ran.  For example, if 
changes are being made  to step one of a two-step program and the 
program has already started into the  second step, the changes does 
not take place until the next time the program is  ran. 

Change Program Password: 

This function changes a program password. You must know the current 
password. If current password is not known, refer to the SYSTEM menu 
section  of this manual for assistance. 
 

1.  Access the PROGRAM menu. 

2.  Touch the STORED PROGRAM NAME field. Select the program to change 

password protection. 

3.  Touch the CHANGE PASSWORD button. 

4.  Enter all required password information in the provided fields on screen. 

Touch OK button when finished. 

Summary of Contents for ACR 3 MiniPRO Hot Bonder

Page 1: ...while Running 20 Change Program Password 20 System Menu 21 Save a Single Log File to USB Drive 21 Save All Log Files to USB Drive 22 Delete a Single Log File 22 Delete All Log Files 22 Save a Single...

Page 2: ...ilure to observe these warnings may result in electric shock risk of fire and personal injury or death Inspect hot bonder before use Do not use hot bonder if damaged Do not repair damaged or faulty ho...

Page 3: ...ply voltage fluctuations up to 10 of the nominal voltage Transient over voltages typically found on a Category II power source i e a lighting circuit Frequency 50 60Hz 20 amps maximum per zone Maximum...

Page 4: ...insert The connectors are keyed to prevent improper connections 3 Turn the locking ring clockwise 1 2 turn to lock the cord into place The cord must be fully inserted and locked for proper operation R...

Page 5: ...Version Number The newest version of the software can be found at www briskheat com Do not touch touchscreen with sharp objects or marking objects such as pens pencils markers etc These objects cause...

Page 6: ...n displays 5 Enter the necessary repair data or skip by pressing ENTER 6 To enter the repair data touch the data field to be entered 7 Using the keyboard on the data entry screen enter the required da...

Page 7: ...Corporation All rights reserved 14 ACR 3 MiniPRO Hot Bonder Alarms If all conditions are inside the programmed limits while a zone is running the zone tab is green If while running any condition exce...

Page 8: ...hen ramps down DUAL The hot bonder ramps once to a first set point holds for the programmed length of time ramps to a second set point holds for the programmed length of time then ramps down TRIPLE Th...

Page 9: ...uples Active thermocouples are indicated by a check mark in the check box next the corresponding thermocouple number Touch the check boxes to remove the check mark from the inactive thermocouples 16 P...

Page 10: ...1 Access the PROGRAM menu 2 Select the program to delete by touching the drop down menu for STORED PROGRAM NAME 3 Touch DELETE button to delete program 4 Touch YES to confirm BriskHeat Corporation Al...

Page 11: ...USB Drive This function saves all stored log files to a USB flash disk thumb drive This data can be transferred to a PC for analysis or archiving NOTE The ACR MiniPro Hot Bonder is capable of storing...

Page 12: ...programs in its internal memory 1 Access the SYSTEM menu 2 Touch LOAD PROGRAMS FROM USB DRIVE button 3 Insert USB flash drive thumb drive in USB port located on the operator console Touch OK button 4...

Page 13: ...NEW PASSWORD field A keyboard screen appears 8 Re type your new administrator password Touch the ENTER button when done 9 Touch the UPDATE ADMIN PASSWORD button NOTE System is in administrator mode un...

Page 14: ...under this warranty shall be limited to the repair or replacement at BriskHeat s option of any parts of the product which may prove defective under prescribed use and service following BriskHeat s exa...

Reviews: