![Brink Air Comfort Installation Regulations Download Page 7](http://html.mh-extra.com/html/brink/air-comfort/air-comfort_installation-regulations_2812493007.webp)
3 Version
3.1 Technical information
3.1.1 Air Comfort
Specification
Value
Supply voltage [V/Hz]
230/50
Dimensions (l x w x h) [mm]
676 x 640 x 429
Weight [kg]
40
Filter class
G3
Water connection (Ø) [mm]
22
Water capacity exchanger [l]
2
Water range [°C]
45/35
Air suction temperature [°C]
18
Maximum operating pressure exchanger [bar]
16
Nominal
Maximal
Air displacement [m
3
/h]
400
450
Permissible duct resistance design conditions [Pa]
100
126
Power consumption [W]
55
72
Sound power - box emission [db(A)]
51.1
53.3
Sound power - duct "to home" [db(A)]
59.3
62.9
Heating capacity [kW]
2.6
2.8
Water capacity [l/h]
225
249
Water pressure head [kPa]
1.47
1.78
3.1.2 Theoretical maximum head of appliance
Resistance of
duct system
[Pa]
Flow rate [m
3
/h]
Air Comfort 614788-B
Brink / 7