background image

1

WE WANT YOU TO USE YOUR CONVERSION KIT FOR YOUR GRILL AS SAFELY AS 

POSSIBLE. THE PURPOSE OF THIS SAFETY ALERT SYMBOL 

 IS TO ATTRACT THE 

ATTENTION TO POSSIBLE HAZARDS AS THE GRILL IS CONVERTED AND USED AS A 

NATURAL GAS GRILL. WHEN YOU SEE THE SAFETY ALERT SYMBOL 

 PAY CLOSE 

ATTENTION TO THE INFORMATION WHICH FOLLOWS! 

 

 READ ALL SAFETY WARNINGS AND INSTRUCTIONS CAREFULLY

BEFORE CONVERTING AND OPERATING YOUR GRILL.

IMPORTANT SAFETY WARNINGS

1.  Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance.

2.  An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance.

WARNING

This conversion kit shall be installed by a professional service technician in accordance with the manufacturer’s 
instructions as specified by the codes and requirements of the authority having jurisdiction. The information in these 
instructions must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury 
or death. The qualified service agency performing this conversion assumes responsibility for the proper conversion 
of the appliance of this kit. 

WARNING

IF YOU SMELL GAS:

1.  Shut off gas to the appliance.

2.  Extinguish any open flame.

3. Open 

Lid.

4.  If odor continues, keep away from appliance and immediately call your gas supplier or your fire department.

DANGER

Failure to follow the instructions as written, or installation by other than a trained 

professional, will void all manufacturing warranties.

Installer Company or Service Name:__________________________________________________

Technician Name:     _______________________________     Installation Date:__________________

Model Number: _________________________________

Serial Number:__________________________________     Date Purchased:__________________

IMPORTANT: Fill out product record information below.

Summary of Contents for Select 810-6680-S

Page 1: ...ARNINGS AND INSTRUCTIONS ARE IGNORED READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS IN THIS MANUAL TO AVOID PERSONAL INJURY INCLUDING DEATH OR PROPERTY DAMAGE WARNING ADVERTENCIA SE PUEDE PRODUCIR UNA...

Page 2: ...ents of the authority having jurisdiction The information in these instructions must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death The qu...

Page 3: ...area FOR COVERS ACCESSORIES AND OTHER PRODUCTS PLEASE VISIT US ONLINE AT FOR OUTDOOR USE ONLY DO NOT operate indoors or in an enclosed area such as a garage shed or breezeway Use your grill OUTDOORS...

Page 4: ...lean on the side burner shelf Keep children and pets away from hot grill DO NOT allow children to use or play near this grill DO NOT leave the grill unattended while in use DO NOT allow the gas hose...

Page 5: ...Pcs PARTS CONTENTS ASSEMBLY INSTRUCTIONS YOU MUST BE A PROFESSIONAL SERVICE TECHNICIAN TO CONVERT THIS GRILL READ ALL SAFETY WARNINGS ASSEMBLY INSTRUCTIONS CAREFULLY BEFORE ASSEMBLING OR OPERATING TH...

Page 6: ...ench to hold the gas manifold connection secure use a 3 4 wrench to loosen the hose connection nut Replace existing LP hose regulator assembly with natural gas 10 hose assembly Tighten the connection...

Page 7: ...nt panel Repeat this step for all burner valves in your grill Note The Sear X burner has two LP gas valve orifices Step 5 The fryer burner orifice is located beneath the fryer burner side table To all...

Page 8: ...pre installed Make sure the pre installed stop plate is seated properly Replace Sear X control knob when finished Step 8a Carefully replace all burners making sure burner openings slide over valve no...

Page 9: ...naps forward locking plug into socket Be sure to leak test these connections prior to use Pipe nipple Quick disconnect coupling Plug Push sleeve back to attach Sleeve Socket Natural gas supply Natural...

Page 10: ...l is still hot DANGER WHEN TO PERFORM A LEAK TEST After assembling or converting your natural gas grill and before lighting for the first time even if purchased fully assembled Any time the gas compon...

Page 11: ...nnection to hose Sear burner valve stem cap The full length of gas supply hoses Quick disconnect coupler 7 Check each place listed A E for growing bubbles which indicates a leak Large leaks may not be...

Page 12: ...t Flame should be a Blue Yellow color between 1 2 when burner is on HIGH WARNING Property damage bodily harm severe burns and death could result from failure to follow these safety steps These steps s...

Page 13: ...escritas dadas aqu se ignoran o una persona que no sea un profesional capacitado instala el aparato toda garant a del fabricante quedar anulada ADVERTENCIA Este equipo de conversi n deber ser instala...

Page 14: ...ice esta parrilla en interiores o lugares cerrados como cocheras cobertizos o pasadizos techados abiertos Use su parrilla AFUERA en un lugar bien ventilado lejos de viviendas u otros edificios para ev...

Page 15: ...aire de combusti n o ventilaci n Nunca coloque un peso mayor de 15 libras 6 8 kg sobre el quemador lateral NO se recargue en el anaquel del quemador lateral Mantenga a ni os y mascotas lejos de la par...

Page 16: ...de 1 25 mm x 2 Pzs VERDE Orificio de la V lvula de 1 35mm x 2 Pzs ROJO 1 35mm 1 51mm Orificio de la V lvula de 1 51 mm x 1 Pz AZUL L S Esta parrilla se ha convertido a gas natural Etiqueta del Equipo...

Page 17: ...una llave de tuercas de 3 4 para aflojar la tuerca de conexi n de la manguera Reemplace el ensamblado manguera regulador para gas LP existente con el ensamblado de la manguera de 10 para gas natural A...

Page 18: ...mador Sear X tiene dos orificios de v lvula de gas LP Paso 5 El orificio del quemador lateral est localizado debajo de la mesa lateral del quemador Para permitir movimiento remueva las tuercas arandel...

Page 19: ...nar vuelva a colocar la perilla de control de Sear X en su lugar Paso 8a Con cuidado reemplazca cada quemador fij ndose que las aberturas de los quemadores se deslicen sobre las boquillas de las v lvu...

Page 20: ...tap n en el recept culo No se olvide realizar la prueba de detecci n de fugas en estas conexiones antes del uso Tubo Corto Enroscado Acoplamiento de Desconexi n R pida Tap n Empuje el manguito hacia...

Page 21: ...LIZAR UNA PRUEBA DE DETECCI N DE FUGAS Tras haber ensamblado o convertido su parrilla para usarla con gas natural y antes de encenderla por primera vez incluso si la compr totalmente ensamblada Cada v...

Page 22: ...e cada lugar enumerado A E para ver si salen burbujas que indicar an una fuga Es posible que las fugas grandes no se detecten por medio de burbujas sino que produzcan un sonido de r faga u olor a gas...

Page 23: ...e instrucci n contenida en las secciones anteriores de este manual Nota Observe la flama encendida debe tener una altura entre 1 y 2 pulgadas cuando el quemador est en posici n ALTO y ser de color azu...

Page 24: ...SPECIFIC LEGAL RIGHTS AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE WARRANTY Las autorizaciones de Brinkmann Corporation al comprador original que equipo universal de conversi n d...

Reviews: