© BriskHeat
®
Corporation. All rights reserved.
19
ACR
®
3 MiniPRO™ Hot Bonder
High Temperature Limit:
allows the administrator to set a limit
which any user will not be able to exceed while writing programs.
This safety feature is used to protect the facilities equipment and the
items being repaired. This variable can only be changed in the
program screen. Upon completing the high temperature limit change,
clear out the administrator password before rebooting.
Requires
administrator password.
NOTE: This feature will change the high temperature limit in ALL
programs/recipes.
Edit an Existing Program:
This function makes changes to an existing program.
Programs can be written or changed at any time even when the program is
running. Changes to an active program do not take place until the active zone
is restarted. For additional information see
Edit an Existing Program While
Running
on page 20
.
1. Access the PROGRAM menu
2. Select the program to edit by touching the drop down menu for STORED
PROGRAM NAME.
3. Make changes to the following settings by touching the necessary field.
Thermocouple source
• Shutdown alarm temperature
Data logging interval
• Deviation alarm temperature
Thermocouple settings
• Vacuum pressure high-limit &
low-limit alarm settings
4. Touch SAVE button to save changes.
NOTE: The only parameter of a program that cannot be changed is the
program name.
Delete a Program:
1. Access the PROGRAM menu.
2. Select the program to delete by touching the drop down menu for STORED
PROGRAM NAME.
3. Touch DELETE button to delete program.
4. Touch YES to confirm.
© BriskHeat
®
Corporation. All rights reserved.
20
ACR
®
3 MiniPRO™ Hot Bonder
Edit an Existing Program While Running:
Programs can be written or changed at any time even when the program is
running. Changes to an active program do not take place until the active
zone is restarted.
1. Change the program to the desired parameters by following the steps in
Edit an Existing Program
on page 19.
2. Select the zone to be reset by touching either
3. In the zone operating screen, touch the HOLD button.
4. Press the RUN button. The cure step field returns to the previous active
step of the program and the printer, if active, prints out the new program.
NOTE: Changes to completed portions of a running program does not take
effect until the next time the program is ran. For example, if
changes are being made to step one of a two-step program and the
program has already started into the second step, the changes does
not take place until the next time the program is ran.
Change Program Password:
This function changes a program password. You must know the current
password. If current password is not known, refer to the SYSTEM menu
section of this manual for assistance.
1. Access the PROGRAM menu.
2. Touch the STORED PROGRAM NAME field. Select the program to change
password protection.
3. Touch the CHANGE PASSWORD button.
4. Enter all required password information in the provided fields on screen.
Touch OK button when finished.